Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹40.7 L+₹97,014.50 (2.44%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹42.0 L+₹2.2 L (5.59%)Rejected-Finance SOUTH CANEL PAR PO PANAGARH BAZAR DISTT PASCHIM BARDWAN WB PIN 713148 | PANAGARH BAZAR | PASCHIM BARDWAN | WEST BENGAL | 713148 | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹44.0 L+₹4.2 L (10.5%)Rejected-Finance | L4 | Rejected-Finance Higher rate quoted | |
| 5 | L5₹45.1 L+₹5.3 L (13.3%)Rejected-Finance VILL BONOGRAM PO RANDIA P S BUDBUD DIST BURDWAN PIN 713120 WB | BURDWAN | BURDWAN | WEST BENGAL | 713120 | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
22 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_471170_1
8400-671/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D, Cat a (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹99,000
Yes
18 Nov 2021
27 Aug 2021
24 Sept 2021
27 Aug 2021
22 Sept 2021
9 Sept 2021
60 days
Amount
Surface excavation n.exc. 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed.
Excavation over area ,not exc 1.5 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.5 Cum and getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making surface good ,complete all as specified and as directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) of any thickness incl ridges hips valleys as in roof coverings complete all as specified and directed.
M&L for Pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified ,complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Dimantling of wall and ceiling boards (fibre, pulp, insulation boards etc) any thickness including cover fillets,complete all as specified and directed.
Supply and fix anodised aluminium snap grid frame work for false ceiling with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including 4 mm thick pre-painted decorative Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws ,complete all as specified and directed
Supply and fix wire netting of galvanised steel wire 0.71 mm dia and 25mm size of mesh fixed with tinned tack or wire staples, complete all as specified & as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises , complete all as specified and directed.
M&L for non skid ceramic tiles, coloured, joint free type, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layers of cement mortar (1:4), complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE.
All as per item No 14.00 mentioned here-in-above but in vertical surface as in skirting over 10mm thick rendering in cement mortar (1:4) , complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE
M&L for non skid ceramic tiles, coloured, joint free type, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layers of cement mortar (1:4), complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE.
M&L for glazed ceramic tiles (300x200x7mm thick), coloured, on vertical surface such as skirting, dado, risers etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in cement mortar (1:4), complete all as specified & directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE.
M&L for dark shed coloured vitrified ceramic tiles (joint free) 10 mm thick (Square/Rectangular) area of each tile not exceeding 0.36 sqm on vertical surface such as skirting, dado, risers etc set over and including 15 mm thick rendering cement mortar (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE.
M&L for factory made heavy duty coloured designer non skid ceramic tiles of size 300x300x10mm thick, coloured in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar (1:4), complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE.
M&L for granite (of any type) tiles 20 mm thick machine cut bedding and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) including polishing , complete all as directed and specified. Note: Design, shade and pattern of fixing of granite shall be as directed and approved by GE.
M&L for granite (of any type) tiles 20 mm thick machine cut in skirting/ dado and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 10mm thick backing coat or rendering layer in cement mortar (1:3) including polishing ,complete all as directed and specified. Note: Design, shade and pattern of fixing of granite shall be as directed and approved by GE
M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 15 mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified and directed. Note: Design, shade and pattern of fixing of kota stone shall be as directed and approved by GE.
M & L for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed. Note: Design, shade and pattern of fixing of kota stone shall be as directed and approved by GE
Demolition of cement concrete (unreinforced) in ground floors and paving n. exc 15 cm thickness below or above ground level, complete all as specified and directed.
Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M & L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in cement mortar (1:6 ) complete all as specified and directed.
M & L for brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6) ,complete all as specified and directed.
M&L for brick work with flyash bricks straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) on wall surface and finishing even and fair , complete all as specified and directed.
Material and labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with water proofing compound on wall and finishing fair and even , complete all as specified and directed. Note: WPC shall be measured and paid under separate item.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) on wall surface and finishing even and fair, complete all as specified and directed
Supply only integral water proofing compound.
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips, complete all as specified & directed
Material and Labour for TMT bar 6mm to 8mm dia cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips, complete all as specified & directed
M&L for hard drawn steel wire fabric, of weight nexc 4kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement, complete all as specified and directed
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip, complete all as specified and directed
All as per Item No 37.00 mentioned here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders,complete all as specified and directed.
M&L for M-30 Design mix using 20mm stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret ,complete all as specified and directed. Note:-contractor shall submit test report before execution of work.
M&L for M-30 Design mix using 20mm stone aggregate Columns, pillars, piers, posts and struts ,complete all as specified and directed. Note :- contractor shall submit test report before execution of work.
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter fair finished flat surfaces ,complete all as specified & directed
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed.
Use and waste of formwork for rough finished surface of concrete (flat surface) to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed.
M&L for PCC (1:3:6), type C2, using 40 mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) , complete all as specified & directed
M&L for sand filling under floors or in foundation including watering and consolidation , complete all as specified and directed.
M & L for machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade with grey cement and pigment complete all as specified and directed. Note: Design, shade and pattern of fixing of paver block shall be as directed and approved by GE.
M&L for moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & directed.
M&L for hardcore of broken stone or boulders of gauge nexc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified & directed.
M&L for hardcore of broken stone or boulders of gauge exc 63mm but n exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
Materials and Labour for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Materials and Labour for plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6, type C-1, (using 20mm graded stone aggregate) as in plinth courses ,string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs ,complete all as specified & directed.
M&L for 75mm thick PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in sub base of floor/paving etc ,complete all as specified and directed.
M&L for 150mm thick PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in sub base of floor/paving etc ,complete all as specified and directed.
Materials and Labour for 100 mm thick plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in sub base in floor/paving/hardstanding ,complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in sub base of floor/paving etc , complete all as specified and directed.
Material and labour for providing 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection and finished the surface even & smooth without using extra cement, complete all as specified and directed.
Material and labour for providing PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in surface channels and drain, complete all as specified and directed.
Materials and Labour for 100 mm thick plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floor finishing smooth and even without using extra cement,complete all as specified and directed.
M&L for PCC(1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stop rounded complete all as specified and directed.
M&L for PCC 1:2:4 type B 0 using (12.50 mm graded stone aggregate) as in coping, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.,complete all as specified and directed.
M&L for applying two coats of distemper oil imulsion over a coat of chalk whiting including preparation of newly plastered surfaces, complete all as specified and directed.
M&L for applying two coats of distemper oil imulsion over a coat of chalk whiting after complete removal of existing treatment complete all as specified and directed.
M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new or previously untreated surfaces complete all as specified and directed.
All as per item No 65.00 mentioned here-in-above but after complete removal of existing treatment ,complete all as specified and directed.
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm),complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint ,complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Taking down chowkats or frames with shutter w/o taking off shutter from the frame n exc 1.5 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed.
S&F 3 track sliding anodized aluminium glazed window shutter with frame with the following specification all as specified & directed. (a) Window frame 3 track of size 95mmx25mmx1.5mm thick (b) Stiles and rails of size 35mmx25mmx1.5mm (c) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangement for 02 Nos glazed shutter (d) Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples incl. aluminium handles with necessary locking arrangement for 01 No gauzed shutter Note : Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive.
Materials and Labour for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Grade E-165, complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St-240 complete all as specified and directed.
Taking down carefully copper /aluminium point wiring (light, fan, socket or power) completer, fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc removing materials to store for keetping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls/floors and reuse the serviceable fittings under respective items complete all as specified and directed.
Material and labour for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers or modular cover plate with frame of suitable size and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No 76.00 mentioned here-in-above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
All as per item No 76.00 mentioned here-in-above but 5 Amp socket on same board with other switches. complete all as specified and directed.
Material and labour wiring for socket out let 3 pin ,15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including modular pressed steel terminal switch boxes of different module, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers or modular cover plate with frame of suitable size and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc, complete all as specified and directed.
S&F switch modular type 6 Amp one way, 1 module, single phase complete all as specified and directed.
S&F switch modular socket 6 Amp 2/3pin combined , 2 module, single phase complete all as specified and directed.
S&F switch modular switch socket combination 16A , 6 pin, 3 module ,complete all as specified and as directed
S&F fan regulator modular stepped type 120 W 2 module . complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings, complete all as specified and directed.
Supply and fix in repair submain two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
Supply and fixing in repair Bldg security light fittings 25 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size, complete all as specified.and directed.
Supply and fix in repair 18 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and as directed
S&F in repair recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection, complete all as specified and directed.
Supply and fix in repair Vertical distribution board double door TPN 4 way with IP 43 multiphase outgoing suitable for mounting 100 Amps as incomer with Bus bars, Neutral links complete with all accessories complete all as directed.
Supply and fix in repair epoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fix in repair MCCB of 4 pole , 415volts of capacity 100 Amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting including necessry connection complete all as specified and directed.
Supply and fix in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fix in repairs MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply & fixing metallic Exhaust ventilation fan of sweep 450 mm sweep, 230volt AC complete with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with twin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed and testing on completion.
Taking down of ceiling fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan ,complete all as specified and directed.. (Note : Accessories such as split pin and jam nut shall be measured and paid under coated rate.).
M & L for painting of ceiling fans upto 1400mm sweep carefully, dismantling fan blades and paint with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as specified and directed.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts cross sectional area 70Sqmm x 3.5 core in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable Route Indicator made of metal of height 300mm above GL duly written ''LT CABLE'' to be fixed on every 30 mtr distance with pcc (1:3:6), 150 mm below the GL ,cost of indicator and pcc to be considered in this item rate.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured). Note :- Punned thickness 18 cm shall only be considered for payment.
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed.
Supply and fixing/laying 50mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed.
M/S S M ENTERPRISE
Hooghly Construction Co.
SUPARNA TRADING
M/s S A TRADING
ROY ENTERPRISE
NATIONAL CONSTRUCTION CO
BABY ENGINEERING ELECTRICAL MECHANICAL STORES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .