Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPT | |
| 2 | Rejected-Technical COIMBATORE CORPORATION | COIMBATORE | COIMBATORE | TAMIL NADU | - | Rejected-Technical Technically Not Qualified |
Tender Value
₹27.5 L
EMD Value
₹27,500
Closing Date
11 Feb 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner, Coimbatore Corporation
Coimbatore Corporation, Main Office, Big bazaar street, Town hall, Coimbatore-1
Annual maintanence of voc botanical park (5.96 acres) 1 nos for a period of one year (12 months) in ward No 83 in Central Zone .
2025_MAWS_521502_3
E2/2025 TWO COVER
Open Tender
Civil Works
Works
365 days
Coimbatore corporation
AS PER TENDER DOCUMENT
4 documents required · 4 mandatory
₹0
₹27,500
9 Jul 2025
29 Jan 2025
12 Feb 2025
29 Jan 2025
11 Feb 2025
29 Jan 2025
Amount
Maitanence and cleaning works of parks by engaging sweeper worker keeping the park clean with cutting the tree branches and cleaning the bushes etc.,completed including ESI 3.25 %,Employer contribution for (EPS 8.33 % ,EPF 3.67%,EPF admin 0.50% and EDLI 0.50% PWD 2024-2025(Mazdoor category II-587 added 10%)
As per DMA Circular ROC No.21787/2021/EA2 dt.02.10.2021 ) Service charge to the Manpower supply agency (7 % )
Maintanence and cleaning works for parks with supply of cleaning materials such as broom stick,water transfer tube (50 mtr),aluminium bucket (4 nos),including supply & spraying of bio-pesticades (once in three months ) and supply of neem cake (once in three months)etc..,complete keeping the park clean.(material to park maintanence as per market rate 2024-2025)
Engaging man power of plumber including ESI 3.25%,Employer contribution for (EPS 8.33%,EPF 3.67 % and EDLI 0.50%),basic rate (PWD 024-2025) Plumber category -II rate-922/-added 10%)
As per DMA Circular ROC No.21787/2021/EA2 dt.02.10.2021 ) Service charges to the man power supply agency (7% of basic rate (PWD 024-2025) Plumber category -II
Engaging man power of Electrician including ESI 3.25%,Employer contribution for (EPS 8.33%,EPF 3.67 % and EDLI 0.50%),basic rate (PWD 024-2025) Electrician category -II rate-902/-added 10%)
As per DMA Circular ROC No.21787/2021/EA2 dt.02.10.2021 ) Service charges to the man power supply agency (7% of basic rate (PWD 024-2025) Electrician category -II
Lifting / Removal of Submersible Pumpset and its accessories from the Borewell for attending repairs etc., complete as per the direction of the departmental officers.
Flushing of borewell of 6" dia requiring less than 4 hours operation using drill rods / hose with required size of pipes for various capacity compressor including transportation, labour and fuel charges for compressors etc., complete as per the direction of the departmental officers.
Supply of GI Pipes with Specials.,
50 mm GI pipe ‘B’ class ISI mark
50 mm GI Bore Heavy Coupling
50mm dia UPVC pipe
50mm dia PVC pipe
Labour for the erection of submersible pumpsets in borewell including fixing and jointing submersible cable with proper claps upto the starter to the required depth and also fixing of riser pipes to the required depth values erection clamps, pressure gauges upto exterior wall of the pump room and erection of panel board consisting of TPICN, Switches starter, Voltmeter, Ammeter 3 pilot (including lamps) capacitor, single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules including construction of earth pits with earthing materials as per rules etc. complete Schedule (Item No. 17 C)
Supply and delivery of Three phase submersible motor pumpset with vertical type with all accessories with latest FS 8034 in general for the following duty conditions the pumpset should have diagonally balanced bronze impler and stainless shaft for motor and pump and directly coupled to a suitable capacity continuous rated three phase fifty cycles 22/440 volts AC supply motor should be as per ISI with upto date amendment. The starter winding should be made from high conductivity PVC insulated 3 core flat copper cable of suitable size of work Duty 200 LPM x 125 M head..
Supply and laying of following sizes of Armoured Aluminium/ Copper Cables for electrical motor, control panel,pressure switch, jockey motor etc., all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc.,complete as per standard specification and as directed by the Departmental Officers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT. .(pwd 24-25)
Supply and fixing of designing fabrication, powder coating assembling wiring, testing and supply of double door type EB metering panel board 3ph/63A 1 no. for suitable for 10hp sumbersible motor start delta with 2 leval guard (Rain proof model) as per Dept. instruction etc. complete.
15.Solid PVC Door Shutters using 19 Gauge 19mm MS squaretubes for styles and outer frames. 15mm MS square tubesfor top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter
Wiring with 2x1.5 sq.mm (22/.3) PVC insulated unsheathed Sc.Cu. conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with pvc accessories with TW switch box with 5A.F.T. switch inflush with all covered with hylem sheet of 3mm thick with painting of suitable colour for open pvc light point/fan point (SD 22) pg.no 13 electrical data 24-25
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unshealthed Cu.Conductor of 1100V grade in Suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with 150x100x113mm TW switch Box for 5 A 3 pin non inter locking CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point SD NO:39 pg no 23 electrical data 24-25
Supply and fixing of 1200mm (48") AC ceiling Fan completed with stepped eletronics 300W regulator with 1 meter down rod on thr existing clamp SD.NO:107 pg no 50 electrical data 24-25
Supply and Fixing of 3seater steel Bench for labour charges,Loading unloading charges etc complete,
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .