Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC being L1 | |
| 2 | L2₹43.6 L+₹12.8 L (41.5%)Accepted-AOC | L2 | Accepted-AOC Not being L1 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
21 Jan 2022, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS OLD UNSV WIRING AND CONNECTED WORKS AT CERTAIN OTM/ MARRIED ACCN AND REPAIR/ REPLACEMENT TO PIPE LINE AND PUMPS MOTOR AND DG SETS AT KHANPUR DUNDAHERA AND MANESAR ARMY CAMP UNDER AGE E/M SOUTH OF GE SOUTH DE
2021_MES_488212_2
GE/DS-66/2021-22
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹99,800
Yes
21 Feb 2022
31 Dec 2021
24 Jan 2022
31 Dec 2021
21 Jan 2022
7 Jan 2022
1 Jan 2022 - 5 Jan 2022
Amount
Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints are Khanpur Camp, Dundahera Army Camp & Manesar Army Camp. Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830Hrs to 1700Hrs including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7.The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here-in-after.
S&F in repairs of switch piano flush type 6 Amps SP one way Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of switch piano flush type 6 Amps SP 2-way Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs bell push, flush type 6 Amps Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of switch piano type 16 Amps SP one way Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of lamp holder bakelite insulated body with back plate suitable for batten fitting Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of bell Ding dong type 230 volts single phase Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ceiling rose surface Bakelite 65x25 mm two to three terminals Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of fan condenser 2.5 Mfd Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of fan condenser 3.15 Mfd Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of LED Glass Bulb 12 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base Complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No. LHFHCHE1TL1W020 of Havells or its equivlent as specified make.
S&F in repairs Rugby Bulk head 8 watt in die cast aluminium housing & frosted glass Complete all as specified and directed by Engineer-in-Charge. Make:- Cat LHKL01160099 of Havells or its equivlent as specified make
S&F in repairs of LED Batten T-5 fitting 20 watt LED White, indoor decorative aluminum extruded T5 LED battern -integrated type environmental friendly Complete all as specified and directed by Engineer-in-Charge. Make:- Cat Part No LHEXARP7IN1W020 of Havells or its equivalent as specified make
S&F in repairs of LED Integrated Batten T5 10 watt - 2FT White, indoor decorative polycarbonate extruded T5 LED battern-integrated type environmental friendly Complete all as specified and directed by Engineer-in-Charge. Make:- Cat Part No LHEXACP7IN1W010 of Havells or its equivalent as specified make
S&F in repairs Surface mounting round shaped LED downlighter with Slim surface mounted 6 watt LED panel with premium diffuser to ensure glare free & even light distribution Complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No. LHEAAHP7IL1W006 of Havells or its equivalent as specified make
S&F in repairs of LED Building security light fitting 45W energy saving and environmental friendly LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection Make:- Cat Part No SL45WLED757PASYTOPC of Havells or its equivalent as specified make
S&F in repairs of Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm for any type of wiring as per site requirement Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement Complete all as specified and directed by Engineer-in-Charge.
S&F PVC casing caping of size 25mm with suitable size of nails for fixing PVC casing caping, in repairs of batten/surface wiring Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for submain wiring PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm in 2 runs and 2.5 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in repairs for submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Taking down of old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing Complete all as specified and directed by Engineer-in-charge. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for Rewinding of ceiling fan 1200/ 1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required Complete all as specified and directed by Engineer-in-charge. Note : Clamp, shaft, rod, bearing and painting of fan with good quality of synthetic enameled paint and marking the MES Number as per existing including lathe machine work if necessary to making a uppper/lower sheet of fan will be measured under this item only.
All same as per item No. 28 above but exhaust fan/wall fan upto 450 mm sweep
S&F in repairs Gun metal bush for fans Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Ball bearing of suitable size & model for ceiling/Exhaust fan Complete all as specified and directed by Engineer-in-Charge. Make:- NBC/ SKF or equivalent.
M&L for replacement of exhaust fan iron blades for size 300/450 mm sweep as per sample Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ceiling fan holder hook with rubber real suitable for size 1200/1400 mm ceiling fan as per sample Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC canopy for ceiling fan of size 1200/1400 mm as per sample Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs plug top 20 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirement of existing type Complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium lugs of size 25 Sqmm to 95 sqmm for connecting PVC cable complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium lugs of size 95 Sqmm to 300 sqmm for connecting PVC cable complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB DB SPN 4 Way double door type,(IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB DB SPN 8 Way double door type,(IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCCB 3 Pole 415V, Adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCCB 3 pole, 415V, Adjustable type,125 amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Recessed mounting 36 Watt 2'x2' flat LED panel fitting luminaire to enhance the delight of occupants with comfortable experience through its classic design and glare & Flicker free illumination. White powder coated CRCA housing with seamless front frame with flat non-yellowish diffuser to fix in existing POP including cutting/grouting of existing POP and get electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engineer-in-Charge. Make : Bajaj of Cat Part No BZRSQL 36W GZi WH or its equivalent as specified make
S&F in repairs of MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCB TP 40 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-Charge.
Taking down carefully the old U/S Aluminium / Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish Complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly Complete all as specified and directed by Engineer-in-charge. for following : Note:-(i) The rate is inclusive cutting /chasing and making good the disturbed surface with CM 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash (ii) In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbow/tee junctoin box etc .
One light / fan/bell point controlled by one switch SP, one way, 230 volts.
One 5 pin socket outlet 5/6 Amps on same board.
One 5 pin socket outlet 5/6 Amps on independent board.
One power socket 15/16 Amp independent board with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F in repairs distribution board vertical triple pole and neutral 4 way, double door for fixing MCCB upto 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MS fastner bolt 8mm dia and 100mm long for fixing Exhaust fan/Bldg security light etc with nut and washer complete all as specified and directed by Engineer-in-Charge.
Taking down geyser 25/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of heating element 1.5 KW for any make of geyser upto 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge. Make Micronking/Theeta/Standard
S&F in repairs of heating element 2 KW for any make of geyser 50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge. Make Micronking/Theeta/Standard
S&F in repairs thermostat for 25/50 ltrs capacity geysers complete all as specified and directed by Engineer-in-Charge. Make Micronking/Theeta/Standard
S&F in repairs of indicating lamp round / flat type as required for geyser 25/ 50 litres capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of safety valve ISI marked for geyser 25/50 litres capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs safety plug for geyser 25/50 litres capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connection with brass nipple 15 mm bore 450 mm long for geyser 25/50 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs base plate for geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 25 litres capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs base plate for geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 50 litres capacity sample complete all as specified and directed by Engineer-in-Charge.
S&F in repairs inner stainless steel tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engineer-in-Charge.
S&F in repairs inner stainless steel tank suitable for 50 Ltr storage water heater complete all as specified and directed.complete all as specified and directed by Engineer-in-Charge.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/50 ltrs capacity and make the shell water tight including testing complete all as specified and directed by Engineer-in-Charge. Note:-Taking down, de-scaling, replacement of rubber gasket and any minior repair involved will be mesured and paid seperatly.
S&F in repairs Rubber gasket for water heater storage of any capacity fixed and suitable as per the existing, complete all as specified and directed by Engineer-in-Charge.
M&L top & bottom cover body suitable for 25 Ltrs storage water storage heater made of MS sheet as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L top & bottom cover body suitable for 50 Ltrs storage water storage heater made of MS sheet as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs water lifting pump,single phase suitable for desert coolers complete all as specified and directed by Engineer-in-Charge. Make: Khaitan/Bajaj /Crompton Greaves.
S&F in repairs cooler fan motor 1/7 HP or any HP 230 volt,50Hz cycles A/C supply of make Summer Cool/ Hindustan /Havells complete all as specified and directed by Engineer-in-Charge.
S&F in repairs capacitor, 4 mfd rating complete all as specified and directed by Engineer-in-Charge. Make - Epcos/tibcon/universal.
S&F in repairs wood wool pad (set of 3) suitable for 18 inch sweep desert cooler of good quality complete all as specified and directed by Engineer-in-Charge.
M&L for refilling of gas in 1.5 Ton AC including necessary arrangement for gas filling.R-22 complete all as specified and directed by Engineer-in-Charge.
M&L for refilling of gas in 320 ltr capacity Deep Frzeer including necessary arrangement for gas filling R-134A. complete all as specified and directed by Engineer-in-Charge.
S&F in repairs compressor for deep freezer of capacity 320 ltr complete all as specified and directed by Engineer-in-Charge. Make:-Godrej/LG/Tecumseh.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and directed by Engineer-in-Charge.
M&L cleaning of semi under ground sump of storage capacity of water up to 25000 gallons thoroughly by removing mud, dirt etc. from the sump by the following method complete all as specified and directed by Engineer-in-Charge. Notes:- (a) Cleaning inner surface of the tank by scraping with steel wire brushes and removing mud and sludge collected in and outside of the tank and removing sludge to a distance not exceeding 50 meter. (b) Washing with clean water thoroughly complete tank internally and finally cleaning with bleaching powder. (c) writing date of cleaning on the sump.
S&F in repairs of GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, fixed in sewage well, U/G sump,borewells,concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows,flanges,Tee, short pieces,reducer,nipple, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), complete all as specified and directed by Engineer-in-Charge of the following sizes:-
100 mm bore
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
S&F in repairs of 150mm CI pipe class B with all fittings in any length laid in trenches/ fixed to wall including necessary excavation and returning filling complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of following items/accessories in existing position complete all as specified and directed by Engineer-in-Charge of the following sizes:-
GI union 100 mm bore
GI union 75/80 mm bore
GI union 40/50 mm bore
GI union 20/25 mm bore
GI socket 100 mm bore
GI socket 75/80 mm bore
GI socket 40/50 mm bore
GI socket 20/25 mm bore
GI elbow 100 mm bore
GI elbow 75/80 mm bore
GI elbow 40/50 mm bore
GI elbow 20/25 mm bore
GI End plug 40/50 mm bore
GI End plug 20/25 mm bore
GI Tee 80/50 mm bore
GI Tee 50/40 mm bore
GI Tee 25/20 mm bore
GI Flange 80 mm dia
GI Flange 50 mm bore
M&L for run lead joint for any bore suitable for spigot socket GI/CI pipe including taking down old unservicable lead joint and fixed in repair including necessary excavation work complete all as specified and directed by Engineer-in-Charge
M&L AL- TOCH-GP (Calcium based granular disinfectant) for water treatment in packing of 45 Kg drum of manufacture complete all as specified and directed by Engineer-in-Charge
M&L for cutting of existing CI pipe in trenches of size 150/100 mm bore for new branch connections including necessary excavation and earth work complete all as specified and directed by Engineer-in-Charge
M&L cutting of existing GI pipe in trenches of size 80/50/40 mm dia for new branch connections including necessary excavation and earth work complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable overload relay MN 4.5-7.5/ MN 6-10 /MN 9-15 Amps and connected internal wiring complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable overload relay MN 20-33 Amps and connected internal wiring complete all as specified and directed by Engineer-in-Charge Note:- for item no. 87 & 88 the rate is inclusive of connection out the starter before replacement of relay and make the connection after replacement of realy.
S&F in repairs of old unserviceable contactor MNX 18 Amps and connected internal wiring complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable contactor MNX 25 Amps and connected internal wiring complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable contactor MNX 32 Amps and connected internal wiring complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable contactor MNX 40 Amps and connected internal wiring complete all as specified and directed by Engineer-in-Charge Note:- For item No. 89 to 92 the rate is inclusive of connection out the starter before replacement of contactor and make the connection after replacement of contactor.
S&F in repairs of old unserviceable single phase preventor and connected internal wiring suitable for 10 HP motor starter complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable single phase preventor and connected internal wiring suitable for 15 HP motor starter complete all as specified and directed by Engineer-in-Charge Note:- for item No. 93 & 94 the rate is inclusive of connection out the starter before replacement of single phase preventorr and make the connection after replacement of single phase preventor.
S&F in repairs of old unserviceable phase sequence corrector relay 440V , 50 HZ suitable for 15 HP motor starter and connected internal wiring complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable phase sequence corrector relay 440 Volts, 50 HZ suitable for 10 HP motor starter and connected internal wiring complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable phase sequence corrector relay 440 Volts, 50HZ suitable for 7.5 HP motor starter and connected internal wiring complete all as specified and directed by Engineer-in-Charge Note:- for item No. 95 to 97 the rate is inclusive of connection out the starter before replacement of phase sequencer and make the connection after replacement of phase sequencer.
S&F in repairs of old unserviceabel digital voltmeter of range 0-500 volts and connected internal wiring suitable for submersible/booster/sewage motor starter complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceabel digital Ammeter of range 0-100 Amps and connected internal wiring suitable for submersible/booster/sewage motor starter complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable indication lamp in R,Y,B colour and connected internal wiringin for motor starter complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable Rotary switch and connected internal wiringin for motor starter complete all as specified and directed by Engineer-in-Charge
S&F in repairs of old unserviceable push button and connected internal wiringin for motor starter complete all as specified and directed by Engineer-in-Charge
Supplying, installation, testing and commissioning in replacement of LT panel 2.0 mm thick cubical indoor type weather proof, powder coated, totally enclosed with IP 65 protection made out of CRC sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 440 volts, 50 Hz including cable glands, phase indicators, internal wiring, voltmeter,suitable size of CT's, ammeter, with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys,and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering comprising of the followings complete all as specified and directed by Engineer-in-Charge
Supplying, installation, testing and commissioning in replacement of LT panel 2.0 mm thick cubical indoor type weather proof, powder coated, totally enclosed with IP 65 protection made out of CRC sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 440 volts, 50 Hz including cable glands, phase indicators, internal wiring, voltmeter,suitable size of CT's, ,ammeter, with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys,and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering comprising of the followings complete all as specified and directed by Engineer-in-Charge.
Supplying, installation, testing and commissioning in replacement of LT panel 2.0 mm thick cubical indoor type weather proof, powder coated, totally enclosed with IP 65 protection made out of CRC sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 440 volts, 50 Hz including cable glands, phase indicators, internal wiring, voltmeter,suitable size of CT's, ,ammeter, with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys,and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering comprising of the followings complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to starter panelall complete all as specified and directed by Engineer-in-Charge.
M&L for Lifting of submersible pumping set of any capacity from deep bore well with chain and pulley arrangement including lowering down the submersible pump set after repair complete all as specified and directed by Engineer-in-Charge.
M&L for complete overhauling/repair of defective submersible pump of 5-7.5 HP and replacement of following spares of pumps of capacity 5HP to 7.5 HP, 3 phase motor driven (excluding motor) cast iron/cast steel body complete and connecting with motor portion complete all as specified and directed by Engineer-in-Charge.
CI connection piece.
CI Stage bowl.
GM neck ring.
Remetling of GM impeller turning.
GM DOL bush.
SS stud with nut.
Water seal
Revolving disc
EPV Impeller.
Impeller key.
Repairing of stamping of stator.
CI DOL piece.
SS coupling with key.
CI Suction piece.
GM sand guard.
All as per Srl item number above herein before but 10-12.5 HP capacity complete all as specified and directed by Engineer-in-Charge.
CI connection piece.
CI Stage bowl.
GM neck ring.
Remetling of GM impeller turning.
GM DOL bush.
SS stud with nut.
EPV Impeller.
Impeller key.
Repairing of stamping of stator.
CI DOL piece.
SS coupling with key.
CI Suction piece.
GM sand guard.
M&L in replacement re-winding of motor of submersible pump set of 5HP to 7.5 HP capacity with suitable size copper conductor wire including insulating material and transportation of the repair motor of MES installation to workshop and back complete all as specified and directed by Engineer-in-Charge Note:- The quoted rate shall be deemed to be inclusive of transportation charges from site to workshop and back.
M&L in replacement re-winding of motor of submersible pump set of 10HP to 12.5 HP capacity with suitable size copper conductor wire including insulating material and transportation of the repair motor of MES installation to workshop and back complete all as specified and directed by Engineer-in-Charge Note:- The quoted rate shall be deemed to be inclusive of transportation charges from site to workshop and back.
S&F in repairs of following spares of motor of capacity 5 HP to 12.5 HP complete all as specified and directed by Engineer-in-Charge
GM bearing bush.
SS Tuter sleeve.
Cable seal.
Thrust bearing.
Thrust Plate
Sealing Ring.
Motor seal 10 mm
Motor seal 25 mm
O ring
CI Lower housing.
CI upper housing.
Remetling of rotar & turning.
S&F in repairs submersible cable flat 6 Sqmm 3 core for bore well of any depth with fitting and connections complete all as specified and directed by Engineer-in-Charge
M&L for Lifting of motor/ pumping set from the existing sewage well of any depth with chain and pulley arrangement and lowering down the motor/pumping set after repairing complete all as specified and directed by Engineer-in-Charge
Taking out Manhole cover and Desludging the existing manhole septic tank including removing of Sludge/Mud/Muck, Desilting/Dechocking with combine high pressure water jetting cum suction (Vaccum) type machine mounted on LCV/HCV and disposed off outside MoD land and blocking of the sewage line of septic tank to stop the entry of waste water/sludge/mud in sewage well complete all as specified and directed by Engineer-in-Charge
M&L for disposal of waste water up to 12 feet depth of Sewage well and 08 Feet depth of Man Hole by using Portable sewage pumping set of capacity 12 HP and filling of waste water in a covered trolley and disposed off outside MoD land complete all as specified and directed by Engineer-in-Charge.
M&L for removal of Sludge/Mud/Muck/Waste material/Silt upto a depth of 26 feet , Desilting/Dechocking with high pressure super socker machine and cleaning of surface of sump of sewage well using wire brushes and other scrapping tools to remove dirt and scales to make it free from all deposits and disposed of the same to outside MD land complete all as specified and directed by Engineer-in-Charge.
Opening of Manhole cover and connecting of the sewage line of septic tank with sewage well complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for nuts, bolts, rubber gasket complete set complete all as specified and directed by Engineer-in-Charge. Note : One job shall be inclusive of all nuts, bolts, washers and rubber gasket required for lifting/lowering of pipe line for one pumping set
M&L for preparation of monoblock pump of capacity up to 15HP at site and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of the monoblock pumpset of 5 HP to 7.5 HP capacity with suitable size copper conductor wire including insulating material and transportation of the repair motor of MES installation to workshop and back complete all as specified and directed by Engineer-in-Charge. Note:- The quoted rate shall be deemed to be inclusive of transportation charges from site to workshop and back.
M&L for rewinding of the monoblock pumpset of 12.5 HP to 25 HP capacity with suitable size copper conductor wire including insulating material and transportation of the repair motor of MES installation to workshop and back complete all as specified and directed by Engineer-in-Charge. Note:- The quoted rate shall be deemed to be inclusive of transportation charges from site to workshop and back.
S&F in repairs of following spares of booster pumping set of capacity up to 15 HP complete all as specified and directed by Engineer-in-Charge.
bearing
brass Impeller
Glands packing
Alignment of motor shaft including Lathe work complete all as specified and directed by Engineer-in-Charge.
S&F chlorine water testing chloroscope type kit for testing of water complete all as specified and directed by Engineer-In-Charge.
M&L for servicing to DG set of capacity up to 35 KVA as per manufacturers direction/description including oiling, cleaning & greasing complete all as specified and directed by Engineer-in-Charge. Note:- (Spares shall be measured & paid separately under respective item as M &L)
M&L in replacement of oil filter set for 20 to 35 KVA DG set complete all as specified and directed by Engineer-in-Charge.
M&L in replacement starter key switch for 20 to 35 KVA DG set complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of Battery Terminal made of brass nut & bolt complete all as specified and directed by Engineer-in-Charge.
Repair and calibration to fuel injection pump & nozzle for 20 to 35 KVA DG set complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of fuel filter set for 20 to 35 KVA complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of pipe (Fuel line) set for 20 to 35 KVA complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of radiator hose pipe set for 20 to 35 KVA complete all as specified and directed by Engineer-in-Charge.
M&L in replacement engine oil as per manufacturers suggested grade complete all as specified and directed by Engineer-in-Charge.
Topping up of coolant complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of temperature gauge for DG Set complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Off load Changeover Switch- in sheet enclosure, 50 Hz. 4 pole 100 Amp, 415 volts on load side handle operated type inclduing taking down old change over complete all as specified and directed by Engineer-in-Charge. Make:- Cat Part No IHBFFE0100 of Havells or its equipvalent HPL/L&T/Standard.
S&F in repairs gunmetal globe or gate valve/sluice valve for 150 mm (6 inch) bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge.
S&F in repairs gunmetal globe or gate valve/sluice valve for 100 mm (4 inch) bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge.
S&F in repairs gunmetal globe or gate valve/sluice valve for 80 mm (3 inch) bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge.
S&F in repairs gunmetal globe or gate valve for 40 mm bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge.
S&F in repairs gunmetal globe or gate valve for 25mm bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge.
S&F in repairs gunmetal globe or gate valve for 50 mm bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge.
S&F in repairs and testing of Foot Valve confirming to IS 4038 complete of size 80mm (3") dia in replacement of old u/s foot valve complete all as specified and directed by Engineer-in-Charge.
S&F in repairs connect and test, Valve, reflex (non return), with bypass arrangement complete of size 150mm dia (6") dia including all fixing materials like rubber gasket, nuts, bolts, washer etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs connect and test, Valve, reflex (non return), with bypass arrangement complete of size 100mm dia (4") dia including all fixing materials like rubber gasket, nuts, bolts, washer etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs connect and test, Valve, reflex (non return), with bypass arrangement complete of size 80mm dia (3") dia including all fixing materials like rubber gasket, nuts, bolts, washer etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs butterfly valve for 80 mm bore pipe, with iron wheel head screwed both end complete all as specified and directed by Engineer-in-Charge. Make Leader/Jindal/Sant
S&F in repairs of battery 180 Ah,12 Volts maintencance free including battery termail alongwith connectiing wire of suitable gauge upto 2 mtr length min as required on site complete all as specified and directed by Engineer-in-Charge. Make:- Exide/Amaron/ Luminious.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified and directed by Engineer-in-Charge.
M&L for construction of valve pit of size 100 cm x 100 cm x 110 cm (internal dimensiions), stone/ brick construction, including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to distance not exceeding 50 m and depositing where directed, PCC in foundation of the mix (1:2:4) type D-2, brick masonary in cement mortor (1:4) rendering 12 mm duck in cement mortar (1:4) internally, finished even and smooth and pointing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the that as approved by the GE over a cost of red oxide primer and painting all the MS embedded in PCC with two coats of black bitumenous paint and complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ball brass valves of 25mm ,high pressured,with polythene float, flynut,screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
PD SHARMA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .