Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.4 L+₹1,765 (0.33%)Rejected-Finance | L2 | Rejected-Finance DUE TO L2 BIDDER | |
| 3 | L3₹5.9 L+₹48,410 (9.00%)Rejected-Finance 261 3 BESIDE ROYAL HOSPITAL KAMLA NEHRU NAGAR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance DUE TO L3 BIDDER | |
| 4 | L4₹6.8 L+₹1.4 L (25.8%)Rejected-Finance | L4 | Rejected-Finance DUE TO L4 BIDDER |
Tender Value
Refer Docs
EMD Value
₹15,600
Closing Date
4 Nov 2023, 6:00 pmClosed
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
REPAIR/REPLACEMENT OF INTERNAL WIRING INCLUDING FITTINGS AND FIXTURES OF CENTRAL INSTITUTES AT AEC TRG COLLEGE AND CENTRE, PACHMARHI
2023_MES_621942_1
CA No. AGE(I)/PACH/of 2023-24(8565/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
Class E category b(i)
7 documents required · 7 mandatory
₹500
Yes
AGE(I) PACHMARHI
₹15,600
20 Nov 2023
6 Oct 2023
7 Nov 2023
6 Oct 2023
4 Nov 2023
21 Oct 2023
Amount
M&L for taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point re-wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm including covered with modular plate and frame white for one light point controlled by one switch complete all as specified and directed.
All as per item No 2 above but one fan point controlled by one switch complete all as specified and directed.
All as per item No 2 above but one light point controlled by two, two way switches complete all as specified and directed.
All as per item No 2 above but one socket outlet 6 amp controlled by one switch on the same board with other switches complete all as specified and directed.
All as per item No 2 above but one socket outlet 6 amp controlled by one switch on indepdendent board complete all as specified and directed.
All as per item No 2 above but one bell point controlled by one bell push complete all as specified and directed.
M&L for point re-wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 25x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm including covered with modular plate white for one 16 amp socket outlet controlled by one switch on independent board complete all as specified and directed.
S&F modular switch one way 6 amp 1 module complete all as specified and directed.
S&F modular switch one way 16 amp 1 module complete all as specified and directed.
S&F modular switch two way 6 amp 1 module complete all as specified and directed.
S&F modular bell push, 6 amp, 1 module complete all as specified and directed.
S&F door bell, AC, 240 volts, single pole complete all as specified and directed.
S&F modular socket 6/16 - 2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket 6 amp 2/3 pin combined 2 module complete all as specified and directed.
S&F modular hum free electronic step fan regulator, 100 watt 2 module complete all as specified and directed.
S&F angle holder, insulated polycabonate body with back plate complete all as specified and directed.
S&F ceiling rose 3 plates polycarbonate body complete all as specified and directed.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of 14 but 2x4 sqmm + 1x4 sqmm earth wire complete all as specified and directed.
All as per item No 19 above but 2x6 sqmm + 1x6 sqmm earth wire complete all as specified and directed.
S&F LED Smart bright batten (1150mm) made of PC housing integrated LED driver with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and directed.
S&F LED Smart bright batten (600mm) made of Aluminium housing integrated LED driver with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not less than 9 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and directed.
S&F energy efficient recessed mounted LED luminaire 36 Watt suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required complete all as specified and directed.
S&F in renewal 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp complete all as specified and directed.
S&F SPN DB (Double Door), 240 volts, 4 ways MCB distribution board powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 54 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces complete all as specified and directed.
All as per item No 25 above but SPN DB (Double Door), 240 volts, 8 ways complete all as specified and directed.
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of single pole 6 to 32 amp complete all as specified and directed.
All per item No 27 above but double pole 10 to 32 amp complete all as specified and directed.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete all as specified and directed.
Taking down carefully aluminium or copper submain wiring with PVC casing caping / PVC surface conduit and making good disturbed surfaces complete all as specified and directed.
GHASI RAM SAHU
MISHON TRADING CORPORATION
MODI CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .