Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.5 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L1 | Admitted-Finance | ||
| 2 | L2₹14.6 L+₹5,025.56 (0.35%)Admitted-Finance 1853 2ND FLOOR BHAGIRATH PALACE SURYA BAZAR CHANDI CHOWK NORTH DELHI DELHI 110006 | NORTH | DELHI | 110006 | L2 | Admitted-Finance | ||
| 3 | L3₹15.4 L+₹81,381.73 (5.60%)Admitted-Finance | L3 | Admitted-Finance |
Tender Value
₹16.2 L
EMD Value
₹32,423
Closing Date
2 May 2026, 11:00 amClosed
Executive Engineer (E)
Executive Engineer (E),PWD NES/M-251, LM Bund Road, Ramesh Park, Delhi
Providing and installation of Air Conditioners at DSSSB, Karkardooma, under jurisdiction of PWD Sub Division -3/M2533, Shahdara, Delhi.
2026_PWD_290390_1
10/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
Percentage
30 days
under sub div-2533
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹32,423
Yes
4 May 2026
25 Apr 2026
2 May 2026
25 Apr 2026
2 May 2026
25 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | |||||
| 1.1 | 25 mm | - | Mtr | - | - |
| 2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 2.1 | 3 x 6 sq. mm | - | Mtr | - | - |
| 3Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | |||||
| 4Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type | |||||
| 4.1 | 1.5 TR with Inverter 5 Star BEE rating | - | Each | - | - |
| 5Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall splittype Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only | |||||
| 5.1 | 1.5 TR with 5 Star BEE Rating | - | Each | - | - |
| 5.2 | 2.0 TR with 5 Star BEE Rating | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.15 MB
BOQ_385426.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .