SE-ES
SUPERINTENDING ENGINEER/ ELECTRICAL SYSTEM, NCTPS-I, CHENNAI-120
NCTPS I ES Circle MRT Dn S Dn I Annual overhaul works Unit I for the year 2020-21
2020_EB_184157_1
SE ES NCTPS I WC No 77 2020 21
Open Tender
Power/Energy Projects/Products
Works
15 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2,500
Yes
1 Dec 2020
4 Nov 2020
19 Nov 2020
4 Nov 2020
18 Nov 2020
4 Nov 2020
90 days
Amount
Digital Excitation system Cleaning of converter cubicles, Field breaker cubicles, and Regulations cubicle checking the tightness of AC/DC bus bars joints, terminal blocks in converter panels, Field breaker panel and Regulation panel.
Generator Relay panel Testing & GCDP Panel Meter Calibration: Charges for transporting the testing equipment, Cleaning & assisting for conducting the test on Generator Relay Panel testing.
Cleaning, Tightness checking, defect replacing and testing assistant for calibration of panel meters and transducers at UCB.
Valve Actuator Charges for cleaning disconnection of control cables, terminal tightness checking of actuator terminal blocks, local push button and lubricating the limit switch mechanism as instructed by the maintenance Engineer incharge.
Charges for reconnection of control cables, setting of open/ close Limit/torque switches, testing of modules, motors and checking of operation as instructed by the maintenance Engineer incharge.
Charges for replacement of limit switch assembly and actuator terminal blocks as instructed by the maintenance Engineer in charge.
Charges for removing defective limit mechanism assembly, reconditioning & repairing the defective limit mechanism, Gear, Assembly & micro switch arrangement, Re-fixing, limit setting and checking the operation of 1 No Actuator assembly during routine / overhaul maintenance as instructed by the maintenance Engineer incharge.
Soot Blowers Checking the control circuit of WWSB’s /LRSB’s APH’s soot blowers modules for the healthiness & identifying the defective components as instructed by the maintenance Engineer incharge.
Synchronising Activities Charges for transporting of test equipments and for assisting Light up and Pre/Post Synchronising activities like Field Breaker, GT Breaker, UAT incomer Breakers, Close permissive and troubleshooting as instructed by our maintenance Engineer incharge.
HT panel relay retrofitting works Dismantling of existing relay control cables, CT & PT cables from terminal block to existing relay and releasing of static relays from panels.
Arrangement for Relay fixing works that is panel cutting and drilling for suitable cut-out in the existing panel.
Fixing of New Numerical relays Re-ferruling and re-laying and dressing of control cables and CT-PT cables from Terminal block to New Numerical relays.
Arrangements for fixing dummy plates in the dismantled relays cut out.
S.MATHURAM CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .