Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC 42 B INDRA NAGAR SRINAGAR J K 190004 | SRINAGAR | SRINAGAR | J K | 190004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.4 L+₹1.5 L (7.04%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹23.6 L+₹1.7 L (7.71%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹25.3 L+₹3.4 L (15.6%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
Tender Value
₹29.7 L
EMD Value
₹59,380
Closing Date
12 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
REPAIR MAINT OF HEATING AND COOLING PLANTS INCLUDING CONNECTED ACCESSORIES AND LAUNDARY AND INCINERATOR SYSTEM AND ALLIED WORKS AT BB CANTT UNDER GE 864 EWS
2023_MES_618659_1
CWEK-38/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 874 EWS
Class D Category c i
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹59,380
Yes
HQ 133 WORKS ENGRS
28 Dec 2023
13 Sept 2023
20 Oct 2023
13 Sept 2023
12 Oct 2023
29 Sept 2023
13 Sept 2023 - 23 Sept 2023
24 Sept 2023
Amount
S&F new boiler coil of capacity 2 to 4 Lac Kcl/Hr with precision workman ship using Tripod and chain pulley and inserting the coil inside combustion chamber by dismanteling and opening of boiler including reassembling the top cover plate and glycol tubing complete with electrical connections and testing of the same complete all as directed by Engr-in-Charge.
M&L for dismantling and Isolating burnt blower motor from AHU (Air handling unit) by disconnecting all electrical and mechanical connections and rewinding of motor and reassembling, testing of the same after carrying out rewinding of blower motor of capacity 5 to 7.5HP, 3ph 415Volt, 50Hz with supper enamelled copper wire having same gauge after taking out old burnt winding including replacement of bearing complete all as directed by Engr-in-Charge.
M&L for replacement of gasket set of pump set as per site requirement complete all as directed by Engr-in-Charge.
M&L for descaling of boiler coil and including cleaning inside of chamber along with de corbonization of combustion chamber of complete system under mentioned boiler coils and servicing of boiler by opening of boiler coil cover from the both sides including disconnecting of inlet and outlet water connections of the boiler. Removing scale/sludge precipitated in the tubes by push and pull method with iron rod connected with steel wire brush of suitable size as per copper tube size for the entire length of coil and scraping down the sludge precipitated inside the tubes. Closing both side of coil and circulating the descaling compound solution in tubes of boiler through the separate circulating pump and allow the descaling solution to hold for 1hr for chemical reaction. After the duration of 1 hr open the coil ends and clean with iron rod connected with nylon brush of suitable size as per tube size and ensuring that the coil has been descaled upto max clean range , then closing both the ends of the coil and circulating clean water in the tubes of boiler and draining it out, the process will be continued till the satisfaction of Engr-in-Charge then refixing the coil inside the chamber complete with all fixing material required at site:- 70000 K cal/hr to 110000 K cal/hr complete all as directed by Engr-in-Charge.
All as per item No 4 but of cap 200000 KCl/Hr at 31 Sub area / 216 Transit camp complete all as directed by Engr-in-Charge.
All as per item No 4 but of cap 300000 KCl/Hr at sand modal room, 216 Transit camp complete all as directed by Engr-in-Charge.
All as per item No 4 but of cap 400000 KCl/Hr at Family ward complete all as directed by Engr-in-Charge.
M&L for dismantling of oil fired stand alone Air Heating System for servicing and including cleaning inside of chamber along with de carbonization of combustion chamber of complete system of capacity 22000 - 50000 Kcl/Hr by isolation of burner unit assembly from main chamber of air heater and reassembling, testing of the same after carrying out following repair / replacement of under mentioned worn out parts including testing complete all specified and directed by Engr-in Charge. Note:- Spares shall be measured and paid under respective item
S & F in replacement Nozzle of suitable size 0.5 to 1.5 GPH at 60 degree suitable for burner of capacity 22000 to 50000 Kcal/hr complete all as directed by Engr-in-Charge.
S & F in replacement Sequence controller suitable for burner of capacity 22000-50000Kcal/hr complete all as directed by Engr-in-Charge.
S & F in replacement Fuel filter element suitable for burner of capacity 22000-50000 Kcal/hr (as per sample) complete all as directed by Engr-in-Charge.
S & F in replacement Thermostat switch suitable for burner of capacity 22000-50000 Kcal/hr complete all as directed by Engr-in-Charge.
S & F in replacement Fuel feed pump suitable for burner of capacity 22000-50000 Kcal/hr complete all as directed by Engr-in-Charge.
S & F in replacement Heavy duty wiremesh bounded fuel pipe with flare nut both ends as per sample complete all as directed by Engr-in-Charge.
S & F in replacement Electrode set as per sample complete all as directed by Engr-in-Charge.
S & F in replacement High temperature ignition cable complete all as directed by Engr-in-Charge.
S & F in replacement Ignition Transformer suitable for burner of capacity 22000 - 50000 Kcal/hr complete all as directed by Engr-in-Charge.
S & F Photo cell suitable for burner of capacity 22000-50000 Kcal/hr complete all as directed by Engr-in-Charge.
M&L for dismantling of Centralized hot water generators for servicing of capacity 70000 K cal/hr to 110000 K cal/hr by disconnection of all water and electrical connections isolating burner unit assembly from main boiler unit for repair work and reassembling, testing of the same complete all as specified and directed by Engr-in Charge. Note:- Spares shall be measured and paid under respective item)
S & F in replacement Nozzle of size 1.5 to 2.5 GPH at 70 degree suitable for burner upto capacity 70000 - 110000 Kcl/H complete all as directed by Engr-in-Charge.
S & F in replacement Sequence controller suitable for burner of capacity 70000 - 110000 Kcl/H complete all as directed by Engr-in-Charge.
S & F in replacement Fuel filter element suitable for burner of capacity 70000 - 110000 Kcl/H as per sample complete all as directed by Engr-in-Charge.
S & F in replacement Thermostat switch suitable for burner of capacity 70000 - 110000 Kcl/H complete all as directed by Engr-in-Charge.
S & F in replacement Fuel feed pump suitable for burner of capacity 70000 - 110000 Kcl/H complete all as directed by Engr-in-Charge.
S & F in replacement Heavy duty wiremesh bounded fuel pipe with flare nut both ends as per sample complete all as directed by Engr-in-Charge.
S & F in replacement High temperature ignition cable suitable for burner of capacity 70000 - 110000 Kcl/H complete all as directed by Engr-in-Charge.
S & F in replacement LED Display unit (subzero) with control wiring complete all as directed by Engr-in-Charge.
S & F in replacement main combustion chamber including coils of capacity 10000 to 200000 KCl/Hr complete all as directed by Engr-in-Charge.
M&L for servicing of cental type AC plant of capacity 11 TR to 30 TR complete system along with connected out door unit/ AHU system installed at various installation cleaning of condensing unit checking of all wiring if found damaged repalce the damage all wiring any type as per existing complete all as directed by Engr-in-charge.
Supply and filling of refrigerant of R-410A/R-22/R-32 in cooling plant installed at installation complete all as directed by Engr-in-Charge.
Supply and fixing Air flow per filter/fine filters metallic body box type as per existing sample complete all as directed by Engr-in-Charge.
M & L for Servicing of all type FCU like wall mounted type and celling mounted type any size any capacity including chemically wash,cleaning of filtter, fan,replacement of defected part like blower connection pipes,bearing,etc complete all as directed by Engr-in-Charge.
M & L for Servicing of FCU wall mounted type any size any capacity installed at dentel unit for VRV type heating and cooling plant including camical wash,cleaning of filtter, fan,replacement of defected parts like blower, connection pipes winding,bearing,etc complete all as directed by Engr-in-Charge.
M & L for Servicing and cleaning of packaged type AC plant of capacity 8 TR to 11 TR along with connected accessories like FCU/diffuser/grill system including chamical wash,cleaning of filtter, fan,replacement ofdefected minor parts like blower connection pipes winding,bearing,etc complete all as directed by Engr-in-Charge.
S & F for Three Phase Contactor 63 Amp 415Volt all conection complete all as directed by Engr-in-Charge.
M & L for repair Iron Sutter of E&M installations complete all as directed by Engr-in-Charge.
M & L dismantling the steam boiler coil & descaling of steam Boiler 600 Kg/Hr by opening of boiler coil cover from the both sides including disconnecting of inlet and outlet water connections of the boilder. Closing both side of coil and circulating the descaling compound solution in tubes of boiler through the separate circulating pump and allow the descaling solution to hold for 1 hr for chemical reaction. After the duration of 1 hr open the coil ends and ensuring theat the coil has been descaled upto max clean range. then closing both the ends of the coil and circulating clean water in the tubes of boiler and draining it out, the process will be continued till the satisfaction of Engr-in-Charge then refixing the coil inside the chamber complete with all fixing material required at site by the Engineer-in-Charge.
Supply & fixing in replacement of photo cell complete with holder complete all as directed by Engr-in-Charge. Model-8205 make ECEE Thermax
Supply & fixing in replacement of ignition transformer (14500V) complete all as directed by Engr-in-Charge. Make: Danfoss
Supply & fixing in replacement of pressure gauge 4" dia connection centre back mount, dial range-20 Kg to 25 Kg as per samble complete all as directed by Engr-in-Charge.
Supply & fixing in replacement of temprature gauge dia 2" connection centre back temperature orad as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of electric hooter for boiler 600 Kg/Hrs as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of heavy duty steam pressure gate/ball valve 15 to 25mm dia as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of heavy duty NRV valve 15 to 25 mm dia, as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of cooper tube dia 8mm/12mm as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of heavy duty inlet/outlet hose pipe with wire mesh of any size and any length as per sample complete all as directed by Engr-in-Charge.
M&L for rewinding of burnt motor front respective laundry/CHS machines by disconnecting all electrical and mechanical connection s and reassembling testing of the same after carrying out rewinding of motor of under mentioned capacity single/three 3ph 415 Volt, 50 Hz with supper enarnefled copper with having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified 0.5 HP to 2 HP complete all as directed by Engr-in-Charge.
M&L for rewinding of butnt motor front respective laundry/CHS machines by disconnecting all electrical and mechanical connection s and reassembling testing of the same after carrying out rewinding of motor of under mentioned capacity single/three 3ph 415 Volt, 50 Hz with supper enarnefled copper with having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified 2HP to 5 HP complete all as directed by Engr-in-Charge.
M&L for rewinding of butnt motor front respective laundry/CHS machines by disconnecting all electrical and mechanical connection s and reassembling testing of the same after carrying out rewinding of motor of under mentioned capacity single/three 3ph 415 Volt, 50 Hz with supper enarnefled copper with having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified 7.5 HP to 10 HP complete all as directed by Engr-in-Charge.
M&L for rewinding of butnt motor front respective laundry/CHS machines by disconnecting all electrical and mechanical connection s and reassembling testing of the same after carrying out rewinding of motor of under mentioned capacity single/three 3ph 415 Volt, 50 Hz with supper enarnefled copper with having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified 12.5 HP to 20 HP complete all as directed by Engr-in-Charge.
S&F in replacement of V Belt for washer Extractor of capacity -30 Kg, as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of electric operated drain valve as per existing sample/model suitable for washer Extractor of capacity 60 Kg, as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Main water inlet/drain butterfly valve of size 50 mm dia PN 10 along with actuator assembly with having metallic body with pneumatic operated complete as per existing sample/model suitable for washer Extractor of capacity-60 Kg as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of single solenoid valve for washer Extractor of capacity-60 Kg as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Door gasket for washer Extractor of capacity-60 Kg as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Hose pipe of dia 2" to 4" for washer Extractor of capacity-60 Kg as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of V Belt for for washer Extractor of capacity-60 Kg as per sample complete all as directed by Engr-in-Charge.
S&F in and including cleaning inside of chamber along with de carbanization of combustion chamber and servicing of all connected eqpt of primary and secondary both system complete all as directed of following of silicon oil seal with circlip & O ring for slucing machine of capacity -30 Kg, as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Flannel cloth for flat work ironer size 32"x13", as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Final cover for flat work ironer Size 32"x13", as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of main bearing Set for flat work ironer Size 32"x13", as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of main drive V belts for drying tumbler as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Automatic steam intl valve for drying tumbler as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of Contractor for drying tumbler as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of solenoid valve for vaccum ironing machine as per sample complete all as directed by Engr-in-Charge.
Supply, mixing and filling of more ethylene glycol concentrate alongwith the necessary additives and inhibitor in cognition, required for operation of plant and network. The mixing freezing temperature shall be minus 10 degree C all as specified and directed by Engr-in-Charge.
Supply and mixing Hydro caloric acid (HCL) concentrate complete all as directed by Engr-in-Charge.
S&F in replacement and including cleaning inside of chamber along with de carbonization of combustion chamber and servicing of all connected eqpt of primary and secondary both system complete all as directed of following under mentioned items for oil fired incinerator model PY-VS-75 as per sample all as directed by Engr-in-Charge
S&F Fuel filter element per sample complete all as directed by Engr-in-Charge.
S&F Thermo Couple K type per sample complete all as directed by Engr-in-Charge.
S&F Pressure gauge0-40 Kgs/Cm2-1/4" BSP per sample complete all as directed by Engr-in-Charge.
S&F Electrode front pair as per sample complete all as directed by Engr-in-Charge.
S&F in replacemnt of solenoid valve of incinerator as per sample complete all as directed by Engr-in-Charge.
S&F Electrode rear pair as per sample complete all as directed by Engr-in-Charge.
S&F Sequence controller as per sample complete all as directed by Engr-in-Charge.
S&F Oil seal for fuel pump as per sample complete all as directed by Engr-in-Charge.
S&F HT cable as per sample complete all as directed by Engr-in-Charge.
S&F Spider LO-70 (Rubber Bush) as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of maint steam inlet valve automatic for washer extractor 60 Kg as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of thermocouple for washer extractor 60 Kg as per sample complete all as directed by Engr-in-Charge.
Supply and mixing industrial salt in water for descaling for steam boiler 600 kg/hr as per sample complete all as directed by Engr-in-Charge.
S&F in replacement of touch screen HMI for washer extractor 60/30 kg as per site requirement as per sample complete all as directed by Engr-in-Charge.
Supply and mixing descaling compound for steam boiler 600 Kg/Hr per sample complete all as directed by Engr-in-Charge.
M&L for dismentaling /opening of old damage heavy duty MS pipe fitings from boilers of any shape/size and replacement with new as heavy duty MS pipe fiting as per site requirement including necessary threading, welding work, flange, gasket of any size with nit bolts complete all as directed by Engr-in-Charge.
M&L for opening of Primary and Secondry chamber of incinerator and replacement of all damage/burnt items after repair reassembling of plant, as per sample complete all as directed by Engr-in-Charge.
M&L for high temperature resistance painting of incinerator and laundry plant boilers complete with synthetic high tempreture enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc (M&L wire brushing and cleaning top surface complete all as directed by Engr-in-Charge)
M&L for dismantling/opening of laundry plant/ incinerator plant and including cleaning inside and out side of system body and chambers including tightening of all nut bolt washer and replacement of defected nut bolt and washer and rubber packing and removing all dust and sludge particles compete system, under mentioned items for loundery as per sample complete all as directed by Engr-in-Charge.
S&F Gland washer HTN008N for boiler complete all as directed by Engr-in-Charge.make :Aspee
S&F valve assembly HTB/VA for boiler complete all as directed by Engr-in-Charge. make :Aspee
S&F air release valve high pressure complete all as directed by Engr-in-Charge.Make: as per sample
S&F Butterfly valve high pressure 25 mm complete all as directed by Engr-in-Charge. Make: as per sample
S&F Butterfly valve high pressure 20 mm complete all as directed by Engr-in-Charge.Make: as per sample
S&F Blow down valve size 20 mm complete all as directed by Engr-in-Charge. Make: as per sample
S&F Y stainer size 15 mm dia bore complete all as directed by Engr-in-Charge. Make: as per sample
S&F gate valve 15mm complete all as directed by Engr-in-Charge.Make: as per sample
S&F PVC washer for valvegauge HTB/002 15mm complete all as directed by Engr-in-Charge.Make: Aspee
S&F V belt size A 55 complete all as directed by Engr-in-Charge.Make: as per sample
S&F Gas kit for laundry complete all as directed by Engr-in-Charge.Make: as per sample
S&F fuel filter complete all as directed by Engr-in-Charge.Make: as per sample
S&F fuel pipe complete all as directed by Engr-in-Charge.Make: as per sample
Top Mind Industries Pvt Limited
Electromech Engineers
M/S FAISAL TRADING CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .