| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹24.0 L+₹2.2 L (9.93%)Rejected-Finance | L2 | Rejected-Finance High | |
| 3 | L3₹24.1 L+₹2.3 L (10.5%)Rejected-Finance | L3 | Rejected-Finance High | |
| 4 | L4₹24.4 L+₹2.6 L (11.7%)Rejected-Finance | L4 | Rejected-Finance High | |
| 5 | L5₹25.0 L+₹3.2 L (14.4%)Rejected-Finance | L5 | Rejected-Finance High |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
28 Aug 2021, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Provn of covered patients waiting shed for proposed accident and emergency care of MH, constr of simulator room at Tibri Mil Stn under GE Gurdaspur.
2021_MES_461221_1
GE GSR-39/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹44,000
17 Nov 2021
19 Jul 2021
30 Aug 2021
19 Jul 2021
28 Aug 2021
3 Aug 2021
Amount
M&L for Excavating in post holes( or similar holes) in soft/loose soil each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth of broken rubble mixed with earth around , in layers not exceeding 25 cm, watring, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed.
M&L for cement concrete type C2 1:3:6 ( 40 mm graded aggregates) as in foundation filling and mass concrete complete all as specified and directed.
S&F mild steel Gde Fe-410-W (Gde E-250 quality A) as in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces , cleats etc.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M&L for preparation of untreated steel/iron surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coats of sythetic enamel paint over and incl one coat of red oxide primer complete all as specified and directed.
Material and labour for providing and fixing gypsum board 12.mm thick on ceiling fixed with screws as per manufacturer instructions incl (i) Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre (ii).Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for 75mm thick Cement concrete typeC-2 , 1:3:6 (using 40 mm graded aggregate) as in floor /plinth protection
M&L for 40mm thick cement concrete type B-0 , 1:2:4 (using 12.5 mm graded aggregate) as in floor in unfair to receive tiles etc
S&F non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating complete all as specified and directed
M&L Brick work with sub class "B" bricks, straight or curved on plan exc 6 m mean radius , built in CM 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finishing even and smooth without using extra cement complete all as specified and directed.
All as per Srl item No 13 above but in CM 1:6.
M&L for prepration of newly plastered/un plastered of walls and applying two coats of cement base paint of shade as approved over a coat of cement primer complete all as specified and directed.
M&L for applying two coats of oil bound distemper above a coat of primer incl preperation of newly plastered of walls complete all as specified and directed.
M&L 2mm thick wall care putty on surfaces of wall complete all as specified complete all as specified and directed.
M&L for applying two coats of oil bound distemper above incl preperation of newly plastered of ceiling complete all as specified and directed.
S&F powder coated aluminium frame for doors ,windows, ventilators with one or more rebates including joining cleats for fixing complete all as specified and directed by Engineer-In-Charge.( Min. thickness of powder coating 50 micron) complete all as specified and directed.
Supply and fixing aluminium powder coated shutter (for doors) wighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber beading with neoprene packing anodized handle 2 no in each, locking arrangement(mortised) and aluminuium anodised tower bolt 200 mm long aluminium snap beading screws complete all as specified and directed.
S&F 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in aluminium door as per specification and drawing
S&F Sheet glass, 5.5mm thick ordinary quality, in squares, exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and incl solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed
S&F door closer hydraulically regulated, (Alminium die cast body) designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foun-dation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F 110mm bore PVC(SWR) pipes single socketed in any length laid in trenches or in floor complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius With access door complete all as specified and directed.
Surface excavation in soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes,pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft loose soil.
Returning, filling in, including spreading, levelling , watering and well ramming in layers not exc 25 cm.in soft/loose soil
Removing excavated soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L cement concrete type D-2, 1:4:8 using 40mm graded agregate as in foundations, filling and mass concrete
M & L for RCC type B-1, 1:2:4 (20 mm graded agrregate stones) as in foundation , including rafts, footings , foundation beams , plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in columns pillars post struts etc complete all as specified.
M & L for RCC type B-1, 1:2:4 (20 mm graded agrregate stones) as in beams, cantilever bressummers lintel over 1.50m spanas complete all as specified and directed.
M & L for RCC typeB-1, 1:2:4 (20 mm graded agrregate stones) in slab as in supported on walls , beams and columns in floors , roofs landing balconis etc complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or scouring with clips complete all as specified and directed.
S&F Mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or scouring with clips complete all as specified and directed.
S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers, and binders cut to length, bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or scouring with clips complete all as specified and directed.
M & L for form work to rough finished flat surfaces of sides of concrete foundations, footings, bases of columns , raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
M & L for form work to rough finished flat surfaces of sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed.
M & L for form work of rough finished flat surface of sides and soffits of floor or roof beams beam haunching, girders, bressummers, lintel , cantilevers, shelves including supports overhangs etc also splays between floors and beams etc complete all as specified and directed.
M&L for form work to rough finished flat surfaces of soffits of suspended slab such as roof slab Floor slab, shelves and chajjas etc not cxc 200mm thick (Horizontal or sloping) complete all as specified and directed.
Formwork rough finished surfaces of concrete to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed.
M&L Damp proof course in cement conrete 1:2:4type B-0 40mm thick to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed
M&L for Prepration of newly plastered surface and applying three coat of white wash as on ceiling complete all as specified and directed.
M and L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L Hardcore of borkan bricks, gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate as in floor finishing fair and even complete all as specified and directed.
S&F glazed ceramic coloured tiles thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface complete all as specified and directed.
S&F pressed steel frames 1.25mm thick for door size of frame125 X 60mm with single or double rebates including necessary fixing lugs, hinges, lock strike plate and filling of chowkats with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) and for filling of hold fast and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges and complete all as specified and directed.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mmx25mm double rebated comprises of glazed & gauged skelton shutter of (required no of gauged shutters and glazed shutters with or without AC opening) ERW section 50mmx20mm & 1mm thick with one or two openable leaf consisting of two number sash bars of T-Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T-Section of size 60mmx25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 (four Nos for each window) including following fittings welded to the frame shutter :- Ref Drg No CE JZ/TD-06/07 (i) Hold fast 150mm long mild steel flat iron 12x3mm made to shape- 04 Nos per window (ii) Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf. (iii) MS tower bolt 150mm long 2 No per leaf. (iv) Z section 20mmx25mm, 100mm long stopper – 01 Nos per leaf. (v) Cleat 55mm long of hollow square 15mmx12mm - 02 Nos per leaf (vi) Fabrication and fixing arrangements as per Drg No CE JZ/TD-06-07 (vii) MS Guard bars 12mm square bars @ 12cm c/c fixed horizontally
S&F 35mm thick Flush shutters , solid core construction , with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. ISI Marked.
S&F IInd class hard wood Glazed and skeleton shutters 35mm thick divided into square, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a) ; supplied and fitted to chowkats complete all as specified and directed
S&F GI wire cloth, 0.56 mm nominal dia. of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
S&F Sheet glass, 3mm thick ordinary quality, in squares, not exceeding 0.50 sqm in each pane including wooden beading fixed nails complete all as specified and directed
S&F 300mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 300 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm complete all as specified and directed.
S&F 300 mm long ordinary rat tail rod pattern spring, including roller and roller plate complete all as specified and directed.
M&L two coats of synthetic enamel painting on wooden surfaces of any description over 10 cm in width or girth not otherwise described above pink primer including prepration of surfaces complete all as specified and directed.
M & L for PCC (1:2:4) type B-0 (12.5 mm graded stone aggregates) as in filling of hold fast, roof kerbs, sloping padding in roof slab or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for preparation of surfaces and applying bituminous primer @ 0.30 ltrs/ sqm complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc complete all as specified and directed
S&F (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire roof area with over lapping 100mm to either sides and sealed in after cleaning down the roof by brooms complete all as specified and directed.
M&L for 40 mm thick brick tiles laid over 15 mm thick screed bed in cement mortar 1:6 and jointed, grouted flush in cement mortar 1:3 mixed 5% of crude of by weight of cement on roof padding flush pointing in CM 1:3 complete all as specified and directed.
S&F mild steel Gde Fe-410-W as in stairs ( framed) including stringers, treades,landing,balusters, hand rails etc. including cleats , brackets etc complete all as specified and directed.
E/M PORTION M & L for Point wiring with PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm, FRLS through and including concealed PVC conduit with fittings and PVC insulated, unsheathed multistranded, copper conductor cable continious earth wire of size 1.5 sqmm, FRLS, connected to common earth and modular sunken boxes for mounting of accessories complete for one light point/fan point/ call bell point controlled by one one way swithch all as specified and directed. One light/fan/bell point controlled by one one way modular switch.
All as per item no 69 above but in One 5 pin socket outlet 5 Amps on independent board.
All as per item no 69 above but in One 5 pin socket outlet 5 amps on same board
All as per item no 69 above but in One modular socket 6A multipin 2 module on independent board.
All as per item no 69 above but in modular socket, 6A multipurposes 2 module on same board.
All as per item Ser No 69 but cable size 2.5 sq mm , FRLS, for One modular socket 16A multipin 2 module on independent board
All as per item Ser No 69 but wiring with 2.5 Sqmm FR copper wire including earth wire 2.5 Sqmm of copper for 15 Amps 3 pin socket outlet.
M&L for sub main wiring with two single core multi stranded PVC insulated, unsheathed copper conductor of grade 1100 Volt , FRLS cable of size 6 sqmm (red for phase and black for neutral) and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 32 mm wide & 6 sqmm multistranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth duly complete and taking down old unserviceable one. Note :- (a) Three run of cable alongwith PVC conduit together shall be measured as single run.
M&L for sub main wiring with two single core multi stranded PVC insulated, unsheathed copper conductor of grade 1100 Volt , FRLS cable of size 4 sqmm (red for phase and black for neutral) and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 25 mm wide & 4 sqmm multistranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth duly complete and taking down old unserviceable one. Note :- (a) Three run of cable alongwith PVC conduit together shall be measured as single run.
M&L for sub main wiring with two run of 4 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FR cable in and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 20 mm wide & 4 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.
S&F triple pole and earth encolsure with a three pin and earth plug with socket with triple MCB 20 Amps complete with one triple pole MCB.
S&F modular switch one way ,1 module 6 amps single pole complete all as specified and directed.
S&F modular socket 6A multipin complete all as specified and directed.
S&F modular switch 1 way, 16 amps, 1 module single pole complete all as specified and directed.
S&F modular socket, 6A/16A multipin combined 2 /3 module complete all as specified and directed.
S&F modular socket, 2 module 6A 2/3 pin complete all as specified and directed.
S&F in replacement surface mounting universal batten housing made of powder coated CRCA sheet fixed on and including 02 Nos PVC square blocks suitable for and upto 1 x 18/20 W LED tube rod single sided in taking down old unserviceable fitting complete all as specified and as directed.
S&F surface mounting universal batten housing made of powder coated CRCA sheet fixed on and including 02 Nos PVC square blocks suitable for upto 1 x 18/20 W LED tube rod complete all as specified and as directed.
S&F LED tube light 20W ultra bright LED polycarbonate tubelight with very high efficacy suitable for fitting into tube light batten fittingt all as directed Note :- The contractor will submit the LM-80 and LM-79 report from manufacturer to Engineer-in-Charge before incorporating the items in work.
S&F LED tube light 20W (single sided connection) ultra bright LED polycarbonate tubelight with very high efficacy suitable for fitting complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
S&F in replacement of modular fan regulator 2 module electronic type 5 step 100watt,240 Volt and connecting complete all as specified and directed all as directed.
S&F fan regulator electronic type 5 step 100 watt and connecting to C/Fan complete all as specified and directed all as directed.
S&F lamp holder PVC body angle type including 9 watt LED bulb polycarbonate body complete all as specified and directed.
M&L ceiling rose, surface bakelite 65x50mm three terminal complete all as specified and directed.
S &F modular white cover plate with frame, 1 module complete all as specified and directed.
S &F modular white cover plate with frame, 3 module complete all as specified and directed.
S &F modular white cover plate with frame, 8 module complete all as specified and directed.
S &F modular white cover plate with frame, 12 module complete all as specified and directed.
S &F modular metal flush box, 1 module complete all as specified and directed.
S &F modular metal flush box, 3 module complete all as specified and directed.
S &F modular metal flush box, 8 module complete all as specified and directed.
S &F modular metal flush box, 12 module complete all as specified and directed.
S&F in replacement GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long MS clamps made out of MS flat iron of size 32 mm thick with nuts & bolts, washers complete including dismentling the existing GI pipe bracket and drilling of holes for nuts & bolts etc complete all as specified and directed.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supplying and fixed in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed. Note : All the connection of incoming and out goiing wire in MCB will be made with thimble with suitable size as directed.
S& F in repair MCB single pole 6 amps to 32 amps , 'B' series complete all as specified and directed.
All as per item Ser No105 here-in-before but 'C' series complete all as specified and directed.
All as per Item Ser No 105 above here-in-before but single pole and neutral 40 amps , C series complete all as specified and directed.
All as per item Ser No 105 above but single pole and neutral 6 amps to 32 amps , 'C' series complete all as specified and directed.
Material and labour for replacement of distribution board made out of CRCA sheet DB vertical type double door TPN 4 Way MS sheet including fixing in the wall,cutting chases grounting and necessary patch work and white wash to match with the existing including making connections all as directed containing the folowings:- Note :- All the connection of incoming and out goiing wire in MCCB and MCB will be made with thimble with suitable size as directed. (a) MCCB 4 Pole 63 Amps 16 KA breaking capacity with thermal release 01 No (In coming) (b) Bus bar 200 Amp rated mode out of Aluminium on insulated duly insulated wire adhesive tape RYB & black-4 Nos (c) MCB SPN 40 amp-04 Nos,MCB SP 40 Amp-04 Nos (Out going) (d) Connection from MCCB to bus bar will be made with Aluminium Strip suitable size as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out complete all as specified and directed.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified complete all as specified and directed.
Removing excavation material n. exc 50 mtr and depositing wher directed at a level n. exe 1.5 mtr above the starting point.
Supply and lay brick common burnt sub class "B" old size and for protection of cable laid in trenches for under ground cable all as specified.
M & L Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified
M&L for cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 40 mm bore with necessary clamps all as directed.
Supply and fix exhaust fan, steel body AC single Phase 230V of size 300mm sweep with blades and frame and louvers incl cutting and making hole of suitable size complete all as specified and directed.
Supplying and fixed in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed.
Supply and laying LT cable XLPE insulated armounded heavy duty electric cable with aluminium conductor cable 1100 volt grade 16 Sqmm 2 core complete all as specified and directed.
M & L for earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common saft filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia ( 8 SWG) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron light grade pipe 15mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 5 of SSR 2009( Part-I).
D.RAJ And CO.
M/s kulwant singh and sons
GORAYA AND CO
Harbhajan electric co
AVTAR SINGH RAJU
S S CONSTRUCTION
RATTAN CHAND CHANDAN AND CO
buta singh and sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .