Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.2 L+₹3.0 L (14.6%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.2 L+₹4.0 L (19.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹24.8 L+₹4.6 L (22.8%)Rejected-AOC HARI OM BHAWAN CIRCULAR ROAD UPPER KAITHU SHIMLA | L4 | Rejected-AOC L4 | |
| 5 | L5₹25.1 L+₹4.9 L (24.1%)Rejected-AOC C O SH JITENDER CHAUHAN 542 L MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | L5 | Rejected-AOC L5 |
Tender Value
₹29.9 L
EMD Value
₹52,400
Closing Date
25 Jul 2019, 5:00 pmClosed
XEX Electrical division No. 1 shimla
Executive Engineer Electrical Division No-1 HPPWD Shimla-9
SH Providing Addressable Fire Alarm Public Address System therein
2019_PWD_29825_1
Electrical Div. No-1 PWD Shimla 19-20- 478-83 dt.
Open Tender
Electrical Works
Item Rate
365 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,500
E.E.Electrical Division No-I Shimla-9
₹52,400
7 May 2020
2 Jul 2019
26 Jul 2019
2 Jul 2019
25 Jul 2019
2 Jul 2019
Amount
Supply, Installation, Testing and Commissioning of 2 loop addressable fire alarm control panel. Each Detection Loop of FACP shall accommodate up to 250 detectors and devices in any combination. FACP shall accommodate up to 2500 detectors and devices at 100% capacity in any combination and shall support up to 30 loops, 10,000 history events, menu driven user interface with smart search. FACP shall have a supervised electronic provision to store site-related back-up of Auto-CAD As-Built Drawings, Configuration Software Back-Up, Reports, Logs, 4 GB memory card in FACP. The Panel shall be VDS/EN 54/UL approved. Makes:Bosch/ Honeywell(Notifier) /Siemens(FireFinder) /TYCO(Simplex) /Johnson Control
Supply, Installation, Testing and Commissioning of Intelligent Addressable Double Action Indoor Application Manual Pull Stations / Manual Call Points suitable for wall/column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0°C to 50°C and humidity tolerance range up to 93% RH, Non-Condensing. MCP shall be VDS/ EN 54/ UL approved. Makes: Bosch/ Honeywell(Notifier)/ Siemens(FireFinder)/ TYCO(Simplex)/ Johnson Control
Supply, Installation, Testing and Commissioning of Standalone Loop Powered/NAC based sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should be programmed from the panel. Shall be EN54 / Vds/ UL Certification. Makes: Bosch/ Honeywell(Notifier)/ Siemens(FireFinder)/ TYCO(Simplex)/ Johnson Control
Supply, Installation, Testing and Commissioning of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module to trigger 3rd party utilities like AHU shut-off, Pressurization fan activation, Special notification activation etc. The contact shall be rated for 2A@24Vdc (Resistive) & 1A@24Vdc (Inductive). The control module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 93% RH, Non-Condensing. shall be VDS/ EN 54/ UL approved. Makes: Bosch/ Honeywell(Notifier)/ Siemens(FireFinder)/ TYCO(Simplex)/ Johnson Control
Supply, Installation, Testing & commissioning of Response Indicator including making connections. Make : Custom
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make: Custom
Supply and erection of 1.5 sqmm PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Make: Polycab/ Havell's/ KEI
Supply, Installation, Testing & commissioning of Horn Loudspeaker made with ABS, water and dust protected to IP 65, Sound pressure level at 15W/1W - 115/103 dB (SPL), Effective frequency range 500 Hz to 5 kHz, Rated power 15W. Make: Bosch/ JBL/ Tannoy
Supply, Installation, Testing & commissioning of Wall Mount Speaker with operation 6 Watts. Make Bosch/ JBL/ Honeywell/ Tannoy/ Jhonson Control
Supply, Installation, Testing & commissioning of 480W Booster amplifier. Make Bosch/ JBL/Tannoy/ Honeywell/ Jhonson Control
Supply, Installation, Testing & commissioning of 3KVA UPS on line, Double conversion, Microprocessor controlled, With LCD, Input Voltage: 230V Freq : 40-70HZ P.F. 0.95 Output: 220Volt ± 2% Freq: 50HZ ± 0.05HZ, P.F. 0.8 With SMF Batteries for 60 min backup on full load. Make: APC, Libert, Emerson, Numeric
Supply, installation, testing and commissioning of 2 core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc. Make: Finolex/Polycab/Havell's/KEI
Supply and erection of PVC pipe 25mm dia ISI marked (Medium) recessed in wall / ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: BEC, AKG, Kalinga / Diplast
Supply, installation, testing and commissioning of 22 U Standard rack to place all equipment. Make: Valrack, Comrack, HCL
NOTE: As there are so many variant for one product as different manufacturers using their monopolized terminology and codes for their product, It is impractical to compare each and every feature of various manufacturers. So the general specifications with Max ± 5% deviation in parameters (in respect of the preferred makes) will be treated AT PAR specification with the tender document and will be allowable provided that it may not effect the performance of the system.
TARUN FIRE SYSTEM
APEX FIRE GUARD ENGINEERS
KHARBANDA ELECTRICALS
Bitureks Infra Pvt. Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .