Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L1 | Accepted-AOC Accepted being Lowest Bidder | |
| 2 | L2₹44.0 L+₹3.7 L (9.32%)Rejected-AOC | L2 | Rejected-AOC Rejected being other than Lowest Bidder | |
| 3 | L3₹44.8 L+₹4.5 L (11.3%)Rejected-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L3 | Rejected-AOC Rejected being other than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S A P CONSTRUCTION L1 | Unnati Engineers L3 | MTR GROUP & COMPANY L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 451.71 | Cum | 80 ₹36,136.8 Lowest | 80 ₹36,136.8 Lowest | 150 ₹67,756.5 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 242.17 | Cum | 40 ₹9,686.8 | 35 ₹8,475.95 Lowest | 50 ₹12,108.5 |
| 3.00 | Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. | 209.54 | Cum | 50 ₹10,477 | 35 ₹7,333.9 Lowest | 50 ₹10,477 |
| 4.00 | M&L for sand cushioning to underground cable with clean dry river sand 8cm before laying of cable and 15 cm after laying cable complete all as specified and directed by Engr-in-Charge.
Note:- Punned thickness only shall be measured & Paid. | 135.51 | Cum | 350 ₹47,428.5 Lowest | 450 ₹60,979.5 | 600 ₹81,306 |
| 5.00 | Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed. | 14.55 | Per 1000 Nos | 3,500 ₹50,925 Lowest | 4,000 ₹58,200 | 6,000 ₹87,300 |
| 6.00Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned sizes complete all as specified and directed by Engineer-in-Charge. | ||||||
| 6.01 | 10 Sqmm 2 Core. | 400 | RM | 110 ₹44,000 | 85 ₹34,000 Lowest | 125 ₹50,000 |
| 6.02 | 16 Sqmm 4 Core. | 320 | RM | 140 ₹44,800 Lowest | 172 ₹55,040 | 180 ₹57,600 |
| 6.03 | 25 Sqmm 3. 5 Core. | 340 | RM | 170 ₹57,800 Lowest | 210 ₹71,400 | 220 ₹74,800 |
| 6.04 | 35 Sqmm 3.5 Core. | 280 | RM | 210 ₹58,800 Lowest | 250 ₹70,000 | 250 ₹70,000 |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
29 Sept 2025, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR/MAINT OF UNSERVICEABLE ACBS AND CONNECTED ITEM ALONG WITH COMPREHENSIVE MAINT OF MES INSTALLATION OF PUMP HOUSE/ POWER HOUSE/SUB STATION AT AYODHYA CANTT UNDER AGE (I) AYODHYA.
2025_MES_727664_1
82010/AYD/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Class C and Category b(i)
6 documents required · 6 mandatory
₹1,000
AGE (I) Ayodhya
₹1.1 L
Yes
10 Jan 2026
25 Aug 2025
6 Oct 2025
25 Aug 2025
29 Sept 2025
15 Sept 2025
Amount
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to underground cable with clean dry river sand 8cm before laying of cable and 15 cm after laying cable complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid.
Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned sizes complete all as specified and directed by Engineer-in-Charge.
10 Sqmm 2 Core.
16 Sqmm 4 Core.
25 Sqmm 3. 5 Core.
35 Sqmm 3.5 Core.
50 Sqmm 3. 5 Core.
70 Sqmm 3. 5 Core
95 Sqmm 3. 5 Core.
120 Sqmm 3. 5 Core.
Disconnecting electrically incomming and outgoing LT UG cable of LT panel/AMF Panel of any size and replace burn/unsv suitable size of aluminium bus bar, Welding work for hinches and doors, fixing the locking arrangement including scraping outdoor/indoor side of LT Panel / AMF Panel and one coat of redoxide, two coat of synthetic enamelled seimens gray spray of outdoor/Indoor side and reconnecting LT UG cable with fixing cable gland of all suitable size cable and aluminium lugs by using crimping tool, nut, bolt washer etc and all necesary work required for smooth functioning of LT panel / AMF Panel all specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN 63 A, 4 poles current carrying capacity with connection testing and commissioning all as specified and directed.
Supply & fix in replacement of MCCB, 4 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed
Supply & fix in replacement of MCCB, 4 pole, 125 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed.
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed .
Supply & fix in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed
Supply & fix in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed
Supply & fix in replacement of MCCB, 4 pole, 400 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed
Supply & fix in replacement of ACB, 4 pole, 630 Amp, 415V 50Hz with Microprocessor based SR18G, MDO, C - power Draw -out ACB, including under voltage, rating breaking capacity 50 kA,with connection and testing complete all as specified and as directed
Supply & fix in replacement of ACB, 4 pole, 1000 Amp, 415V 50Hz with Microprocessor based AHA-10S-CS, MDO, C - power Draw -out ACB, including under voltage, rating breaking capacity 50 kA,with connection and testing complete all as specified and as directed
Supply & fix in replacement of On load Change over switch 400 Amp, 415V 50Hz with Sheet steel enclosure and operating handle confirming to IEC : 60947-3 including connection and testing complete all as specified and as directed
Supply & fix in replacement of On load Change over switch 125 Amp, 415V 50Hz with Sheet steel enclosure and operating handle confirming to IEC : 60947-3 including connection and testing complete all as specified and as directed
Supply & fix in replacement of On load Change over switch 63 Amp, 415V 50Hz with Sheet steel enclosure and operating handle confirming to IEC : 60947-3 including connection and testing complete all as specified and as directed
Servicing/Repair the ACB of various Capacity of outdoor/indoor type, tripping circuit and resetting trip values and the nuemerical relays and checking tripping machnism fully by engaging well experianced technicians as per manufacturer recommendation complete all as specified and as directed
Shifting of LT Panel after Disconnecting all the electric connections from and earthing terminals from the LT Panel including fixing to another bay with new foundation and necessary earthwork complete all as specified and as directed. Note:- Cost of PCC 1:2:4 B-1 as in foundation and earthwork are deemed to be included in the qouted rate.
M&L for Indicator lamp LED type (R,Y,B) complete with bakelite fuse complete all as specified and directed
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, powder coated with 7 tank process,TPN copper busbars of rating 250 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 Nos earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 250 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT of suitable ratio (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, ,25 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt feeder panel shall be got approved from GE. 4. panel shall confirm to IEC - 61439 updated to date.
Labour for cutting/ trimming of tree branches up to 80mm thickness along the alignment of LT /HT over head electric line which are going/ touching or falling or ACSR conductor/ poles or near by sub stns etc at any height from GL and making at least clearance 1.5m form conductor and removing to a distance up to 100 mtr where directed by Engineer-In-Charge. Note:- (i) Trimming of the branches on one sides of the conductor. (ii) Actual length of cutting will be measured. (iii) The distance as mentioned above will be maintained during contract current period & same location subject to at least 6 months period between two trimming/laping. (i) Measurement will be taken including all conductor as one only.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron strip of size 25 x 4mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engr-in-Charge.
S&F Straight through cable joint kit with jointing materials and accessories for LT UG cable of following sizes complete all as specified and directed .
16 Sqmm 4 Core
25 to 50 Sqmm 3.5 Core
70 to 120 Sqmm 3.5 Core
150 to 185 Sqmm 3.5 Core
240 to 300 Sqmm 3.5 Core
Supply and fixing in repair aluminium sector lugs short barrel of following sizes:
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
Outdoor/indoor 16 to 25 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 70 to 120 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 150 to 185 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Hiring of cable fault detector, to detect exact position of fault for XLPE /PVC LT/HT cable, 1100/11000 Volts grade heavy duty aluminium conductor of any size including to and fro transporting charges etc. complete all as specified and directed .
Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables up to 2 mtr deep complete all as specified and directed . Note : GI pipe shall be measured and paid separately.
Supply & laying GI Pipe tubing, 50mm dia. galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified.
Supply & laying GI Pipe tubing, 80mm dia. galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified.
M & L for Structural steel work using rolled mild steel section of Fe-290 (Gde E-165) like Angles, flat, square, round bars as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc all as directed.
M/L for Cement concrete for filling in foundations or making good of Road, PCC Floor, supports etc. Type B1, 1:2:4, using 20 mm graded crushed stone aggregate including necessary form work and fair finishing of exposed surface of concrete / facia finish with cement mortar complete all as directed.
M&L for chain link fencing galvanised including line wires 4 mm dia, mesh size 150x100mm weight not less than 2.3 Kg/sqm fixed with standards rails, straining bolts etc. Including provision of binding wire and fixing complete all as specified and directed.
Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and directed .
Preparation of old painted surface of RCC poles up to the height of 1.5 mtr height and painted with one coat of synthetic enamel paint in strips alternative with black and white colour paint and marking pole number including painting MS channel 'D' clamps bracket, GI pipes etc with one coat of aluminium paint complete all as directed.
S&F pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut, 100mm height, 65 mm dia for 1100 bolts gradecomplete all as specified and directed .
S&F shackle type, porcelain, vitreous, white brown or green insulator of size 75mm high and 90mm dia including galvanised mild steel straps of section 31mm x 3mm, 12mm dia insulator bolts, nuts, washer etc for working pressure 1100 voltscomplete all as specified and directed .
S&F small size loop type insulator, vitreous porcelain, white, borwn or green with overall dimensions 65 x 90mm clearance of hole 16mm complete all as specified and directed
M&L for aluminium conductor, steel reinforced (ACSR) of any size as approved on LT poles including straining, binding to insulators with aluminium binding wire with connectors, etc providing PVC sleeves for jumpers as in OH conductors complete all as specified and directed.
Re-Straining tightening of existing ACSR conductor of any size on LT/HT poles including necessary aluminium binding wire, connectors, PVC sleeves for jumpers etc complete all as specified and directed .
Supply and fix Powder coated Pin Type Panel lock in round shape (Male & Female socket) diameter appx 22 mm for female socket complete all as specified and as directed
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/PCC area of size 20 sqmm etc.complete all as specified & as directed.
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc.complete all as specified & as directed.
Supply and fixing of suitable size of nut, bolts/ washers of brass/GI for replacing defective nut, bolts etccomplete all as specified and as directed
Supply and lay DWC HDPE pipe 50 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Supply and lay DWC HDPE pipe 80 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
M&L for dot matrix rectangle LED Screen in size 2 feet X 1 feet with display technology dot matrix, laungage supported english/hindi,Lighting type -LED, , physical pixel-6mm,brightness-6500nits,body material-Die cast,life span -100000 hours,refresh rate-2000hz for display of installation details with max 50 letters display on board complete all as specified and directed. Note-1 Electric Connection of display panel board shall be deemed to be included in quoted unit rate. 2-fixing of panel board with proper arrangement shall be deemed to be included in quoted unit rate.
Cleaning of surrounding area of E&M installation around the bldg,transformer,GOD LT panel,pump house by grass cutting manually or mechanically (Brush Cutter) as per requirement basis and trimming as directed by Engr-in-Charge,including taking out all shrubs,saplings with bushes and any type of vegetation and removing from site complete all as specified and directed.
M&L for coarse aggregate not less than 40 mm graded nominal size without any vegetation or chemical incl levelling spreading all around complete all as specified and directed.
S&F LED board of size 15'X3'X4'' (L x W x H) made out of 24 guage GI sheet and front with acrylic sheet total enclosed with computerised letter writings of size not less than 100 mm as decided by Engr-in-charge and inside with 4x20W LED tube light complete with time control switch , MCB and battery back up with timer and synchronised motor board should be fix on 40mm dia medium grade GI pipe of 5' height board from Bldg roof ( 3' from the bottom of the board ,3' depth of the board and 1' embedded in PCC above Bldg roof),fixed in PCC 1:2:4 type B-1 using 20mm graded agg of size 450*450*600mm with complete wiring of 2 sqmm 3 core copper sheathed cable 10 meter long including service connection from the Bldg main DB by means of 25mm dia light grade pipe to the board. The cable inside the board shall run in PVC reinforced flexible conduit including PCC work for fixing of board on Bldg roof. The details to be written with computerised writing including taking down of old unsv board complete all as specified and directed.
Supply and fixing glow sign board (box type) of size 1500 mm x 1200 mm x 200 mm cladding PGI sheet 18 gauge fixed on aluminium angle of size 25 mm x 25 mm x 3.00 mm on top/bottom both side and transfrant acrylic sheet 3.00 mm in front on which lay out of station HT electrical equipment and cables to be marked with different colours as directed complete with 4x20W LED tube light with wiring of 1.00 sqmm 3 core copper sheathed cable 10 meter long including service connection from the Bldg main DB by means of 25mm dia light grade pipe to the board complete all as specified and directed.
M&L for making of Poster related to Water conservation/Electricity Saving with writing slogan on external surfaces of pump house/Sub station boundary wall in suitable colour after preparation of old complete external boundry wall surface by taking down of old/ broken tiles,scraping, washing, rubbing down and stopping of distempered and painted and applying two coat of cement based paint on complete external surface of pump house boundary wall complete all as specified and directed by Engr-in-charge. [Note:- (i) Before applying cement paint, the complete external boundry wall surface shall be thoroughly wetted to control surface suction. (ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used] complete all as specified and directed .
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed .
M&L prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed .
M&L for Rolled mild steel in Joist ,channel,angle, or tee sections, fixed independently, without connecting plates, etc. for repair to staircase,hand rails,back rest of over head reservoir, gate, shed of generator set & panel, etc or as specified and directed . [Note:- All T&P including welding machine and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
S&F in replacement of Garden/ Gate light Decorative made up of high grade unbreakable polycarbonate material powder coated including one LED lamp 14W/20W B22 base and fixed with suitable dia & height light grade GI Pipe complete all as specified and directed . Make- Havells Cat pat No :- CORALMINIPT15WLED757PSYMTOPC or equivalent to Bajaj/ Philips/ CG.
S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed .
Supply and errect 6 mtr long Hot dip galvanised octagonal pole with 130mm bottom A/F and 70mm top A/F made up of 3mm thick HT steel plate having base plate of 220x220x12mm thick alongwith, 4 Nos M20 x 700 mm GI 'J' type foundation with door opening 0.90x 350 mm, with bolts,nuts complete all as specified and directed.
M&L for RCC foundation of grade M20 (1 cement : 1.5 sand : 3 stone aggregate) of size 550mm x 550mm x 1400mm out of which 1200mm shall be below F.G.L.(Finished Ground Level) using 4 Nos. 12mm dia steel reinforcement of grade Fe-415 with 50 mm clear cover to reinforcement and rings using 8mm dia steel reinforcement @ 190mm C/C using shuttering, along with supply & installation of 2 Nos. of 63mm dia PVC pipe for cable entry and cable exit. 4 Nos. 'J' type foundation bolts shall be anchored in the foundation (PCD of 205 mm) in such a way that 125mm length of bolt is projected above foundation. It includes water curing as required and soil excavation & backfilling. It also includes supply of all material and labour including erection of foundation at Site.
S&F in replacement of All-in-One Solar Street Light 20 Watt, 12.8 Volt, 24 Amp Li-FePo4 Battery with Mppt Charge Controller Mono Solar Panel, including connection and testing complete all as specified and directed
Repair and maintenance of submersible pump set any make & model of capacity upto 45 HP including required repairing if any like motor rewinding, replacement of minor spares like CI/ MS bowl (As per existing size), stainless steel shaft with key, stainless steel sleeve, sand guard ,impeller lock with key, neck ring (as per existing size and type), stainless Steel thrust bearing, carbon plate, gun Metal bush, rubber bush, upper housing, lower housing, housing & sleeve repairing on Lathe, rubber gasket, nut bolt,painting and testing after servicing complete all as specified and directed. [Note: (i) All type of T&P like chain pully block etc and lifting and lowering of motor pump along with column pipe,submersible cable from deep borewell out required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.(ii) New submersible cable will be measured and paid separately ]
M&L for applying two coats of cement based paint on all external surface of overhead reservoir of capacity 100000 gallons including columns and beams of staging up to 21 metre high after scraping/ preparing of Old surfaces and two coats of synthetic enamel paint on Inlet, outlet, overflow and washout CI/ GI/ DI pipes and complete staircase as per existing colour from ground level up to top of the reservoir complete all as specified and directed . [Note: - (i) Before applying cement paint, the surface shall be thoroughly wetted to control surface suction(ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used]
M&L for applying two coats of cement based paint on all external surface of overhead reservoir of capacity 50000 gallons including columns and beams of staging up to 21 metre high after scraping/ preparing of Old surfaces and two coats of synthetic enamel paint on Inlet, outlet, overflow and washout CI/ GI/ DI pipes and complete staircase as per existing colour from ground level up to top of the reservoir complete all as specified and directed [Note: - (i) Before applying cement paint, the surface shall be thoroughly wetted to control surface suction(ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used]
S&F portable fire extinguisher, dry powder type (gas catriage) mild steel with cylinder internally fully charged with dry chemical powder (ABC type fire class) of 4 Kg complete with standard discharge valve with tube, discharge range 6 meter including CI bracket for wall mounting etc all as specified and direcetd.
S&F portable fire extinguisher, dry powder type (gas catriage) mild steel with cylinder internally fully charged with dry chemical powder (ABC type fire class) of 2 Kg complete with standard discharge valve with tube, discharge range 6 meter including CI bracket for wall mounting etc all as specified and direcetd.
Demolition of cement concrete carefully of any description not otherwise specially provided for under RCC Overhead reservoirs and pipe supports etc before taking out of old pipes including removal demolishrd material distance exc.250m and depositing where directed upto total distance of 1.5Km complete all as specified and directed .
M&L for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation filling & mass concrete fair finish over surfaces as under RCC Overhead resevoirs with required slope for smooth flow of water and as in supports or as per site requirement complete all as specified and directed.
S&F first AID kit box -wall mount,multi compartment of size height 32 cm,width 28 cm , depth 8 cm made from high grade GI metal with 6 way processed powder coating for anti rust proof with front glass fitted 3 shelf, security lock on door to accommodate all necessary items mentioned below, complete all as specified and directed. (i) 1 Pc normal saline 100 Ml (ii) 2 Pcs snake bite Lancet (iii) 1 Pc suction pump set (iv) 5 Pcs antiseptic Wipes (v) 1 Pc Sterlile wound dressing (vi) 2 Pcs scalpel blade (vii) 1 Pcs syringe 10 Ml (viii) 2 pcs tourniquet (ix) 1 Pc razor (x) 1 Pc scissor (xi) 1 Pc adhesive Bandage (xii) 1 Pc Heavy Crepe Bandage width 7.5x3 cm etc
S&F, installation testing and commissioning of outdoor type, double door cubical panel board suitable for 3 phase, 4 wire, 415 volt, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and vermin proof and general constructions confirming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control grear. The panel should have suitable size of Copper bus bar three phase 4 wire system having current carrying capacity 400 amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and directed by Engr-in-Charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate) complete all as specified and directed. (i) MCCB 4 pole, 35 KA with adjusable thermal setting, 415V, 160 Amp-01 No. (ii) MCCB 4 pole, 35 KA with adjustable thermal setting, 415V, 100 Amp-01 No. (iii) Star Delta starter comprising of 3 pole contactors suitable for submersible pump motor capacity with thermal over load relay complete - 01 No. (iv) Motor protection relay for single phase, over load, over voltage. (v) Digital volt meter 0-500 volts. (vi) Ammeter 0-500 amps with suitable size of CTs (vii) All connection to be done through suitable size PVC insulated copper cable.
(viii) LED RYB indicator- 01 Set. (ix) MCB TP 32 Amps 10 KA - 01 Nos. (x) MCB SPN 32 Amps 10 KA - 02 Nos. (xi) Copper bus bar 300 Amp 4 strip (xi) Single phase preventor - 01 No. (xii) On load chnage over switch 100 A Open execution type -02 Nos
M&L for steel works in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade ST-240 complete all as specified and directed..
MTR GROUP & COMPANY (BID ID -3438636)
Unnati Engineers (BID ID -3438829)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .