Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.0 L+₹78,469.29 (10.9%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance higher Amount Quoted | |
| 3 | L3₹9.5 L+₹2.3 L (31.3%)Rejected-Finance | L3 | Rejected-Finance higher Amount Quoted |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
7 Oct 2019, 4:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIR OF UG AND OH LINE, TRANSFORMERS AND MISC WORK
2019_MES_282933_1
8491/E8/AGE I UDAIPUR
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA MOUNT ABU
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹19,000
Yes
8 Jan 2020
17 Sept 2019
9 Oct 2019
17 Sept 2019
7 Oct 2019
25 Sept 2019
18 Sept 2019 - 24 Sept 2019
Amount
Dismantling insulator, any size from LT poles and removing from site all as specified and directed.
Dismantling of cross arms of MS channel or angle section etc and removing from site or setting aside for reuse complete all as specified and directed.
Material & labour for PCC 1 : 3 : 6 type C-2 using 40mm grade stone aggregate for foundation of stay/pole/ strut as per specified and directed.
Material & labour for PCC 1 : 3 : 6 type C-1 using 20mm graded stone aggregate for pedestal including necessary from work including finishing to exposed surface even and smooth without using extra cement complete all as specified and directed. Note for item No 3 & 4 : Volume of pole/ strut embedded in concrete shall be deducted for the purpose of payment.
Supply & fix stay assembly comprising of stay bow galvanized 14mm dia x 400mm long, stay rod 16mm x 2.15 meter long with nuts, bolts, washer, mild steel galvanised stay plate of size 30cm x 30cm x 6mm thickness, two Nos thimble and clamps etc complete all as specified in electrical No 1 of SSR Part-I. Note : Loop type insulator, excavation & earth work and concrete foundation shall be measured and paid separately under respective of Sch 'A'
Material & labour for cross arms, bracing, supports, back plate & clamps fabricated from structural steel section including nuts, bolts, washer cuttings, welding bending cold or hot, drilling holes for bolts in any shape for bolts in any shape or size inclusive of painting with 2 coats of aluminum paint over a coat of primer complete all as specified and directed.
Material & labour for loop type insulator vitreous porcelain, white, brown or green Large size with overall dimension 90 x 140mm clearance of hole 16mm, 1100 Volts complete all as specified and directed.
Material & labour for pin type, porcelain vetreous white, brown or insulators incl one gaivanized MS spindle, two galcanized iron washers & one GI nut, 100mm height, 65mm dia, 1100 Volts grade complete all as specified and directed.
Material & labour for shackle type insulator, porcelain vetreous white, incl gaivanized MS strips washers & nuts working pressure 1100 Volts, 100mm high and 115mm dia complete all as specified and directed.
Dismantling and carefully taking down and Material & labour for galvanized steel stranded stay wire of any size for stay of poles including necessary clamps of 50 x 6mm FI and bolts nuts of suitable size complete all as specified and directed.
Dismantling of existing cable andSupply & Fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm e nominal cross section 2 core in service connections.
Supply install and commissioning and testing LT Panel KIOSK type outdoor platform mounting factory made totally enclosed dust and vermin proof (proctection IP-54) the LT panel made of CRCA sheet 2 mm thck with MS angle section 50 x 50 x 6 mm properly fabricted painting wit powder coated finishing the panel board shall be suitable for 433 V, 50 Hz, 3 phase, 4 wire system and complete with coppe bus bar 250 amps in bus bar chamber bus bar mounted on proper insulator internal wiring with suitable multistranded copper conductor cables lugs and cable galnds for incoming and outgoing cables etx all as specified consisting of followings :-
(A) INCOMING (a) MCCB 200 Amps, 4 pole, 433 V, 3 Phase, 50 Hz 36 KA fixed manual type with thermal magnetic release for overload and short circuit protection- 01 Nos. Make : ABB/CROMPTON GREAVES/L&T/SIEMENS?SCHNEIDER (b) Digital voltmeter 0-500 V 01 No (c) Digital Ampmerer 0-200 V with CT - 01 No (d) Panel mounting indicating Neon lamp R-Y-B (Set of 3) 01 set (B) OUTGOING (a) MCCB 160 Amps, 4 pole, 433 V, 3 phase, 50 Hz, 36 KA fixed manual type with thermal magnetic release for overload and short circuit protection - 01 Nos. Make : ABB/CROMPTONGREAVES/L&T/ SIEMENS/ SCHNEIDER
Dismantling and carefully taking down and Material & labour for 8 SWG (4mm dia/or nearest) mild steel, galvanized wire laid for earth continuation main guarding wire with cardle including straining properly and binding with steel winding complete all as specified and directed.
Stringing and tightening only aluminium conductor steel reinforced (ACSR) any size, straining properly on insulators and binding with aluminium binding wire on the existing HT/LT poles complete all as specified and directed.
Supply & Fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 120 sqmm
Matrial & labour for repair of GO to smooth operation & alighment of contacts, connect/tighting of HT cable including greasing of moving mechanism, replacement of Male contact/moving contact blade, female contact/fix contact jaw, tinned copper flexible jumper, MS jumper carrier, back connector plate where required and replacement of handle/lever, nut-bolts washers etc. of required size and length and testing all as specified and directed by Engr-in-charge.
Excavating in trenches n.exc 1.50mtr wide and n.exc 1.5mtr in depth for foundation/ pipes/ cables etc, n.exc 10sqm on plan and n.exc 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in soil complete all as specified and directed.
Removing of excavated surplus soils, n.exc 50mtr and depositing where directed at a level n.exc 1.50mtr above the starting point complete all as specified and directed.
Material & labour for sand cushioning for PVC cable with screened and washed sand and punning to provided a required covers all as specified and directed.
Material & labour for brick protection cover to LT under ground cable with old size sub class 'B' bricks laid dry width equal to length of brick abouting each other with gaps between adjacent brick not exc 10mm al1 as specified and directed.
Material & Labour for cutting of tree-branches touching HT/LT OH lines having girth exc 30cm and n.exc 100cm and disposal of the branches to a distance n.exc 50mtr and clearing the site all as specified and as directed.
Material & Labour Painting of old surface and applying two coats of aluminiuim paint over a coat of zinc chrome primer to existing MS channel, clamps, etc on existing any type of poles of 9/11 mtr all as specified and directed.
Material & Labour Painting of old surface and applying two coats of black and white as Zebra crossing, white painting of pedestal etc on existing RCC poles of 9/11 mtr all as specified and directed.
De-Hydration and filtration of transformer oil of the transformer, and Voltage stablizer, AC, 11KV/433 Volts mounting on 2 pole/4 pole structure/platform from all as specified and directed by Engineer- in- charge.
Topping the transformer with new transformer oil of dielectric strength more than 50 KV, mounting on 2/4 pole structure/plate from all specified & directed by Engineer-in-charge.
Painting of Transformer 11/0.433 KV form painting out side with two coats of synthetic enamel grey paint after scraping old painted surfaces complete all as specified and directed of 315 KVA capacities :-
Replacement of sillica gel for transformer of capacity 63/ 250/ 315 KVA complete all as specified & directed.
Supply and fix in repair asbestos rope for exhaust pipe of DG Set complete all as specified and directed.
Repair to DG Set 15-25 KVA with prime mover water cooled engine 4 stroke vertical dismantling of head assy and carrying out over hauling of the engine by repair and replacement of the following parts :- (a) Repalcement of fuel filter element - 01 No (b) Repalcement of oil & oil filter (c) Repair to engine panel wiring by replacement of wire looms, indicator lamp etc. (d) Replacement of tappet cover gasket - 01 set (e) Tightening of head stud nuts - 01 set (f) painting of complete DG set after cleaning and testing after repair as directed by Engr-in-Charge.
Supply & Fixing in repair of following items in existing LT panel boards and testing of complete panel after repair all as specified and directed.
Phase indicating lamp neon type complete with contact block & holder assembly RYB
Volt meter for 3 phase supply 0-500
Ameter for 3 phase load range 0-400
Supply & Fixing MCCB, 415 Volts, 3 Phase,with necessary modifications in Panel Board for connection of MCCBs complete all as directed including connecting and testing of the following capacity :-
160 Amps, 36 KA breaking Capacity,4 Pole, 50 Hz, 415 Volts, Make : ABB
100 Amps, 16 KA breaking Capacity,4 Pole, 50 Hz, 415 Volts, Make : ABB
63 Amps, 16 KA breaking Capacity,4 Pole, 50 Hz, 415 Volts, Make : ABB
Material & Labour spray painting the existing LT panel boards outdoor type of any size with two coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. The panel door shall be painted internally and externally both and remaining portion of the panel shall be painted externally only.
Material & Labour for repair of LT panel inner/outer doors by replacing of door hinges, handle, locking arrangement & misc work for smooth operation of panels doors.
Disconnecting and taking out carefully existing defective copper cables from panel boards and Supply, fixing & testing PVC insulated multi stranded copper conductor heavy duty 1100 Volts grade single core LT cable of size 16 Sqmm for connection between bus bar and main switch of LT panel board or alternator to panel board including providing solderless copper thimbles complete all as directed.
Material & Labour Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size.
Material & Labour Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size.
Supply & laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm 3 core
Taking down and supply & fixing of 12V, 80AH battery suitable for DG Set. Make-EXIDE/AMRON/LUMINUS
M/S Balkishan Panwar Construction
boon construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .