| 1 | L1₹46.8 LAccepted-AOC GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹51.9 L+₹2.9 L (5.84%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Oct 2024, 6:00 pmClosed
Major MK Yadav, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIRS/ MAINTENANCE OF DG SETS, AMF PANELS, JUNCTION BOX, PERIMETER LIGHT, POLE PAINTING, HIGH MAST, EXTERNAL LIGHTING AND ALLIED WORKS IN DOMESTIC AREA, TECHNICAL AREA AND DDK RANGE AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2024_MES_670567_1
C/8038/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹90,000
Yes
4 Dec 2024
3 Sept 2024
8 Oct 2024
3 Sept 2024
7 Oct 2024
18 Sept 2024
Amount
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material all as specified and directed. (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4 core 16 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)
Supply and laying fly ash bricks best quality, laid in trenches, perpandicular to U/G cable for cable protection complete all as specified.
Laying only old bricks obtained from item No 02 perpandicular to U/G cable for cable protection complete all as specified.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
M & L for Boring of horizontal hole under road, pavement, hardstanding by any means suitable for passing through up to 50 mm bore, complete all as specified. Note : (i) One run of boring of horizontal hole will be measured as one unit length. (ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account. (iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.
M&L for cement concrete ( 1:3:6) type C-2 using 40mm graded crushed stone aggregate as in pole foundation, filling and mass concrete complete all as specified
M&L for cement concrete ( 1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping of pole including weathering, slightly rounded or chamfered angles and throating, necessary formwork as directed complete all as specified
M&L for Street Light Fittings Bracket, fabricated from GI Pipe 32mm Bore (dia), Light Grade, 1.60 METRE long, bend to required shape and fixing with and including Mild Steel Flat Iron Clamps 40X5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc., to Pole, applying Painting with One Coat of Red Oxide Zinc Chrome Primer and over Two Coats of Aluminium Paint to Mild Steel Works including Taking down old unserviceable Street Light Fittings Bracket, complete all as specified and as directed.
Excavating in trenches/over areas n.exc 1.5 m depth near junction box/ feeder pillar box, disconnecting & taking out cable, cutting burntout uninsulated portion of cable and rectify the defect and relaying the same in trenches, filling sand around the cable with retrieved sand ( approved quality coarse sand for sand cushioning, if required, is deem to be included in the quoted rates) spreading and punning down to 18 cm thickness. cover with retrieved bricks and returning and filling the excavated soil and connecting the cables with bus bars including provision of lugs as applicable and testing complete all as specified.
Supply and fixing loop in- loop out fuse junction box of internal dimention 250 x 200 x 100mm made of FRP sheet with weather proof canopy and locking screw fitted with and including 50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including taking down old unserviceable junction box all as specified and as directed by Engr-in-Charge. Note : Cost of lugs and PVC gland of suitable size if required on site for connecting cable in junction box is deem to be included in the quoted rates.
Material & labour for Flexible PVC insulated multicore FR PVC sheathed multistranded copper conductor cable of size 2.5 Sqmm x 3 core for voltage grade up to 1100 V conforming to IS 694 : 2010 for connection of light fitting from junction box or from over head conductors to fitting incl taking out old unsv cable complete all as specified and as directed by Engineer-in-Charge.
Material & labour for Flexible PVC insulated multicore FR PVC sheathed multistranded copper conductor cable of size 1.5 Sqmm x 3 core for voltage grade up to 1100 V conforming to IS 694 : 2010 for connection of light fitting from junction box or from over head conductors to fitting incl taking out old unsv cable complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix in repairs, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, type MNX 40 rating, 40 Amps, incl taking down old unsv complete all as specified and directed.
Supply and fixed in repair of multifunction digital timer switch (5-40) Amps , 240 Volts , AC , Single phase incl taking down old unsv complete all as specified and as directed
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs incl taking out old unsv MCB complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply installation, testing and commissioning of outdoor street light panels, degree of protection IP 54, three phase, maximum load 12 kW, prewired with Digital timer switch,contactor TP rating 65 Amp and MCB Tripple pole & neutral rating 63 Amp,incl taking down old unsv complete all as specified and directed.
S & F Non metallic PVC medium grade conduit 20 mm dia, ISI marked for drawing aluminium/ copper conductor cable between pole junction box and light fitting including fixing clamp made of GI strips and nut and bolts (Minimum 3 clamp in each pole to be provided.) including taking out old unserviceable complete all as specified and directed.
M & L Painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/ for street light with two coat of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter ( Example - P- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed.
M & L for Tree trimming around 5 mtr around existing overhead line, removing of vegitation and bushes between one span (2.5 Mtr both side , distance between span pole to pole max 25-50 mtrs to be consider as one span) complete all as specified and directed by Enginner-In-Charge. Note:- (i) Contractor has to trim and pruning of tree to be done falls in span between pole to pole. (ii) Necessary survey of site to be done before quoting the rate. If required JCB to be used for clearing the vegitation on the rout of overhead line. (iii) Due to speedy growth of trees/ branches pruning / trimming to be done in perodicity as required irrespective of location. Location can be repeated as per the requirement and measured as per work done. (iii) After tree pruning disposal of branches and kept in stack at the site (within 100 mtrs) as directed by Eng in charge shall be done by the contractor.
Taking down old and Supply & fixing in replacement of LED 25 W Post Top Lantern, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with IP66 protection high power LED as light source by using 2 core PVC insulated cable aluminium conductor 2.5 Sqmm approx 2 m length complete all as specified and directed.
Taking down and disconnecting Old unsv solar street light and Supply and fixing all in one Solar street light made with High Efficiency Mono Crystalline Solar PV Module 75 Wp under STC, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, W-LED with minimum 135 lumens per watt and UV free ,MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, which increases the backup time with system wattage 20 watt, 12 Volt, DC system lumen output greater than 2970 lumen, system panel module capacity 12 V, MPPT charge controller and PR Sensor with CCT 6000-6500K incl polycrysttaline cell, IP-65 with efficiency greater than 90% with adjustable tilt angle 0-15 degree complete all as specified and directed as per Engr-in-charge.
Supply & fixing in repair LED street light 60 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000 protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen.
Supply & fixing in repair LED flood light 100 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 10000 protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen.
Supply & fixing in repair LED flood light 200 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 10000 protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen.
Supply and fix of LED Aviation Obstruction light (Red Colour) incl taking out old u/s fitting completeall as specified
Taking down carefully diesel engine driven generating set capacity 400KVA after decoupling alternator, dismantling parts of diesel engine for top overhauling & inspection of rocker level bush, cylinder head valve, valve seat, oil chamber gasket, piston ring, cylinder liner, connecting rod, bearing, connecting rod brush, handling conveyance of defective cylinder head to nearest workshop for decarbonising, valve grinding, polishing, seat cutting & fitting, re-assembling of parts including replacement of engine oil as per exterior grade/specification and unserviceable parts, miscellaneous parts such as nuts, bolts, washers, screws, circlip, benjo bolt, copper washers etc. and re-fixing engine assembly in original position and testing for smooth operation with and including Overhauling/calibration of fuel injection pump including replacement of service kit, bearing, spring washers, copper washers, benjo bolt, gasket ,calibration of injectors including replacement of nozzles , Repairs to radiator assembly of diesel driven generating set engines by proper cleaning of the storage tanks, circulatory tubing’s and fins with caustic soda solution, breezing leaking points of circulatory tube & soldering leaking points of circulatory tube and storage tanks including testing for water tightness complete all as specified and directed. Make of DG Set:: Greaves
All as per above item No. 31.00 here in before but 320 KVA DG set complete all as specified and as directed.
All as per above item No. 31.00 here in before but 200 KVA DG set complete all as specified and as directed.
NOTES:- (Applicable for BOQ Serial Item No. 31.00 to 33.00 here in before) (i) The work shall be carried out through authorised Service Engineer of OEM or OEM Certified agencies or agencies as approved by GE.
Notes Contd....(ii) Cost of minor items like teflon tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (iii) Spares required for replacement of defective ones will be measured and paid seperately under respective item as supply only here- in -after. The parts which are not listed in the BOQ, shall be measured and paid as Supply only undrer PC Sum. Replacement of parts shall be as per recommendation of service center.
Supply only the following spare parts for DG set of capacity 400 KVA
Greaves Lub oil C14-20 Ltr pack
Greaves Lub oil C14-20 Ltr pack
Lub oil filter
Element pre fuel filter
Element micro fuel filter
O-rings(SPRS)
Outer Element
Inner Element
A V Mount-AVD/1515A
D4 Flex pipe set
Set of Hoses-TBD3V12 RC
Set of Hoses clips TBD3V12
Set Sealing ring TBD4V12
CU Washer
Gasket- cylinder cover
Gasket Air intake mani
Gasket intake manifold
O ring NBR 20x3
Plunger barrel assy D4V12 China
Delivery valve D4V12 China
Paper Insert oil Centrfug
FIP repair kit
Fuel Flexible pipe 20'
Coolant Additive 10 Ltr Pack
Fuel pre filter KF 5.0 Ltr
M S washer 20 x 4.6 sealing
5 Hole Nozzle 234
Supply only the following spare parts for DG set of capacity 320 KVA
Camshaft
Piston ring set (115DIA )
Liner
Assembly Lub Pump
Push Rod
M.S Washer 20 x 4.6 Sealing
AdJ screw M10 x 1.5 x 39 LG
Valve bridge
Rocker Lever Assembly
Suction Strainer V12
Delivery Pipe
Pipe (Oil supply to centrifugal )
Motorpal repair kit2 Mpactuator
Spinon assembly kit
Repair kit
Set of Gasket 12V14TAG RC
Copper washer
Copper washer 1.0 mm
Copper washer M8x11.5x1.0 THK
Set of hoses 12V14TAG RC
Lub Oil Filter 234
Element pre fuel filter
Element Micro fuel filter
Radiator pre-mix greaves kool 10 Ltr
Hex nut M8 DIN 934
Hex nut M10 DIN 934M-10
Washer M8x17x1.6
Plain washer A10.5 (M10)
Hexscrew M8x1.25x25 CL8.8
Hexbolt M10x1.5x90 8.8/ CL
T bolt clamp TB114
T bolt clamp TB115
T bolt clamp TB94
ALN Screw M8x30 912 12.9
O ring Lop pipe to crankcase
Gasket for strainer
HE( CBOLT-M10X90 10.9/CL
Three bond
Red gasket maker
Sand paper
Old cloth
Locktite 242
Supply only the following spare parts for DG set of capacity 200 KVA
Greaves Lub oil C14-20 Ltr pack
Lub oil filter
Element pre fuel filter
Element Micro fuel filter
Radiator pre-mix greaves kool 10 ltr
Gasket for PDC rocker cover
Element to air filter
EMS936-Engine controller
CU-washer (604920100610)
Copper washer (604920101418)
Leak off pipe (S/F5000 FIP)
Electrical wiring and automation work
Cleaning of radiator as per OEM checklist .
Supply and fix in repair Air filter of capacity upto 400 KVA DG Set as per OEM specification complete all as specified and as directed by Engineer-in-charge .Make : Cummins/Ashok Leyland/Geaves /Kirloskar.
Supply and fix in repair Fuel filter of capacity upto 400 KVA DG Set as per OEM specification complete all as specified and as directed by Engineer-in-charge .Make : Cummins/Ashok Leyland/Greaves /Kirloskar.
Supply and fixing in repair aluminium radiator assembly capacity from 250 KVA to 400 KVA DG set of any make as per existing model and complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair aluminium radiator assembly capacity from 100 KVA to 200 KVA KVA DG set of any make as per existing model and complete all as specified and directed by Engr-in-Charge.
Supply only Fuel Flexible pipe size 15mm bore (length upto 20 Foot) embedded in flexible metal wire having one side nut & one side banjo or both side nut or both side benjo nut as per existing suitable for DG Set of capacity 20 KVA to 200 KVA of any make : Cummins/Ashok Leyland/Mahindra/Kirloskar.
Supply only Fuel Flexible pipe size 15mm bore embedded in flexible metal wire having one side nut & one side banjo or both side nut or both side benjo nut as per existing suitable for DG Set of capacity 250 KVA to 400 KVA of any make : Cummins/Ashok Leyland/Mahindra/Kirloskar.
Supply only Hose pipe set with clamp, nut & bolt complete, suitable for DG Set of capacity 20 KVA to 200 KVA of existing make complete all as specified and directed
Supply only Hose pipe set with clamp, nut & bolt complete, suitable for DG Set of capacity 250 KVA to 400 KVA of existing make complete all as specified and directed
Supply only V Belt / Fan belt as per existing suitable for DG Set of capacity 20 KVA to 200 KVA of any of Make:- Cummins/Ashok Leyland/Mahindra/Kirloskar.
Supply only V Belt / Fan belt as per existing suitable for DG Set of capacity 250 KVA to 400 KVA of any of Make:- Cummins/Ashok Leyland/Mahindra/Kirloskar.
S & F for cleaning of the fuel tank by drain the fuel and remove the dust/sludges etc and refill the fuel complete all as specified and directed by Engr-in-Charge.
S & F in repair of self starter assembly of existing Make for 20 to 63 KVA DG set complete all as specified and directed by Engr-in-Charge.
As per above item No 51.00 here-in-before but upto 82.5 to 160 KVA DG set.
As per above item No 51.00 here-in-before but upto 200 to 320 KVA DG set.
As per above item No 51.00 here-in-before but 400 KVA DG set.
S & F for Replacement of Voltage regulator Device (AVR) for the DG set of capacity 20 to 100 KVA of any make and as per existing including taking down old u/s complete all as specified and directed.
As per above item No 55.00 here in before but upto 125 to 250 KVA DG set.
As per above item No 55.00 here in before but upto 320 to 400 KVA DG set.
S & F in repair 150AH,12 Volt lead acid battery complete all as specified and directed by Engr-in-Charge. Make: Exide or equivalent.
S & F in repair 180AH,12 Volt lead acid battery including taking down old u/s complete all as specified and directed by Engr-in-Charge. Make: Exide or equivalent.
Supply Water Pump complete assembly including complete assembly , Pulley, Spin on filter, BT unit, Gasket, Bearing,Hose pipe, rubber seal & clamp capacity 20 to 200 KVA DG set of any make complete including taking down old unserceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.
Supply Water Pump complete assembly including complete assembly , Pulley, Spin on filter, BT unit, Gasket, Bearing,Hose pipe, rubber seal & clamp capacity 250 to 400 KVA DG set of any make complete including taking down old unserceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.
S & F in repair of solenoid switch of existing Make for 40 to 125 KVA DG set including taking down old u/s complete all as specified and directed by Engr-in-Charge.
As per above item No 62.00 here in before but upto 200 to 400 KVA DG set.
Decoupling alternator from the DG set engine, transportation to nearest workshop for repair, dismantling parts of alternator i.e. stator, rotor, slip ring, MX unit/AVR, carbon brass with holder for rewinding of armature with suitable size of super enamelled copper wire including heating varnishing providing required insulating materials for alternator capacity 200 to 400 KVA as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Decoupling alternator from the DG set engine, transportation to nearest workshop for repair, dismantling parts of alternator i.e. stator, rotor, slip ring, MX unit/AVR, carbon brass with holder for rewinding of armature with suitable size of super enamelled copper wire including heating varnishing providing required insulating materials for alternator capacity 20 to 125 KVA as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply and filling in replacement of Engine oil 20W40 to top up/ refilling of all DG set as per the direction of Engineer-in-charge.(Make Gulf/Castrol/Volvalin)
Supply and pouring distilled water for battery and as directed .
Supply for pouring of coolant ( Premix & Raw coolant ) pre-mix greaves kool suitable for radiator for Kirloskar/Jackson make engine as per the requirement of time to time as directed by Engr-in-charge for various capacities of DG Set (Make : SERVO/CASTROL/PUROCOOL)
Material and labour for repairing to AMF/ATS Panel and rewiring of the defective wiring connection of AMF panel by proper connection using thimble for 20 KVA to 200 KVA DG set at various location , by taking shut down from Main Power House , including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed : Note : (i) Servicing and commissioning of DG set AMF /ATS panel to be carried out as per manufacturers instructions and by qualified service engineer of DG set service center. (ii) Materials/Spare parts required for above service maintenance shall be measured and paid seperately under repective items as "Supply only Materials". (iii) Minor spares like Lugs, ferrule etc, provided by contractor.
Material and labour for repairing to AMF/ATS Panel and rewiring of the defective wiring connection of AMF panel by proper connection using thimble for 250 KVA to 400 KVA DG set at various location , by taking shut down from Main Power House , including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed : Note : (i) Servicing and commissioning of DG set AMF /ATS panel to be carried out as per manufacturers instructions and by qualified service engineer of DG set service center. (ii) Materials/Spare parts required for above service maintenance shall be measured and paid seperately under repective items as "Supply only Materials". (iii) Minor spares like Lugs, ferrule etc, provided by contractor.
Supply only Digital Amp / Volt / Frequency meter of range 0-30 Amp as per existing type any make including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only Digital Amp Meter for above 30 Amp as per existing type of any make (As per sample) including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only push switch Start, Stop & Reset including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only Start & Stop Relay 30Amps,12 Volt including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only phase Indicator lamp of R-Y-B Phase including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only Oil level indicator meter including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply and fix in repair Oil pressure sensor upto capacity 400 KVA incl wiring with suitable size complete all as specified and directed by Engineer-in-charge . Make- Kirloskar or Equivalent
Supply only 20 A HRC fuse including fuse holder including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only upto 63 A HRC fuse including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only up to 160A HRC fuse including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only upto 225A HRC fuse including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only Air break power contactor, 240 volt, AC-I 40 amps, including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only power contactor AC 1 And AC 3, 4 pole 150 to 800 Amps for suitable existing panel complete including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply only 63 A 4- pole contactor including replacement of defective accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed . make: L&T, Model MCX 12 or Equivalent
Supply Only AMF Controller unit as per OEM specification for the DG Set of capacity upto 125 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply Only AMF Controller unit as per OEM specification for the DG Set of capacity from 160 KVA upto 250 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Supply Only AMF Controller unit as per OEM specification for the DG Set of capacity from 250 KVA to 400 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed
Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents. (a) Provide a prime cost of Rs.3,50,000.00 for supply only of spare parts suitable for various capacities of DG Sets, AMF Panel including all spare parts and Rewinding of Electric Motors/Alternators after dismantling and based on findings of the actual requirements of spares/burnt out windings for rewinding, through a BOO convened by the Accepting Officer.The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE. Rewinding of electric motors/alternators/dynamos/self starter shall be done through authorised Service Engineer of OEM or OEM Certified Agencies as approved by GE. (b) Bidder's/Contractor's quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidder's/Contractor's is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidder's/Contractor's quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum.
I.S.ENTERPRISE (BID ID -3110069)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .