Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | ₹7.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.0 LRejected-Finance CHAMARBANDH NAYAGRAM DISTRICT JHARGRAM PIN 721506 | NAYAGRAM | JHARGRAM | WEST BENGAL | 721506 | ₹7.0 L | L2 | Rejected-Finance L2 |
| 3 | L3₹7.0 LRejected-Finance MAHATABPUR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR WEST BENGAL PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | ₹7.0 L | L3 | Rejected-Finance L3 |
Tender Value
₹7.0 L
EMD Value
₹13,996
Closing Date
27 Jan 2026, 2:00 pmClosed
CMOH and Secretary, Jhargram
CMOH Office, Jhargram
Conversion of Rural SHCs to SSK-HWC at Bardanga SC under Jhargram Block, Jhargram District.
2026_HFW_984386_3
DHFWS/JGM/2025/64
Open Tender
CIVIL AND ELECTRICAL WORKS
Bardanga SC under Jhargram Block, Jhargram Distric
Please refer Tender documents.
3 documents required · 3 mandatory
₹13,996
Yes
24 Feb 2026
13 Jan 2026
29 Jan 2026
13 Jan 2026
27 Jan 2026
13 Jan 2026
Civil Works
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.-In ground floor including roof.
Do- In Ground Floor
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars-In ground floor including roof.
Do- In 1st Floor
Taking out Mirzapur or glazed porcelain tiles carefully by chiselling from walls or floor including stacking serviceable material as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75 m. as directed. .- Depth of excavation not exceeding 1,500mm.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety]
250 mm thick Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, 1st floor
Do- In Ground Floor
125 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor.
125 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in 1st floor.
Hire and labour charges for shuttering with necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing...25 mm to 30mm wooden shuttering (in Gr. Floor)
Do- In Ground Floor
Ordinary Cement Concrete (mix-1:1-5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any, in 1st floor as per relevent IS codes. (i) With Pakur Variety
Do- In Ground Floor
Reinforcement - In 1st floor(JSW/JSPL/ SHYAM/SRMB/BMASL ELECTROSTEEL/ SSL
Do- In Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Gr. floor). (i) With 1:6 cement mortar (b) 15 mm thick plaster
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (1st floor).[Excluding cost of chipping over concrete surface (i) With 1:6 cement mortar (b) 15 mm thick plaster
10mm thick ceiling plaster (1:4)- In 1st Floor
Do- In Ground Floor
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. ….. (In ground Floor)
Do- In 1st Floor
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.- In Ground Floor
Do- In 1st Floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors….(B) Wall -With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry ...- Area of each tile upto 0.09 Sq.m- Other than Coloured decorative including white- In ground floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors….(B) Wall -With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side ....- Area of each tile above 0.09 Sq.m- Other than Coloured decorative including white- In 1st floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors…-With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m- In FLOOR Ground floor-Area of each tile Upto 0.09 Sq.m- Other than Coloured decorative including white
(a) M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S.,W.I Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs- Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.- In 1st Floor
Do- In Ground Floor
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm carriage of all materials, taxes and
Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of which 75mm shall be flat and 20 mm (1st fl.)
Do- In Ground Floor
Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.
Welding in M.S. structural work with gas or electric:- (a) Tack weld
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. _in Ground Floor (Two Coat)
Do- In 1st Floor
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
Do- In 1st Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC-One Coat-Water based interior grade Acrylic Primer
Do- In 1st Floor
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary :
Supplying, fitting & fixing granite slabs ......... [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]- Area of each Granite slab 0.6 to 1.0 Square meter.
18 mm. to 22 mm. thick, kota stone slab set .....[Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Supplying, fitting and fixing in position fibre glass panes of approved quality with resin, nail, clip etc. as per IS:12866-1989.
Sanitary & Plumbing Works
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc...
(i) For Exposed Work- 20 mm
(ii) For Concealed Work-20 mm
Labour for hoisting plastic water storage tank.
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.
(iii) 630 mm X 450 mm size
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a)Sink Only.
(ii) 530 mm X 430 mm X 180 mm
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.
b) PTMT (polytetra Bib cock/stop cock) - 15 mm. (Prayag or equivalent
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.ii) Polythene Flush Pipe
Supplying, fitting and fixing porcelain soap tray of approved make
CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand).
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
UPVC Fittings
Plain Tee-110 mm
Plain Y-110mm
Bend 87.5º-110mm
Bend 45º-110mm
Pipe Clip -110mm
Vent Cowl-110mm
Socket Plug -110mm
Supplying, fitting & Fixing closet seat of approved make with lid and CP, hinges, rubber buffer and brass screws complete, EWC plastic(hallow type) white.
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the EIC.- Above ground- 110 mm dia.
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap -580mmx440mm
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.- 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets.-C.P. over brass-25 mm dia. and 600 mm long
Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.- Upto 20 users-Beyond a lead of 150 metre and outside the Municipal limit
Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab.
Cleaning silt of master trap pit.
Electrical Work
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. 25mm Size
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.
2 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [1(b). / E-11]
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [1(c). / E-11]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface]
Average run 6 mtr (Sub. Item No. : (b))
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
6-20 A SP MCB [Make - Legrand / Schneider] (Page No. D 6 item No.7) [ 1st Floor and Ground Floor SPN MCBDB ]
Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 6A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9")
Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long ) For Al : 23 cm Exhaust fan (9")
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long ) or as reqd. Incl. S&F 24/0.02 PVC insulated Flexible copper wire 0.5 mt.length (C-4/29)
Supply & Fixing full Metal body AC Cabin fan 16" sweep with net guard and all accessories ( Make EPC Tempest / cinni / CG) ( Rate taken from PWD Executive Engineer vetting Estimate)
Supply of 48 inch sweep ceiling fan Similar to --Orient New Breeze/Summer King/Usha-Striker make (Rate Analysis at SPMU )
Supply of 09 inch sweep heavy duty exhaust fan Similar to---EPC make/Orient
Supply & delivery of single 4ft Batten type LED tube light fitting, 1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Havells: LED Pride Plus NXT Batten 22 W 6500 K) or equivalent of Philips, Crompton etc. [Approved by EIC]
Supply & Delivery at site 9 watt LED Bulb [Make-Crompton] or equivalent of Havells, Philips etc. [Rate Analysis at SPMU]
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
Fixing only lamp
Labour Welfare Charges 1%
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.62 MB
Tendernotice_2.pdf
PDF • 1.14 MB
BOQ_2404260.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid