Ex Engineer ED-1st Srinagar
Office of the Ex Engineer ED-1st Srinagar BASANT BAGH
Renovation and Modernization of 100 KVA Substation at Check Sangri Khunmoh-C
2023_PDD_221176_1
EDI No 028 of 2023-24
Open Tender
Electrical Works
Lump-sum
15 days
SRINAGAR
Please refer Tender documents.
5 documents required · 5 mandatory
₹200
Yes
Ex Engineer ED-1st Srinagar
₹4,100
Yes
7 Aug 2023
12 Jul 2023
5 Aug 2023
12 Jul 2023
4 Aug 2023
12 Jul 2023
12 Jul 2023 - 13 Jul 2023
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles with pit excavation [(ST-410 SP33]
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [(ST-410 SP15]
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor
Providing and fixing of GI i)Channel iron (100x50x6)mm 8.5ft long 2No's alongwith braces ii)Channel iron (75x40x6)mm 8.5ft long 7No's alongwith braces iii)Channel iron (75x40x6)mm 5.5ft long 2No's alongwith braces iv)Channel V-Cross arm (75x40x6) mm 5.5ft. Long 2 No's alongwith F-Top & Back clamps (1.5 / Kg) v)Angle Iron belt for Transformer (50x50x6)mm 9ft long 2 No
Supply,installation, testing and commissioning of 185 mm² (2Ckt) Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type (Havells/Gloster/Polycab or Equivalent)
Supply,installation, testing and commissioning of 11kV G.O. AB Switch 3-Phase, 3-Pole 200A Vertical Type.
Supply,installation, testing and commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply,installation, testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply,installation, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply,installation, testing and commissioning of 16kN Polymer Shackle Insulators with GI U-Clamps
Supply,installation, testing and commissioning of Galvanized Nuts & Bolts of sizes
Earthing of substation - Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply,installation, testing and commissioning of Alumunium thimbles of sizes
Supply,installation, testing and commissioning of Anti Climbing Devices with clamps
Providing and fixing of Danger Plate
Providing & fixing of Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm
Providing and painting of 9/8 Mtr ST poles with two coats of red oxide and two coats of aluminium paint
Providing and laying of Cement bottoming 1:2:4 mix as per Standards 0.5cum /pole for 9 mtr Poles
Providing and laying of Cement bottoming 1:2:4 mix as per Standards 0.45cum /pole for 8 mtr Poles
M/s NORTHERN ELECTRICALS
BUDOO ELECTRICALS AND SUPPLIERS
M/S KHAN ENTERPRISES
M/S YOUSUF ENGINEERING WORKS
Laiba electrical Suppliers and mechanical work
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .