| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹86,201.05 (0.72%)Admitted-Finance | ₹1.2 Cr+₹86,201.05 (0.72%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹18.8 L (15.6%)Admitted-Finance R O PATTA PALOURA 11 BAKSHI ENCLAVE JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹1.4 Cr+₹18.8 L (15.6%) | L3 | Admitted-Finance |
| 4 | L4₹1.4 Cr+₹24.2 L (20.2%)Admitted-Finance | ₹1.4 Cr+₹24.2 L (20.2%) | L4 | Admitted-Finance |
| 5 | L5₹1.5 Cr+₹28.2 L (23.5%)Admitted-Finance | ₹1.5 Cr+₹28.2 L (23.5%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ABHINANDAN SHARMA L3 | zakir hussain L4 | AMIT SHARMA L1 | M/S CHAMAN LAL L5 | Balbir Singh L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m | ||||||||
| 1.10 | All kinds of soil. | 330.22 | cum | 200 ₹66,044 | 170 ₹56,137.4 | 116 ₹38,305.52 Lowest | 200 ₹66,044 | 150 ₹49,533 |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 198.13 | cum | 150 ₹29,719.5 | 80 ₹15,850.4 | 144 ₹28,530.72 | 100 ₹19,813 | 50 ₹9,906.5 Lowest |
| 3.00Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : | ||||||||
| 3.10 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) | 93.83 | cum | 2,900 ₹2,72,107 | 3,000 ₹2,81,490 | 2,800 ₹2,62,724 | 3,200 ₹3,00,256 | 2,750 ₹2,58,032.5 Lowest |
| 3.20 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | 157.4 | cum | 3,900 ₹6,13,860 | 4,000 ₹6,29,600 | 3,840 ₹6,04,416 | 4,200 ₹6,61,080 | 3,800 ₹5,98,120 Lowest |
| 4.00Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shutteringand finishing with. | ||||||||
| 4.10 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 1.1 | cum | 6,500 ₹7,150 | 7,000 ₹7,700 | 6,400 ₹7,040 | 7,000 ₹7,700 | 6,000 ₹6,600 Lowest |
| 5.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth and curing complete. | 49.63 | sqm | 300 ₹14,889 Lowest | 500 ₹24,815 | 416 ₹20,646.08 | 500 ₹24,815 | 385 ₹19,107.55 |
| 6.00 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. | 244.82 | meter | 30 ₹7,344.6 | 50 ₹12,241 | 28 ₹6,854.96 | 50 ₹12,241 | 20 ₹4,896.4 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
6 Nov 2023, 4:00 pmClosed
Estates Officer
Estates Division SKUAST-Jammu Main Campus, Chatha
Construction of Centre for Holistic development of sericulture at Main campus Chatha (Technological Interventions to Strengthen Sericulture in UT of Jammu and Kashmir)
2023_SKUST_233914_3
AU/Estates/23-24/10 dated 09-10-2023
Open Tender
Civil Works
Item Rate
360 days
Main Campus Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹2,000
Assistant Comptroller Estates SKUAST Jammu
₹3.0 L
16 Nov 2023
18 Oct 2023
7 Nov 2023
18 Oct 2023
6 Nov 2023
18 Oct 2023
Amount
Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shutteringand finishing with.
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth and curing complete.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, walls, bases of columns, etc. for mass concrete.
Shelves (Cast in situ)
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Columns, Pillars, Piers, Abutments, Posts and Struts.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
Cold twisted/TMT bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1: 6 (1 cement: 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :
Cement mortar 1: 4 (1 cement: 4 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete :
Providing and fixing aluminium D handles ISI marked (powder coated) with necessary screws etc. complete :
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Single rubber stopper
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm.
Providing and fixing of 40 mm granite moulding on top of granite walls/dados including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Size of tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.
Size of tile 600x600 mm
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1 : 2011 (Board with BIS certification marks)
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge.
With average thickness of 120mm and minimum thickness at khurra as 65 mm
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
In 75x75mm deep chase
12 mm cement plaster of mix : (Inside)
1:6 (1 cement: 6 fine sand)
18mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 6 (1 cement : 6 fine sand) (Outside plaster)
6 mm cement plaster of mix :
1:3 (1 cement: 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with Acrylic Smooth exterior paint of required shade : :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Providing and laying stone soling including hand packing, filling the interstices with crushed aggregate, sand, watering, compacting by hand ramming.
Providing and laying RBM (River Bed Material) including loading, carrying, unloading, spreading, compacting and watering complete item.
Providing and injecting chemical emulsion for pre/post constructional Anti-termite treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor,along the external perimeter of building,expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipe and conduits with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to 1% concentration, labour, HOM of equipments, complete as per specifications.(plinth area of building at ground floor only shall be measured).
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete
Inside size
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) ), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing following PVC pipes alongwith necessary assesories and fitting (such as tee, elbow, bends etc )complete items
PVC pipe (100 mm nominal dia)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings.
Flat back wash basin of size 550x400 mm.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing Stainless Steel A Isis 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink without drain board
610x460 mm bowl depth 200 mm.
Providing and fixing C.P. brass sink /wash basin mixer of approved quality
15 mm nominal bore.
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing 100 mm CP grating.
Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour
15 mm nominal bore with 30 cm length.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15 mm nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c trenching and refilling.
25 mm dia. nominal bore
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5.00 mm thickness
Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment)
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in- plate etc. complete as per the direction of Engineer-in-charge
With Stainless Steel cover plate minimum 1.25 mm thickness
Wall lining butch work upto 10 m height with Dholpur stone 40mm thick rough facing on the exposed surface with stone strips of minimum length 300mm and required width including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75 x 75mm and by providing layer of 75 thick strips including 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including ruled pointing in cement mortar 1: 2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of the stone and curing complete as per the directions of engineer-in-charge.
Carriage of materials by mechanical transport including loading, unloading and stacking (10km)
Sand, stone aggregate below 40 mm nominal size
Bricks
SUB-DISTRIBUTION BOARDS
Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
Single Pole
Triple Pole and neutral
Triple Pole
Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
40 amps SPN
63 amps SPN
EARTHING AND LIGHTNING PROTECTION
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection.
Providing and fixing 25 mm x 5mm GI strip from earth electrode as required
DISTRIBUTION BOARD
Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings.
Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100%
All metering current transformers shall be Class 1, 15 VA.
MDB-1 (Indoor Type)
Incomer (Power panel)
250 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
200A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Outgoing
40 Amp TPN - 5 No.
63 Amp TPN - 5 No.
40 Amp SPN - 5 No.
63 Amp SPN - 5 No.
MDB-1 (Indoor Type)
Incomer
160 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
200A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Outgoing
40 Amp TPN - 2 No.
63 Amp TPN - 2 No.
40 Amp SPN - 5 No.
63 Amp SPN - 5 No.
Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required.
3.5C x 95 sq.mm
3.5C x 120 sq.mm
SUB-DISTRIBUTION BOARDS
Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
8 way TPN
4 way TPN
12 way TPN
Supply and fixing 1x20 watt box type fitting complete with extruded alulminium tube rod including connection testing etc. as reqd. (CAT No. DMLNLT8-16 and LTT8-20)
Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL)
Supply and fixing of 36 Watt LED Panel 2'-0"x2'-0" including connection testing etc as reqd.
Supply and fixing of 12 Watt LED Panel surface mounted including connection testing etc as reqd.
Supply and fixing of 18 Watt LED Panel concealed including connection testing etc as reqd.
Supply and fixing of 9 Watt LED mirror light 2' long including connection testing etc as reqd. (CAT No. LCTL-09-CDL)
Supplying and fixing of 70 watt LED street light with G.I. pipe bracket with all accessories including connection testing etc as reqd.
Wiring for telephone point with 0.61 mm dia copper conductor unarmoured shielded twisted telephone wire in 25mm dia existing PVC conduit, connections etc. complete as required as per specification and drawings.
Supplying and fixing telephone socket outlet housed in zine passivated box with suitable connector strip in recessed wall/partition as reqd.
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit (2 mm thick) with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in the front on surface or in recessed, including providing and fixing of six pin 5/6 Ampere modular socket and 5/6 amp modular switch including connection testing etc. as reqd.
Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required
Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required
Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
2x6 sq mm with 1x6.0sqmm earth wire
2x10 sq mm with 1x6.0sqmm earth wire
4x6sq. mm with 2 x 6.0sq. mm earth wire
Wiring for sub main wiring with4x10 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd.
Wiring for twin control light point with 2x1.5 sqmm PVC insulated copper conductor cable in surface/recessed ISI marked PVC conduit with 2 way 6 Ampere switch
Supplying and fixing suitable size G.I. box with modular plate and cover in the front on surface or in recessed, including providing and fixing of six pin 5/6 and 15/16 Ampere modular socket outlet and 15/16 Amp modular switch including connection testing etc. as reqd.
Supply and fixing of 250 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing of 200 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supplying and fixing step up electronic fan regular on the existing switch box including connection, testing etc. as reqd.
Supplying and fixing of exhaust fan 300mm sweep heavy duty trans air with double ball bearing including connection, texting etc. as required.
Supply and fixing Call bell / buzzer DC / AC single phase 230 V complete
Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required
Supplying and fixing of 63 Ampere TPN in the existing distribution board including connection testing etc as reqd.
Supply and fixing 2 Hp single phase monoblock pump set covered with shed of suitable size made of 16 SWG MS sheet including its painting and with small outdoor panel with bus bar 32 TPN with single phase starter including testing commissioning etc. required
Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess.
Providing and fixing wall fan 16" sweep including connection testing etc required
Balbir Singh
ABHINANDAN SHARMA
zakir hussain
M/S CHAMAN LAL
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TermsandConditionsoftheContract.pdf
Tender Documents • 0.22 MB
BOQ_684353.xls
BOQ • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .