Providing and fitting of Oxygen flowmeters, Oxygen points, Suction points and Suction Jars at Triage and other locations of Govt. SMHS Hospital, Srinagar
2023_PWDJK_213259_1
MHCHD/TS /2023-24/17/e-tendering dt24-05-2023
Open Tender
Miscellaneous Works
Item Wise
5 days
Govt SMHS Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹100
Executive Engineer MHCHD, Srinagar
₹1,100
12 Jun 2023
24 May 2023
10 Jun 2023
24 May 2023
10 Jun 2023
25 May 2023
Amount
Providing, fitting and testing of ward vacuum units(600 ml) complete with suction regulator and compatable probe. The ward vacuum units of 600 ml capacity shall be designed for minimum servicing and high efficiency. The body shall house and ON/OFF knob, regulation knob, vacuum gauge graduated in mili bars. the jar of the vacuum unit shall be transparent made of polycarbonate, unbreakable to the temperature of 134 degree centigrate. the units shall be provided with fluid control trap (safety) fitted on the unit and shall automatically and efficiently shut off vacuum fully, preventing the transfer of liquid to the vacuum regulator, pipe line and pump. The vacuum units are to be fitted on walls with the help of brackets.The job shall be inclusive of high pressure vacuum pipe of lengtyh not less than 1metre/job.
Dismounting of the old malfunctioning of wall suction points, Providing, fitting and testing of self sealing valve assembly (front loaded double locking) including cover for suction supply. The valve shall be installed on the wall with its inlet connected to the copper tubing carrying suction pipe by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The valve shall be non-interchangeable, self sealing, quick-connect gas outlet for Suction suitable for head wallunits/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen and compatible probe. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings complete in all respects.
Dismounting of the old malfunctioning of wall oxygen points, Providing, fitting and testing of Oxygen self sealing valve-assembly (front loaded double locking) including cover for oxygen supply. The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings'complete in all respects. (The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units. The front facia of valves shall be non interchangeable and Gas color coded
IMPERIAL SOLUTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .