Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹41.1 L+₹3.6 L (9.52%)Rejected-AOC | L2 | Rejected-AOC 2ND LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical REJECTED | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACMENT OF HT SWITCH GEARS CABLES POLES CHANNELS AND FIRST LINE MAINT ASSETS OF HV LV GRIDS YARDS AT GMS
2020_MES_359708_1
8000/17/20-21/0916/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GARRISON ENGINEER I GOS
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹70,000
Yes
18 Nov 2020
9 Jul 2020
15 Aug 2020
9 Jul 2020
13 Aug 2020
28 Jul 2020
60 days
Amount
M&L for first-line maint of overhead bus bar grid/ 2 pole str/ 4-pole/ Sub Stn yard structure by checking out the jumpers/discs/ LAs/connectors e t c and locating the fault and replacing with necessary Conductor for jumpers/ clamps & connectors/ LAs /Disc/Pin insulators / clamps etc, making good, cleaning and lubricating the mobile parts etc complete all as specified and as directed : Note : Conductors for jumpers, disc/pin insulators, LAs are measured and paid separately under relavent items
Scrapping/cleaning of outer surface of transformer and spray painting with two coats of best quality synthetic enamel paint over of red oxide primer complete including writing of MES NO/SM NO upto 315 KVA capacity transformer of any make/shape/size complete all as specified and directed.
Scrapping/cleaning of outer surface of transformer and spray painting with two coats of best quality synthetic enamel paint over of red oxide primer complete including writing of MES NO/SM NO above 315KVAand upto 650KVA capacity transformer of any make/shape/size complete all as specified and directed.
Supply and install HT 11 KV 3 phase 50 cycles out door type air break switch suitable for horiandal/Vertical mounting fixed type complete with 9 insulators operating handle and all clamps,nuts,bolts etc of rating upto 200 Amp all as specified and as directed
S & F in repair horn gap fuse 11 kv triple pole, horizontal type for outdoor use including all accessoreis complete all as specified and as directed
S & F lighting arresters expulsion type complete with all fittings transmission class discharge capacity 65 kilo Amp all accessoreis complete all as specified and as directed
Supply and fix Male contact /moving contact blade for GOS
Supply and fix Female contact/fix contact jaw for GOS
Supply and fix Tinned copper flexible jumper for GOS
Supply and fix MS jumper carrier for GOS
Supply and fix Back connector plate for GOS
Supply, only fuse wire tinned copper of diff capacity completeall as specified and directed..
Supply, and fix in replacment of breather with silica gel complete all as specifed and as directed..
Supply & fix replacement of silica gel completeall as specified and directed..
Supply & fix replacement of petrolium jelly completeall as specified and directed..
Painting of two pole stucture consistig of 2 Nos PCC pole 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed
Painting of two pole stucture consistig of 2 Nos (Metal Strucure) 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed
Painting of four pole stucture consisting of 4 Nos pole(metal structure) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed
Painting of four pole stucture consistig of 4 Nos pole(PCC) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed
Taking down defective transformer upto 650 KVA capacity from pole/structure/sub-station after disconnecting the connection and removing to sub-station then transporting the same to a reputed work shop for repairs.After repairing the same transporting back the repaired transformer(including loading and unloading) to the directed lacation.After installing the transformer connection of LT and HT has to be done complete all as specified and directed.
S&F high voltage coil of transformer including double paper insulated conductor of same gauge as per existing and all insulating material,varnishing and he complete all as specified and directed.ating with vaccum impregnation and baking of coil suitable upto 650 KVA transformer complete all as specified and directed.
S&F low voltage coil of transformer including double paper insulated conductor of same gauge as per existing and all insulating material,varnishing and he complete all as specified and directed.ating with vaccum impregnation and baking of coil suitable upto 650KVA transformer complete all as specified and directed.
De-hydration and filtration of transformer oil by using dehydration and filtration plant, heating and filtration of oil to be casrried sout till the di-electric strength reaches 40 KV to 60KV withstand for one minute is achieved, for any capcity of tranformer from 50 to 500 KVA or OCB of any type and capacity all as specified and as directed
Topping up/replacement of transformer oil of transformer chamber and conservator with new transformer oil upto a required level (of 60KV di-electric strength to withstand for one minute) in any type and capacity of tranformer/OCB all as directed by Engineer-in-Charge (Make : POWER/ CASTROL/ HP/SERVO/ ELECTROL)
Supply & fix replacement of top cover gasket of transformer suitable for any type/make/capacity upto 650KVA(make up of cork sheet 5mm thick) completeall as specified and directed..
Dismantling of HT bushing of transformer including metal parts and rubber parts and replacing with new bushes complete with new metal and rubber parts of any size and shape required for transformer upto 650KVA completeall as specified and directed..
Dismantling of LT bushing of transformer including metal parts and rubber parts and replacing with new bushes complete with new metal and rubber parts of any size and shape required for transformer upto 650KVA completeall as specified and directed..
M&L for brickwork with Fly ash bricks,straight or curved on plan exc 6m mean radiusbuilt in cement mortar1:6 complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of bricks work or concrete surfaces in cement plaster 1:4 complete all as specified and directed.
Supply and spreading 40mm graded stone aggregate complete all as specified and directed.
Surface dressing n.exc 30 cm deep and average 15 cm deep and getting out in any type of soil.
M&L for repair and caliberation of VCB any type/cap upto 630A cap indoor HT panel with replacment of minor spares/ auxilary contacts of manual closing/charging mechanisam, motorised charging spring and connected mobile parts, check for healthy trip mechanism, closing coil, tripping coil, auxilary contacts, replacment of PVC/Fibre insulator, rectifing the earth fault of the bus bar contacts and protective relays and complete caliberation of VCB complete testing and all as specified and as directed
M&L for Danger notice plate made of sheet molding composite (SMC) with red white with letters figures and conventional skull and in bones in signal red colour of HV Size and fixed with GI clamps bolts and nuts for 11 KV /HV Installations complete all as specified and as directed
M&L for Danger notice plate made of sheet molding composite (SMC) with red white with letters figures and conventional skull and in bones in signal red colour of LV size and fixed with GI clamps bolts and nuts for 415V/LV Installations complete all as specified and as directed
Making of name board with 6mm thick PVC board , font not more than 50mm size (sticker type computer font/print/sketch) for line diagram showing the HT Supply distribution of pocket sub stations all as specified and as directed for wall fixing duly framed with suitable fixing arrangements etc (Note : Draft of drg/sketch be obtained from this office and get approved by the Engr-in-Charge before placing the order)
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5M deep for foundation/cable trench, not exceeding 10 Sqmm on plan and getting out in soft/loose soil all as specified and directed.
Returning filling including spreading, levellingand well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed..
Supply , spreading and punning river sand for cushoining to cables in trenches , cable ducts , yards e.t.c complete all as specified as per SSR Part - I of 2009 and directed.
Taking out electric power cable of any size and make heavy duty with alumnium conductor, 11000 volts grade by excavating in trenches, removing cable protection covers etc complete all as specified and as directed
Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, gaivanised steel strip or wire armoured, electric power cable heavy duty with alumnium conductor, 11000 volts grade ISI marked of size 3 core cross section area 95 sqmm complete all as specified and directed.
Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, gaivanised steel strip or wire armoured, electric power cable heavy duty with alumnium conductor, 11000 volts grade ISI marked of size 3 core cross section area 120 sqmm complete all as specified and directed.
All as per item above but of size 3 core cross section area 70 sqmm complete all as specified and directed.
Relaying only of any size of electric power cable heavy duty with alumnium conductor, 11000 volts grade complete all as specified and directed.
Supplying & laying of precast concrete cable cover, class HV, type 1 peak type size 300mmx180mmx40mm complete all as specified and directed..
Supply, jointing and testing of cable jointing kit for 11 KV(earthed) grade cable out door termination heat shrink type joint complete with jointly material and accessories suitable for 3 core under ground XPLE armoured aluminium conductor cable of size 70 to 95 sqmm complete all as specified and directed..
Supply, jointing and testing of cable jointing kit for 11 KV (earthed) grade cable straight through termination heat shrink type joint complete with jointly material and accessories suitable for 3 core under ground XPLE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed..
Supply, jointing and testing of cable jointing kit for 11 KV (earthed) grade cable straight through termination heat shrink type joint complete with jointly material and accessories suitable for 3 core under ground XPLE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and directed..
Supply, jointing and testing of cable jointing kit for 11 KV(earthed) grade cable out door termination heat shrink type joint complete with jointly material and accessories suitable for 3 core under ground XPLE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed..
Supply & Fixing in replacement precast PCC cable route indicator duly marked and painted for HT /LT cable of size 80 x 25 x 7.5 CM with suitable size of base complete all as specified and as directed.
M&L in repair mild steel work for Cross arms, /angle supports bracings, supports, clamps and black plates fabricated from structural steel section including nuts, bolts, washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking out existing u/s MS work complete all as directed.
S&F in replacement of Old unsv cable loop box with PVC box of double hinged door to accommodate 6 amps MCB fixed ondin-rail, 4P connecter complete incl necessary clamps, bolts, nuts complee all as specified and as directed (Syntex/hensel)
M/s Bapujee Builders and Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .