| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹75.3 LAccepted-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE KALIMATA MANDIR ROAD PATHANKOT PUNJAB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹78.5 L+₹2.5 L (3.30%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹84.8 L+₹8.8 L (11.6%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹94.1 L+₹18.1 L (23.8%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹95.5 L+₹19.6 L (25.7%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
7 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
DEVELOPMENT OF E/M INFRASTRUCTURE AND ASSOCIATED WORK SERVICES AT AF STATION PATHANKOT
2022_MES_504780_1
CWEAFJ-33/2021-22
Open Tender
Civil Works
Item Rate
180 days
Pathankot
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (AF) Pathankot
₹1.8 L
Yes
24 Mar 2022
31 Jan 2022
9 Mar 2022
31 Jan 2022
7 Mar 2022
21 Feb 2022
60 days
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. Notes for Serial Item No '01' & '02' : The Contractor shall take due precaution while excavation for not damaging existing Water Supply Lines, Electrical and Communication Cables etc. any damage occured to the same during excavation shall be made good by contractor without any extra cost to the department
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting of existing road / hard standing for laying of GI protection pipe for cables, depth of trench not exceeding 0.75mtr, width of trench not exceeding 1.0mtr and making good by returning filling in (by well ramming and watering of soil in layers not exceeding 25cms), provision of 150mm thick sub base, 150mm thick WBM and thereafter 150mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate) including removal of surplus spoil to a distance not exceeding 50mtrs complete all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick cast iron base plate, finial taper plug, MS bolts, nuts, screws including painting 06 Nos bands / strips of 30cms each starting from the bottom of the pole (i.e. above the PCC coping) with white and red post office box colour in alternate strips and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer and numbering of poles with black synthetic enamel paint in 2.5 cm height including black bitumenous paint two coats on steel surface embedded in concrete foundation all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer all as specified and as directed.
Supply and fix Lightning Arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps complete all as specified and directed.
Switch Air break, gang operated (GOD) with 12 Nos insulators, Outdoor type, mechanically operated, suitable for horizontal or vertical mounting rotating type, provided with locking arrangements consisting of MS channel, operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete, all as specified and directed.
Danger notice plate, for HT, of size 25cm x 20cm x 1.5mm thick mild steel sheet, vitreous enamelled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 120 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 95 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 185 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 120 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 70 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 35 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 2 Core x 16 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Indoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for straight through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, Class HVP, type 1 with peak, size 300mm x 180mm x 40mm, complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, Class HVP, type 1 with peak, size 250mm x 150mm x 40mm, complete all as specified and as directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Cable Route Indicators 4" x 4" round / square welded or bolted with angle iron stand 40 x 40 x 6mm MS angle 60cm long, marked HT / LT cables including embedding in PCC 1:2:4 size 30cm x 30cm x 30cm over cable, to be fixed on each turning, at joint across road crossing and distance as per site requirement.
Supply, installation, testing and commissioning of step down Transformer 11 KV / 433 Volts (at no load) 3 Phase 50 Hz, 250 KVA, copper wound, outdoor type, with off load tap changing arrangement of HT side to vary secondary voltage upto ± 7.5 % in step of ± 2.5% including suitable cable entry boxes both on HT and LT to receive 95 Sqmm 3 core XLPE cable on HT side complete in all respect with standard accessories and fitment confirming to IS-1180 Part-I of 2014/ and BEE certified, Dyn -11 connection complete all as specified and directed. The salient features of Transformer shall be as follows :- (a) Transformer shall be oil immerse, naturally self cooled double wound copper, winding core type, MS radiator cooled tank complete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1980 with test certificates with on cooling system.
(b) Rating and diagram plates (c) Earthing terminals = 02 Nos (d) Lifting lugs. (e) Thermometer pocket (f) Air release hole with plug (g) Winding /Oil temperature indicator (h) Conservation with oil level indicator (j) Castors with locking provision (k) Silica Gel breather complete
Platform for installation of Transformer of size 3000mm x 2500mm x 1200mm with brick construction in cement mortar 1:4, PCC 1:3:6 type C-2 in foundation, PCC 1:2:4 type B-1 in floor, brick masonry step on one side, XPM Jalli and fixed on angle iron 50 x 50 x 6mm post and gate openable type with locking arrangements, earth work in any type of soil including plastering to brick masonry work in cement mortar 1:4 and painting to steel surface with two coats of synthetic enamelled paint over a coat of primer and two coats of colour washing over a coat of white wash on plastered surface including MS stand with locking arrangement for mounting transformer complete all as specified and as directed.
Supply, installation, testing and commissioning of LT Panel cubical type 440 Volts 3 phase 4 wire outdoor type front operated any CPRI approved with adequate Air Ventilation at both sides & back & fabricated out 3.15 thick CRCA sheet with double door shutter with locking arrangement with water proof dust & vermin proof, pre fabricated hinges for rear & front door with locking arrangement complete with inter connection with copper wire / strip, tapping bonding to earth & all frames inner & outer door shall be coated by polyester powder paint of shade RAL 7032 Siemens grey stand of distribution board shall be coated by primer & black Bituminous paint, cable trays, cable lugs, cable Glands of any size with suitable to accommodate and including following mentioned fittings & fixture with suitable nut, bolt, washer etc.
CPRI approved including provision for taking out cable duly marked riveted letter at appropriate size for each feeder cable & reconnection with duly insulated cable terminals with heat shrinkable sleeve with 1.1 KV grade Danger notice board etc. (i) Bus bar chamber consisting four Nos Aluminium busbar of capacity Suitable size duly insulated with heat shrinkable sleeve 1.1 ka grade with RYBN mounted on heavy duly Epoxy insulator in separate compartment. (ii) Digital type volt meter 01 No. and Digital type Amp meter with suitable cap of CT - 01 No. (iii) LED indicating lamp (RYB) for incoming and indicating lamp (RYB) for each out going (iv) Panel board internal wiring with suitable PVC insulated multistranded copper conductor cable flexible cable.
Incoming (i) MCCB, Four Pole, 415 Volt, 200 Amps capacity with 36 KA with adjustable thermal magnetic trip unit/release with Ics= 100% Icu quantity 01 No. Outgoing (i) MCCB, Four Pole, 415 Volt, 100 Amps capacity with 16 KA with adjustable thermal magnetic trip unit/release Ics= 100% Icu= 4 Nos. (ii) MCB SPN 32 A - 02 Nos
Supply, installation, testing and commissioning in replacement of LT Panel, Cubical type, 440 Volts 3 phase 4 wire outdoor type front operated any CPRI approved with adequate Air Ventilation at both sides & back & fabricated out 3.15 thick CRCA sheet with double door shutter with locking arrangement with water proof dust & vermin proof, pre fabricated hinges for rear & front door with locking arrangement complete with inter connection with copper wire / strip, tapping bonding to earth & all frames inner & outer door shall be coated by polyester powder paint of shade RAL 7032 Siemens grey stand of distribution board shall be coated by primer & black Bituminous paint, cable trays, cable lugs, cable Glands of any size with suitable to accommodate and including following mentioned fittings & fixture with suitable nut, bolt, washer etc.
CPRI approved including provision for taking out cable duly marked riveted letter at appropriate size for each feeder cable & reconnection with duly insulated cable terminals with heat shrinkable sleeve with 1.1 KV grade Danger notice board etc. (i) Bus bar chamber consisting four Nos Aluminium busbar of capacity Suitable size duly insulated with heat shrinkable sleeve 1.1 ka grade with RYBN mounted on heavy duly Epoxy insulator in separate compartment. (ii) Digital type volt meter 01 No. and Digital type Amp meter with suitable cap of CT - 01 No. (iii) LED indicating lamp (RYB) for incoming and indicating lamp (RYB) for each out going (iv) Panel board internal wiring with suitable PVC insulated multistranded copper conductor cable flexible cable
Incoming (i) MCCB, Four Pole, 415 Volt, 250 Amps capacity with 36 KA with adjustable thermal magnetic trip unit/release with Ics= 100% Icu quantity 01 No. Outgoing (i) MCCB, Four Pole, 415 Volt, 200 Amps capacity with 25 KA with adjustable thermal magnetic trip unit/release Ics= 100% Icu = 2 Nos. (ii) MCCB, Four Pole, 415 Volt, 125 Amps capacity with 25 KA with adjustable thermal magnetic trip unit/release Ics= 100% Icu= 3 Nos. (iii) MCB SPN 32 Amps - 02 Nos (iv) Front operated Four Pole 160 Amps On load Change Over Switch - 01 No
Supply, installation, connecting electrically & commissioning LT Feeder Box, outdoor type of size 0.90m x 0.60m x 0.40m size, factory fabricated, made out of MS sheet of thickness 3.15mm front and back door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40 x 40 x 6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30 x 0.30 x 0.50 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 600 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators and one No. MCCB 400 AMP,50 KA, 4 Pole 415 V make Legrand, all as specified and directed.
including making/breaking existing wall for mounting/fresh air etc. and making good the disturbed surfaces matching with existing including all items required for proper functioning of Dehumidifier as per site requirement complete all as specified and directed. Make : Model FFB-3000 of Bry-Air or equivalent as approved by GE
Supply installation testing and commissioning Stainless Steel body Ultrasonic Humidifier Machine of capacity 80 Kg/hour for humidity control including molecule sprayed 0.5 to 5 micron compact, Voltage 220 Volts AC, cycle 50 HZ, Power input 4800 Watts, Air Volume 2900 Cum/hour complete including mounting provisions as required, including necessary ducting work and other civil/masonry work required, including making/breaking existing duct for mounting humidifying air etc. and making good the disturbed surfaces matching with existing including all items required for proper functioning of humidifier as per site requirement complete all as specified and directed. Make : Model NTC - G080Z or equivalent as approved by GE
Wiring for circuit / Submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in PVC conduit as required 4 x 25 Sqmm + 2 x 25 Sqmm earth wire complete all as specified and directed.
Wiring for circuit / Submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in PVC conduit as required 2 x 6 Sqmm + 1 x 6 Sqmm earth wire complete all as specified and directed.
Three Pole MCCB 100 Amps, 50 Hz, 415Volts with rupturing capacity 25 KA (adjustable thermal and magnetic release) including suitable outdoor type mounting enclosure complete all as specified and as directed.
Triple Pole and Earth Enclosure with a Three Pin and Earth Plug with Socket complete with one Triple Pole MCB 63 Amps complete all as specified and directed.
Two Pole and Earth Enclosure with a Three Pin and Earth Plug with Socket complete with one Double Pole MCB 20 Amps complete all as specified and directed.
Supply, assembly and erection in replacement of GI sheet with TDF flange rectangular / square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corners, Cleats, Carriage Bolts, including 3 mm thick Gasket and appropriate sealant on longitudinal joints etc. complete of size 24 Gauge complete all as specified and as directed.
Supply, assembly and erection in replacement of GI sheet with TDF flange rectangular / square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corners, Cleats, Carriage Bolts, including 3 mm thick Gasket and appropriate sealant on longitudinal joints etc. complete of size 22 Gauge complete all as specified and as directed.
Supply, assembly and erection in replacement of GI sheet with TDF flange rectangular / square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corners, Cleats, Carriage Bolts, including 3 mm thick Gasket and appropriate sealant on longitudinal joints etc. complete of size 20 Gauge complete all as specified and as directed.
Supply, fabrication and installation / fixing in replacement of galvanized iron sheet (22 guage) Volume Control Damper with in ducts at AHU end and fresh air damper provided with suitable links, levers and quadrants for manual control of air flow and for proper balancing of the air distribution system, complete all as specified and directed.
Supply, installation / fixing, motorised Combined Fire Damper of galvanized iron sheet (22 guage) with Actuators and Control Panel including wiring / inter connecting wiring as required and as per specification, complete all as specified and directed.
Supply, installation / fixing, powder coated aluminium of suitable section Diffuser with Volume Control Damper for supply Air Duct (SAD with VCD) including providing proper water tight insulation at the entrance point of building to make it leak proof and filling openings at entry points with suitable material to keep it leak proof, complete all as specified and directed.
Supply, installation / fixing, powder coated aluminium of suitable section Diffuser without Volume Control Damper for supply Air Duct (RAD without VCD) including providing proper water tight insulation at the entrance point of building to make it leak proof and filling openings at entry points with suitable material to keep it leak proof, complete all as specified and directed.
Duct Insulation with Fibre Glass Wool Sheet 50mm thick density not less than 24 Kg/Cum and covered with chicken wire mesh and 10mm thick cement and plaster decoratively including providing a suitable weather proof paint coating camouflage on the plaster as approved by Engr-in-Charge complete all as specified and directed.
Taking down carefully existing CGI / PGI sheet including removing supporting structure sheets and other connected accessories and removing to store for keeping in safe custody for reuse at site and refixing after repair of ducts to same location having length approximate 25 metre and width approximate 1.5 mtr mounted on ceiling having supports on wall complete all as specified and directed by Engr-in-Charge.
Supply, installation / fixing Duct Insulation with 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/Cum and covered with approved best quality aluminium foil with appliances and rubber based adhesive pidilite SR 998 or equivalent as approved, as in AC's / Attic space inside building complete all as specified and directed.
Rotational moulded polyethylene Water Storage Tanks of capacity 1000 litres, (cylindrical vertical with threaded top), three layered, hoisted and fixed in position including supply and fixing necessary GI fittings, inlet / outlet washout, overflow pieces long nipples, check nuts & washer, brass valve 20mm high pressure with polythene float and fly nut etc. complete, all as specified and directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 150mm, complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 40mm, complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20mm, complete all as specified and as directed.
Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe 40mm and fixed, complete all as specified and as directed.
Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe 20mm and fixed, complete all as specified and as directed.
Bib Taps, cast copper alloy with crutch or butterfly, handle, screwed for iron pipes of 15mm bore complete all as specified and directed.
Cutting the existing distribution mains and connecting to 20/40mm GI pipe in position after cutting of existing pipe line and dismantling the existing gate valve and fixing of GI Tee of suitable size including threading of the existing pipe, fixing of unions and re-fixing the existing pipe without disturbing existing line including necessary earth work complete all as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI Strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on Electric Plate No. 03 of SSR-2009 Part-I, complete all as directed.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI Strip of size 25 x 4mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on Electric Plate No. 03 of SSR-2009 Part-I, complete all as directed.
M/S SINGH AND ASSOCIATES
SATISH AND CO
Vijay Kumar Contractor and Engineers
M/S SHRI RAM BUILDERS
Bidder Name
Vijay Kumar Contractor and Engineers
SATISH AND CO
M/S SHRI RAM BUILDERS
M/S SINGH AND ASSOCIATES
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .