Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 308 CREATIVE INDUSTRIAL ESTATE SUNDAR NAGAR LANE 2 KALINA SANTACRUZ EAST MUMBAI 400 098 | MUMBAI | MUMBAI | MAHARASHTRA | 400098 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 8 1 97 NITHINAA S HIGH S PEDAWALTAIR VISAKHAPATNAM 530017 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530017 | Admitted-Finance |
| 5 | Admitted-Finance INFINITY THINK TANK TOWER II 10TH FLOOR PLOT NO A3 BLOCK G SECTOR V SALT LAKE CITY KOLKATA 700091 WB | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
26 Feb 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
T S GANESH KUMAR
A-4 BLOCK A SECTOR 1 NOIDA UTTAR PRADESH 201301
CONSTRUCTION POWER
2021_NRL_611101_1
TPFMC/CONS/NRL/082176C/006
Open Tender
Electrical Works
Works
180 days
NUMALIGARH REFINERY
PLEASE REFER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹0
Exempted
ONLINE
22 Mar 2021
22 Jan 2021
27 Feb 2021
22 Jan 2021
26 Feb 2021
11 Feb 2021
5 Feb 2021
120 days
Amount
EXCAVATION Earth work in excavation for all kind of Soil including all labour, materials, dressing of sides, pumping & bailing out water accumulated due to rain and / or subsoil waters and including disposal or stacking, leveling and neatly dressing as decided by Engineer-in-Charge including providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., if any, complete, all materials and labour complete and as directed by Engineer-in-Charge for following depth. Excavated soil shall be disposed at least up to the distance of 500 meter from the plant Boundary (Unit Area Boundary) for backfilling and the charges for the same is included in this item.
Same as 1.0 but From grade level upto 1.5m depth
Same as 1.0 but From 1.5m depth to 3.0m depth
BACKFILLLING WITH Wet Mix Macadam (W.M.M) Treatment of Foundation below level for required thickness as per construction drawings with Wet Mix Mecadam, supply of material,transportation,labours etc., Laid in layers of maximum 150mm thickness and ramming to proper compaction to achieve 85% relative density as per IS 2720 part XIV. Before providing the above treatment the base of the foundation pit shall be compacted to 95% of maximum dry density as per IS 2720 part VII, dressing etc., all completed and as per directions of Engineer-In-Charge. Rate for compacted thickness shall be considered.
EARTH DISPOSAL Transportation of surplus earth/debris to dumping area outside site Carting the surplus excavated earth/rocks and debris from construction area beyond the initial lead of 500 meters to the approved dumping area outside the plant boundary at any distance from the site, including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths/heights, stacking, levelling and dressing both the area (viz. from where the earth is carted and where it is deposited) to required levels and slopes complete with all lifts. Any payment of fee and duties for using the dump. Note : Outing gate of Refinery shall be decided by NRL / EIC as per the site condition
Same as 4.0 with Transportation to any designated area within plant boundaries beyond 500 m
Same as 4.0 with Transportation to any demarked area outside plant boundary, lead upto 2km from gate of refinery
Same as 4.0 with Transportation to any demarked area outside plant boundary, beyond 2km upto 5km from gate of refinery.
Same as 4.0 with Transportation to any demarked area outside plant boundary, beyond 5km upto 10 km from the gate of refinery
LEAN CONCRETE (PCC 1:4:8 M7.5) Providing and laying in position Plain Cement Concrete 1:4:8 (1 Cement: 4 Coarse Sand: 8 Graded Stone Aggregates) with 40 mm and down size graded stone aggregate as leveling course in foundations, under slabs on grade etc., including tamping, curing, shuttering etc. complete for all depths and heights. For details refer specification for Plain and Reinforced concrete (NR-0ZZZZ-CV-SPE-0002). Materials to be supplied as per approved vendor lists attached with special conditions of contract.
FOUNDATION CONCRETE Providing and laying in position Reinforced Cement Concrete of specified grade( design mix ) with 20 mm and down size graded stone aggregates excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and even surface etc. including cost of all material & labor in substructure, for rafts, plinth beams, footings and other similar items not specifically mentioned herein, for all depths, complete as per drawings, specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete (NR-0ZZZZ-CV-SPE-0002). Materials to be supplied as per approved vendor lists attached with special conditions of contract. Quoted Price shall include Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE ( MASTERLIFE CI 220 or equivalent) in concrete as per manufacturer's specification for protection of reinforcement against corrosion. Supply of admixture in Contractor's scope.
Same as item 6.0 above with M-30 grade of concrete
Supply and installation of 50mm dia PVC sleeves (embed in concrete foundation), including tools, equipment and labour necessary to complete the work.
PLAIN CEMENT CONCRETE (PCC 1:3:6 M10) Providing and laying in position Plain Cement Concrete 1:3:6 (1 Cement: 3 Coarse Sand: 6 Graded Stone Aggregates) with 20 mm and down size graded stone aggregate as concrete in foundations, for trays pedestal/foundation block etc., including tamping, curing, shuttering etc. complete for all depths. For details refer specification for Plain and Reinforced concrete (NR-0ZZZZ-CV-SPE-0002). Materials to be supplied as per approved vendor lists attached with special conditions of contract.
DEFORMED/TMT STEEL BARS FOR CONCRETE REINFORCEMENT Supply and fixing in position TMT reinforcement bars Fe500D conforming to IS-1786 (FY=500 MPa) for RCC work including the cost of steel and cost of binding wire, carting the same to site of work, straightening, cleaning, cutting, binding with 18 SWG black soft annealed binding wire, and placing with proper cover blocks, supports, chairs, spacers, complete for all heights and depths complete as per drawing & specification. Materials to be supplied as per approved vendor lists attached with special conditions of contract. For payment reinforcement including authorized weight for spacer bars, laps, chairs etc shall be measured separately for diameter wise length actually used. Wastages & unauthorized laps shall not be considered for payment. Inspections and Tests as per relevant technical specifications and codes shall be deemed to be included in the scope
SUPPLY AND INSTALLATION OF ANCHOR BOLTS Fabricating, supplying and installing thread Anchor Bolts of specified diameter conforming to IS 2062 Grade BR as per drawings, including the cost of M.S. rounds and plates, nuts, washers , anchor plates, fine plates, stiffness, pipes sleeves etc, material as per relevant IS codes, fixing in position with necessary, tools, templates, labour etc for all heights and depths, all complete. Materials to be supplied as per approved vendor lists attached with special conditions of contract.
FORM-WORKS FOR FOUNDATION CONCRETE Providing and fixing plywood centring and shuttering straight / inclined, in foundations for footings, equipment foundations, pedestals etc. including keeping the same in position during concreting and removal of the same after specified period, keeping necessary provision for inserts, projecting dowels etc., tools, equipments and labour necessary for the work all compete, and as specified and directed.
SURFACE TREATMENT OF FOUNDATION Providing surface treatment to foundations in contact with aggressive water or soil in form of linings, membranes, mastic seal, coal tar epoxy paint, bitumen paint / layer, mortar fillet, protection board etc including materials, tools and tackles as specified in the Drawings, specifications and directions of Engineer-in-charge. Inspections and Tests as per relevant specification / IS codes shall be deemed to be included in the scope
Same as 11.0; Bitumen Paint/ Layer : Surface Treatment of Foundations using Bitumen Paint / Layer - two coats of hot bitumen paint of grade 20/30 with quantity of bitumen at least 1.2 kg/sqm per coat
NON-SHRINK GROUT FOR STRUCTURAL STEEL COLUMNS/ POSTS/ EQUIPMENT Supply and laying non-shrinking grout with a minimum crushing strength of 40 N/mm2 for grouting under base plates, base frames or other anchoring elements for structures and/or machines, including cleaning of surfaces, form-works, chamfering of edges, smoothing of exposed surfaces, providing all tools and labour necessary to complete the work as per drawings / specifications and as directed. The non shrink grout shall be laid as per approved vendor‘s specification ( SIKA/FOSROC make)
STRUCTURAL STEEL Supplying, fabricating and erecting in position steel structures conforming to IS : 2062 grade BR comprising of rolled and built up sections for side runners, beams, columns, trussed girders, sag rods, etc., including the cost of straightening if required, cutting to required size bolting and or welding of joints as per drawings, Surface preparation SSPC-SP-10, painting with one coat of 60 micron DFT of inorganic zinc silicate primer, 1 coat of 100 micron Two pack Epoxy HB Poly amide cured, fixing in line or level with temporary staging, complete with all tools, equipments and labour for all depths and heights as per drawings and directed. Materials to be supplied as per approved vendor lists attached with special conditions of contract.
Same as 13.0 for Tray supports at Grade level
Same as 13.0 but for Structural Steel Inserts, w/ TMT Fe 500D lugs & exposed surface painted
Grubbing, scrubbing & clearing the areas, removal of roots/boulders, breaking clods, making up the hollow produced by removal of roots/boulders with available earth, clearing the site of all objectionable/unserviceable materials by means of manual or mechanical excavation as per directions of Engineer-in-Charge. The cutting and stripping work shall be done to an average depth of 300 mm and the surface rough-levelled for subsequent works. Including loading, transport, unloading and disposal of the unserviceable material at designated areas within the plant boundary and leveling the same.
Description of Work / Item(s)
Amount
Outdoor Type 11 kV Switchgear Supply, transportation up to erection site, Installation, Earthing, Testing, Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Switchboards, assembly, positioning in place, mounting and wiring of loose supplied part by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections as per attached approved SLD Drawing No. TP-1C93A-EL-SLD-0001, including supply of all wiring materials, drilling of gland plates for cable gland fixing, plugging of unused cable entries etc. Including supply and application of grouting materials, foundation bolts, plugs for unused cable entries, hardware materials, touch up painting as required, wiring material & copper lugs for wiring. Complete with labour & materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope.
11kV, 630A, 50 Hz, 40kA for 1 sec, HV Switchgear(VCB Breaker Panel) with Integral Base Frame, Enclosure protection : IP55 with canopy, suitable for outdoor installation (Panel Tag No : HT-RSS). Supply shall include commissioning spares as required.
11kV, 630A, 50 Hz, 40kA for 1 sec, HV Switchgear(VCB Breaker Panel) with Integral Base Frame, Enclosure protection : IP55 with canopy, suitable for outdoor installation (Panel Tag No : HT-001). Supply shall include commissioning spares as required.
11kV, 630A, 50 Hz, 40kA for 1 sec, HV Switchgear(VCB Breaker Panel) with Integral Base Frame, Enclosure protection : IP55 with canopy, suitable for outdoor installation (Panel Tag No : HT-004). Supply shall include commissioning spares as required.
Mandatory spares parts / items for above outdoor type 11KV HV Switchgear for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Supply of Outdoor Type 11 kV Switchgear 11kV, 630A, 50 Hz, 40kA for 1 sec, HV Switchgear(VCB Breaker Panel) with Integral Base Frame, Enclosure protection : IP55 with canopy, suitable for outdoor installation. The switchboard will be identical to 11KV Switchboard - HT-RSS as per attached approved SLD Drawing No. TP-1C93A-EL-SLD-0001 and number of fedders will also be same as HT-RSS. Supply shall include commissioning spares as required.
In-door Type 11 kV Switchgear Supply, transportation up to erection site, Installation, Earthing, Testing, Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Switchboards, assembly, positioning in place, mounting and wiring of loose supplied part by equipment vendor, interconnection of shipping sections and requisite interpanel wiring between shipping sections as per attached approved SLD Drawing No. TP-1C93A-EL-SLD-0001, including supply of all wiring materials, drilling of gland plates for cable gland fixing, plugging of unused cable entries etc. Including supply and application of grouting materials, foundation bolts, plugs for unused cable entries, hardware materials, touch up painting as required, wiring material & copper lugs for wiring. Complete with labour & materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope.
11kV, 630A, 50 Hz, 40kA for 1 Sec, HV Switchgear(VCB Breaker Panel) with Integral Base Frame, Enclosure protection : IP4X, suitable for Indoor installation, (Panel Tag No :HT-002). Ethernet switch will be provided sothat all meters, numerical relays can be connected to Plant SCADA / SAS via ethernet switch. One number Cable Earthing Truck and one number bus earthing truck / trolley will be supplied along with 11KV Switchboard suitable for both Incoming feeder and outgoing feeder. Supply shall include commissioning spares as required.
11kV, 630A, 50 Hz, 40kA for 1 Sec, HV Switchgear(VCB Breaker Panel) with Integral Base Frame, Enclosure protection : IP4X,suitable for Indoor installation, (Panel Tag No :HT-003). Ethernet switch will be provided sothat all meters, numerical relays can be connected to Plant SCADA / SAS via ethernet switch. One number Cable Earthing Truck and one number bus earthing truck / trolley will be supplied along with 11KV Switchboard suitable for both Incoming feeder and outgoing feeder. Supply shall include commissioning spares as required.
Replacement of existing Metering CT, by Supply, Installation, Testing and commissioning of new 400/5A CL.1,15VA Metering CT at 11kV Existing Switchgear-SWBD # 201-P03 feeder and P05 feeder located at SS-CPP and associated activities.
Replacement of existing Protection CT, by Supply, Installation, Testing and commissioning of new 400/5A CL.5P20, 15VA Protection CT at 11kV Existing Switchgear-SWBD # 201-P03 feeder and P05 feeder located at SS-CPP and associated activities.
Supply, Installation, Testing & Commissioning of 400/5A CL.PS,15VA CT and Cable Differential Protection Relay (87L) for 11kV Existing Switchgear-SWBD # 201 for P03 feeder and P05 feeder located at SS-CPP and associated activities.(The make of the CTs shall be similar to the one supplied for the new 11kV Switchgear panels( HT-002 and HT-003)
400/1/5A CT Testing and 1250A breaker testing of P03 feeder at 11kV Existing Switchgear SWBD # 200
Mandatory spares parts / items for above Indoor 11KV HV Switchgear for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Package Compact substation (CSS) Supply, transportation up to erection site, Installation, earthing (all internal earthing and connection of internal earth with outside grid) testing and commissioning of outdoor type following Compact Substations (CSS) consisting of HV VCB (RMU) and MV distribution boards, transformers, power factor improvement capacitors, misc. electrical panels including all labour and materials, as per attached approved SLD Drawing No. TP-1C93A-EL-SLD-0001 with this tender and directions of Engineer-in-Charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope. Each package substation shall consist of : ● 630A, 11kV, 3 phase,50Hz, 25kA for 1 second, VCB Breaker Panel consist of 3 nos VCB. (RMU-1 number VCB for incomer and 2 numbers VCB for outgoing feeders as loop in-loop out). ● 11kV/433V, 3 Phase, Dyn11, OCTC with tapping range of ±5% in steps of 2.5%, ONAN type Energy efficiency Level 2 (minimum) as per IS 1180 OR Dry type cast resin natural air cooled (AN) Transformer with all fittings & accessories. ●415V, 3 Phase, 50Hz, 50kA for 1 second, MV Switchboard with ACB incomer & MCCB having O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection for outgoing feeders. ● KWH Meters in incomer & all outgoing feeders of MV switchboard ● All lighting and lighting distribution inside Package substation ● APFC panel with required protection. ● All protection & metering as required. • All internal earthing and connection of internal earth with outside grid
Compact Substation CSS-001 with 11kV/433V, 1600KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001. Supply shall include commissioning spares as required.
Compact Substation CSS-002 with 11kV/433V, 1600KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001. Supply shall include commissioning spares as required.
Compact Substation CSS-003 with 11kV/433V, 1600KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Compact Substation CSS-004 with 11kV/433V, 1600KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Compact Substation CSS-006 with 11kV/433V, 1600KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Compact Substation CSS-005 with 11kV/433V, 1250KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Compact Substation CSS-007 with 11kV/433V, 1250KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Compact Substation CSS-008 with 11kV/433V, 1250KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Compact Substation CSS-009 with 11kV/433V, 500KVA, Transformer with outgoings and cable terminations as per SLD Drawing No. TP-1C93A-EL-SLD-0001 Supply shall include commissioning spares as required.
Mandatory spares parts / items for above 1600kVA/1250KVA/500KVA Compact Substation for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Supply of Package Compact substation with 11kV/433V, 500KVA Transformer, identical to CSS-009, with same number of incoming & outgoing feeders as per SLD Drawing No. TP-1C93A-EL-SLD-0001. Supply shall include commissioning spares as required.
415V MV Switchgear / Auxiliary Distribution Boards Outdoor Type 415V MV Switchgear Supply, transportation up to erection site, Installation, Earthing, Testing, Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Switchboards, assembly, positioning in place, mounting and wiring of loose supplied part by equipment vendor, interconnection of shipping sections and requisite interpanel wiring between shipping sections as per attached approved SLD Drawing No. TP-1C93A-EL-SLD-0001, including supply of all wiring materials, drilling of gland plates for cable gland fixing, plugging of unused cable entries etc. Including supply and application of grouting materials, foundation bolts, plugs for unused cable entries, hardware materials, touch up painting as required, wiring material & copper lugs for wiring. Complete with labour & materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope.
415V MV Switchboard with FRP or Polycarbonate enclosure, 800A, 50 Hz, 40kA for 1 Sec ACB Switchboard, Enclosure protection : IP55 with canopy, suitable for Outdoor installation. (Panel Tag No : LV-001). Supply shall include commissioning spares as required.
Mandatory spares parts / items for above Outdoor type 415V MV Switchgear for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
415V MV Switchgear / Auxiliary Distribution Boards Indoor Type 415V Auxiliary Distribution Board Supply, transportation up to erection site, Installation, Earthing, Testing and commissioning of following 415V indoor type Auxiliary Power Distribution Boards
415V, TPN, 12 Way, 2mm thick CRCA sheet steel enclosure material, IP42, suitable for indoor installation, SS Name plate, Panel shall be supplied with cable gland for all incoming and outgoing feeders (additionally 5 nos dummy stopper plug for outgoing feeders). Incoming and outgoing feeders are as follows : Incomer feeder (One number) : 100A, 4 Pole MCB, R,Y,B Indication Lamp Outgoing feeder (Twelve number) : 4 Nos, 63A, 4P, MCB + 4 Nos, 32A, 4P, MCB + 4 Nos, 16A, DP, MCB
Feeder Pillars
Supply, transportation up to erection site, Installation, Earthing, Testing, Operational and Functional checking and commissioning of following 415V , 3 phase, TPN, 50Hz, 25KA for 1 second outdoor type feeder pillars complete with canopy for additional weather protection. Supply and fixing of cable lugs and double compression cable glands including all other sundry materials, transportation to site, proper storage, assembly, installation on concrete trenches/ foundation, aligning, levelling, testing, calibration of meters/ relays including all labour and materials complete as per specifications & SLD Drawing No. TP-1C93A-EL-SLD-0001 attached with this tender and approved drawings and directions of engineer-in-charge and suitable for termination of Incomer cable size as specified in the SLD Drawing No.TP-1C93A-EL-SLD-0001. All feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily :
● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Feeder pillars with FRP OR Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection ● 400A MCCB as Incomer Breaker. ● 2 Nos 160A MCCB, 3 Nos 125A MCCB, 4 Nos 63A MCCB, 2 Nos 32A MCCB(timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Feeder pillars with FRP OR Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection. ● 250A MCCB as Incomer Breaker. ● 2 Nos 160A MCCB, 2 Nos 125A MCCB, 3 Nos 63A MCCB, 2 Nos 32A MCCB(timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Feeder pillars with FRP OR Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection. ● 160A MCCB as Incomer Breaker. ● 4 Nos 125A MCCB, 3 Nos 63A MCCB, 2 Nos 32A MCCB (timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Mandatory spares parts / items for above Outdoor type 400A/250A/160A Feeder Pillar Box for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
CABLES
SUPPLY OF HV POWER CABLE, MV/LV POWER CABLES, CONTROL CABLES, FIBRE OPTIC CABLES
Supply of 11kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables of following sizes as per the attached Data sheet of cables :
3C x 300 Sqmm
3C x 240 Sqmm
3C x 185 Sqmm
Supply of 6.6kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables of following sizes as per the attached Data sheet of cables :
3C x 120 Sqmm
Supply of 1.1 kV Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables of following sizes as per the attached data sheet of cables:
1C x 630 Sqmm
3.5C x 300 Sqmm
3.5C x 240 Sqmm
3C x 95 Sqmm
3.5C x 50 Sqmm
Suuply of 1.1 kV Grade, CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables / control cables of following sizes as per the attached data sheet of cables :
14C x 2.5 Sqmm
7C x 2.5 Sqmm
4C x 16 Sqmm
4C x 6 Sqmm
3C x 10 Sqmm
3C x 4 Sqmm
3C x 2.5 Sqmm
SUPPLY OF FIBRE OPTICS CABLES
6 Fibre, Unitube, Single mode 9/125 µm, Flame retardant Low smoke, Galvanised steel wire armoured Fibre Optic Cable
LAYING / INSTALLATION, TESTING AND COMMISSIONING OF HV POWER CABLE, MV/LV POWER CABLES, CONTROL CABLES, FIBRE OPTIC CABLES
Laying / Installation, Testing & Commissioning of HV/MV/LV Power, Control Cables. Horizontal & vertical laying of cables of different voltage grade and types in ready trench/trays/Racks, underground/buried, supported on structures, through pipe sleeves, clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm), Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & GI Clamps, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Contractor shall provide necessary assistance for CEA approval, if required.
Laying / Installation, Testing and Commissioning of 11kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables of following sizes as per the attached drawings of this tender and directions of Engineer-in-Charge.
3C x 300 Sqmm
3C x 240 Sqmm
3C x 185 Sqmm
Laying / Installation, Testing and Commissioning of 6.6KV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables of following sizes as per the attached drawings of this tender and directions of Engineer-in-Charge.
3C x 120 Sqmm
Laying / Installation, Testing and Commissioning of 1.1 kV Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables of following sizes as per the attached drawings of this tender and directions of Engineer-in-Charge.
1C x 630 Sqmm
3.5C x 300 Sqmm
3.5C x 240 Sqmm
3C x 95 Sqmm
3.5C x 50 Sqmm
Laying / Installation, Testing and Commissioning of 1.1 kV Grade, CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables / control cables of following sizes as per the attached drawings of this tender and directions of Engineer-in-Charge.
14C x 2.5 Sqmm
7C x 2.5 Sqmm
4C x 16 Sqmm
4C x 6 Sqmm
3C x 10 Sqmm
3C x 4 Sqmm
3C x 2.5 Sqmm
Laying / Installation, Testing and Commissioning of Fibre Optics Cables
6 Fibre, Unitube, Single mode 9/125 µm, Flame retardant Low smoke, Galvanised steel wire armoured Fibre Optic Cable
HV CABLES END TERMINATION
Termination of XLPE insulated, HV cables (including supply of suitable Termination Kit) of following Cable sizes, including cutting stripping of cable insulation, fixing compression type lugs and crimping on to the cable, executing termination using termination kit (Heat Shrinkable/ Push-on type) restoration of the insulation, clamping, including anti tracking compound, ferrules, clamps, Aluminium tags, tagging and earthing of armour, installation & supply of PVC shrouds and PVC Hoods of required size for outdoor terminations including all labour and materials complete as per approved drawings, specification of this tender and direction of Engineer-in-charge. This will also include provision of additional supports if required, for proper dressing and support of cable. The contractor to also arrange suitable Stop Plugs for unused entry, if required. The cost for supply of suitable cable lugs shall be included in termination, no separate payment shall be made for cable lugs. All supplied lugs shall be of heavy duty long barrel type.
11kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
3C x 300 Sqmm - Indoor Termination Kit
3C x 240 Sqmm - Indoor Termination Kit
3C x 185 Sqmm - Indoor Termination Kit
6.6kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
3C x 120 Sqmm - Indoor Termination Kit
MV / LV CABLES END TERMINATION INCLUDING SUPPLY OF CRIMPING TYPE, HEAVY DUTY, BARREL TYPE ALLUMINIUM / COPPER LUGS
Termination of XLPE insulated armoured cables upto 1100 V grade and connection of leads cutting stripping of cable insulation, fixing of cable gland, crimping the lug on to the conductor, clamping of the cable cores, supply, fixing & marking with wire number ferrules etc. all necessary consumables and GI hardware, supply & installation of PVC shrouds for outdoor terminations including all labour and materials complete as per approved drawings, directions, of Engineer-in-charge. This will also include provision of additional supports, if required, for proper dressing and support of cables. The cost for supply of suitable crimping type, heavy duty, long barrel type Alluminium / Copper lugs shall be included in termination. No separate payment shall be made for cable lugs. All supplied lugs shall be of heavy duty long barrel type.
1.1 kV Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
1C x 630 Sqmm
3.5C x 300 Sqmm
3.5C x 240 Sqmm
3C x 95 Sqmm
3.5C x 50 Sqmm
1.1 kV Grade, Cu conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables / control cables
14C x 2.5 Sqmm
7C x 2.5 Sqmm
4C x 16 Sqmm
4C x 6 Sqmm
3C x 10 Sqmm
3C x 4 Sqmm
3C x 2.5 Sqmm
FIBRE OPTICS CABLES
6 Fibre, Unitube, Single mode 9/125 µm, Flame retardant Low smoke, Galvanised steel wire armoured Fibre Optic Cable
STRAIGHT THROUGH JOINTING FOR HV AND MV CABLES
Making of straight through joints (Outdoor OR Indoor as applicable) for XLPE insulated, armoured HT cables (including supply of straight through jointing kits and accessories as per relevant IS standards), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge, for the following sizes:
11kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
3C x 300 Sqmm
3C x 240 Sqmm
3C x 185 Sqmm
6.6kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
3C x 120 Sqmm
Making of straight through joints for XLPE insulated, armoured LT cables (including supply of straight through joint and accessories as per relevant IS standards), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge, for the following sizes:
1.1 kV Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
1C x 630 Sqmm
3.5C x 300 Sqmm
3.5C x 240 Sqmm
3C x 95 Sqmm
3.5C x 50 Sqmm
CABLE MARKERS
Supply and installation of cable markers for buried HV/MV cable at the interval of 30M, at every bend & at every cable joint location, supply of associated materials including engraving "BURIED ELECTRIC CABLES HT/LT" complete with support and foundation, painting as per approved drawing, specification of this tender and directions of Engineer-in-charge.
SUPPLY OF WEATHERPROOF AND FLAMEPROOF CABLE GLANDS
Supply of double compression Nickel plated brass cable gland suitable for Aluminium / Copper Armoured cable for following size:
11kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
Weather Proof Cable Gland for 3C x 300 Sqmm
Weather Proof Cable Gland for 3C x 240 Sqmm
Weather Proof Cable Gland for 3C x 185 Sqmm
Flame Proof Cable Gland for 3C x 300 Sqmm
Flame Proof Cable Gland for 3C x 240 Sqmm
Flame Proof Cable Gland for 3C x 185 Sqmm
6.6kV (UE) Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
Flame Proof Cable Gland for 3C x 120 Sqmm
Weather Proof Cable Gland for 3C x 120 Sqmm
1.1 kV Grade, Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables
Weather Proof Cable Gland for 1C x 630 Sqmm
Weather Proof Cable Gland for 3.5C x 300 Sqmm
Weather Proof Cable Gland for 3.5C x 240 Sqmm
Weather Proof Cable Gland for 3C x 95 Sqmm
Weather Proof Cable Gland for 3.5C x 50 Sqmm
Flame Proof Cable Gland for 1C x 630 Sqmm
Flame Proof Cable Gland for 3.5C x 300 Sqmm
Flame Proof Cable Gland for 3.5C x 240 Sqmm
Flame Proof Cable Gland for 3C x 95 Sqmm
Flame Proof Cable Gland for 3.5C x 50 Sqmm
1.1 kV Grade, Cu conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cables / control cables
Weather Proof Cable Gland for 14C x 2.5 Sqmm
Weather Proof Cable Gland for 7C x 2.5 Sqmm
Weather Proof Cable Gland for 4C x 16 Sqmm
Weather Proof Cable Gland for 4C x 6 Sqmm
Weather Proof Cable Gland for 3C x 10 Sqmm
Weather Proof Cable Gland for 3C x 4 Sqmm
Weather Proof Cable Gland for 3C x 2.5 Sqmm
Flame Proof Cable Gland for 14C x 2.5 Sqmm
Flame Proof Cable Gland for 7C x 2.5 Sqmm
Flame Proof Cable Gland for 4C x 16 Sqmm
Flame Proof Cable Gland for 4C x 6 Sqmm
Flame Proof Cable Gland for 3C x 10 Sqmm
Flame Proof Cable Gland for 3C x 4 Sqmm
Flame Proof Cable Gland for 3C x 2.5 Sqmm
CABLE TRAYS, TRAY COVERS AND ACCESSORIES
SUPPLY OF CABLE TRAYS, TRAY COVERS AND ACCESSORIES
SUPPLY OF STRAIGHT ELEMENT, TRAY COVER FOR STRAIGHT ELEMENT
300mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
600mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
300mm width,(100mm side rail, 3 meter long) 3 mm thick, Galvanised Steel & perforated type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
300mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
600mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
SUPPLY OF HORIZONTAL BENDS WITH BEND ANGLE 90 DEGREE AND TRAY COVER FOR HORIZONTAL BENDS WITH BEND ANGLE 90 DEGREE
Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 600 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 300 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
SUPPLY OF VERTICAL ELBOW-INSIDE RISER AND COVERS FOR VERTICAL ELBOW-INSIDE RISER
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- inside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- inside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- inside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- inside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
SUPPLY OF VERTICAL ELBOW-OUTSIDE RISER AND COVERS FOR VERTICAL ELBOW-OUTSIDE RISER
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- outside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- outside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- outside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- outside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
SUPPLY OF TEES AND COVERS FOR TEES
Hot Dipped Galvanized ladder type Tee, width 600 mm, height 100mm, radius 1200mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized ladder type Tee, width 300 mm, height 100mm, radius 1200mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 3 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized ladder type Tee, width 600 mm, radius 1200mm, with bolts, nuts, washers complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 3 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized ladder type Tee, width 300 mm, radius 1200mm, with bolts, nuts, washers complete with 2 sets of cover clamp, complete with accessories & hardwares
SUPPLY OF HORIZONTAL ADJUSTABLE COUPLER
Hot Dipped Galvanized type Horizontal Adjustable Coupler, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized type Horizontal Adjustable Coupler, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
SUPPLY OF VERTICAL ADJUSTABLE COUPLER
Hot Dipped Galvanized type Vertical Adjustable Coupler, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized type Vertical Adjustable Coupler, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, nuts, washers and other necessary accessories.
INSTALLATION OF CABLE TRAYS, TRAY COVERS AND ACCESSORIES
INSTALLATION OF STRAIGHT ELEMENT, TRAY COVER FOR STRAIGHT ELEMENT
300mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
600mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
300mm width,(100mm side rail, 3 meter long) 3 mm thick, Galvanised Steel & perforated type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
300mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
600mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
INSTALLATION OF HORIZONTAL BENDS WITH BEND ANGLE 90 DEGREE AND TRAY COVER FOR HORIZONTAL BENDS WITH BEND ANGLE 90 DEGREE
Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 600 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Ladder type, Horizontal Bend of 90 degree, radius 1200mm, width 300 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
INSTALLATION OF VERTICAL ELBOW-INSIDE RISER AND COVERS FOR VERTICAL ELBOW-INSIDE RISER
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- inside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- inside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- inside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- inside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
INSTALLATION OF VERTICAL ELBOW-OUTSIDE RISER AND COVERS FOR VERTICAL ELBOW-OUTSIDE RISER
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- outside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized Steel Ladder type, Vertical elbow- outside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- outside riser of 90 degree, radius 1200mm, width 600 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 2 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized Steel Vertical elbow- outside riser of 90 degree, radius 1200mm, width 300 mm, height 100mm complete with 2 sets of cover clamp, complete with accessories & hardwares
INSTALLATION OF TEES AND COVERS FOR TEES
Hot Dipped Galvanized ladder type Tee, width 600 mm, height 100mm, radius 1200mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized ladder type Tee, width 300 mm, height 100mm, radius 1200mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Cover with 3 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized ladder type Tee, width 600 mm, radius 1200mm, with bolts, nuts, washers complete with 2 sets of cover clamp, complete with accessories & hardwares
Cover with 3 sets of cover clamps and its necessary hardware's suitable for Hot Dipped Galvanized ladder type Tee, width 300 mm, radius 1200mm, with bolts, nuts, washers complete with 2 sets of cover clamp, complete with accessories & hardwares
INSTALLATION OF HORIZONTAL ADJUSTABLE COUPLER
Hot Dipped Galvanized type Horizontal Adjustable Coupler, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized type Horizontal Adjustable Coupler, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
INSTALLATION OF VERTICAL ADJUSTABLE COUPLER
Hot Dipped Galvanized type Vertical Adjustable Coupler, width 600 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, bolts, nuts, washers and other necessary accessories.
Hot Dipped Galvanized type Vertical Adjustable Coupler, width 300 mm, height 100mm, along with coupler plates, bonding Jumpers for earthing, nuts, washers and other necessary accessories.
SUPPLY AND INSTALLATIONS OF EARTHING AND LIGHTNING PROTECTION MATERIALS
ELECTRICAL EARTH PITS
Supply, Installation, connection to main earth grid, testing and commissioning of earth pits in hard soil area complete with 100 mm dia & 3000 mm long GI pipe electrode with funnel, GI test link, earth bus, preparation of concrete chamber with Cast Iron (CI) cover as inspection chamber including excavation of earth pit, supply and filling salt/ coke/ charcoal layer, supply of civil material, back filling, numbering of pits, including all labour and materials as per standard drawing complete as per specification of this tender and directions of Engineer-in-charge.
Supply, Installation, connection to main earth grid, testing and commissioning of earth pits in hard soil area complete with 40 mm dia & 3000 mm long GI ROD electrode, GI test link, concrete chamber with Cast Iron (CI) cover as inspection chamber including excavation of earth pit. supply of civil material, back filling, numbering of pits, including all labour and materials as per standard drawing complete as per specification of this tender and directions of Engineer-in-charge.
Supply, Installation, connection to main earth grid, testing and commissioning of earth pits in hard soil area complete with 100 mm dia & 3000 mm long GI pipe electrode with Copper earth plate 600mm x 600mm x 3mm thick including accessories, enclosure with cover plate having locking arrangemen, concrete chamber with Cast Iron (CI) cover as inspection chamber including excavation of earth pit, supply and filling salt/ coke/ charcoal layer, supply of civil material, back filling, numbering of pits, including all labour and materials as per standard drawing complete as per specification of this tender and directions of Engineer-in-charge.
EARTH PIT MARKER
Supply, Casting and installation of earth pit markers for directly buried earth electrode including supply of cement and associated materials including engraving "BURIED EARTH ELECTRODE NO." complete with support & foundation, painting & supply of paint as per approved drawing, specification of this tender and directions of Engineer-in-charge.
EARTHING CONDUCTORS AND CONNECTIONS
Supply of following GI / CU earth conductors for main earth grid/earthing network
75 x 10 mm GI earth strip (Main Grid / Mat / Conductor)
50 x 10 mm GI earth strip
50 x 6 mm GI earth strip
25 x 6 mm GI earth strip
8 SWG GI Wire
10 SWG GI Wire
25 x 6 mm Cu earth strip
Laying, clamping and connecting of following GI / CU earth conductors for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
75 x 10 mm GI earth strip (Main Grid / Mat / Conductor)
50 x 10 mm GI earth strip
50 x 6 mm GI earth strip
25 x 6 mm GI earth strip
8 SWG GI Wire
10 SWG GI Wire
25 x 6 mm Cu earth strip
EARTH PLATE ( Supply & installation of earth plate is also in contractor's scope )
GI Earth Bus/ Plate (900 x 75 x 10mm THK.)
LIGHTING WORK
Lighting Work (Lighting High Mast )
New High Mast
Supply, Installation, earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire , testing and commissioning of lighting luminaires and other accessories suitable for outdoor installation. This shall include transportation from owner's issue point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any modifications required for proper commissioning of fixture. Following Site Conditions will be considered for design and installation of 30 meter heigh High Mast : ● Maximum Ambient temperature : 38 Deg C ● Minimum Ambient temperature : 5 Deg C ● Equipment design temperature : 40 Deg C ● Earthquake Design factor : (Code IS-1893 Zone-V/Site spectra whichever is governing), As per IS 1893,Seismic factor = 0.36 ● Wind speed : 50 meter / sec ● Site Altitude : 90 m above MSL ● Relative humidity : 85% at 3 Deg C ● Environmental conditions : Corrosive Industrial Environment / Extreme Moisture (Tropical Climate)
The High Mast shall be comply the flowing codes and standards as minimum, but not limited to the following : ●. PLG 7 High Masts for Lighting and CCTV ●. SANS 10225:2012 High Mast natural frequency calculation ●. IS 875 Part – 3 Wind Loading ●. IS 2062/ BS EN 10025 High Tensile Steel Sheets ●. IS 2062 Mild Steel ●. BS EN ISO 1461 Galvanization ●. IS 3459 / 2266 Stainless steel Wire rope ●. IS 9968 Part – 1 Trailing Cable ●. IS 12615 Motor ●. IP66, IK08, wind tunnel test on a specimen to establish the force coefficients of the 20-side polygon and the value received from the wind tunnel test is to be taken in design, The winches are to be type tested through reputed institutions like IIT as consultants.
30 Meter High Mast with 12x400W LED Lighting fixtures comprising of the following as a minimum : ● 30 Meter High Mast shaft in three sections suitable for required wind speed with raising / lowering system comprising of frame for luminaries carriage suitable to install 12 nos luminaries in symmetrical arrangement, SS Wire rope, trailing cable, motor, manual handle, junction box, lightning protections including lighting finile and all other accessories required for the complete installation of the High Mast. ● MS anchor Foundation bolts as per Civil drawing no : TP-1ZZZA-CV-COD-0007.01 along with nuts, washers, anchor plates and templates ● Non-integral flood light luminaries of 400W LED Fixtures with control gear boxes ● Two nos. aviation obstruction lights with 9W LED Lamps ● Outdoor stand mounted flameproof MCB DB/ flameproof Feeder pillar distribution box with Incomer / outgoing MCB, ELCB, timers suitable for Zone 2 gas group IIA/IIB, Temp. Class T3. ● Trailing cables, wires as required (except the incoming power cables to Feeder Pillar Box / MCB Distribution Box). ● Supply shall include commissioning spares as required (List shall be provided by bidder)
Mandatory spares parts / items for trouble free operation of above High Mast for period of four (4) years
Relocation of Existing High Mast shaft and replacing the existing fixtures with new LED light fixtures
Re-location and Re-Installation of Existing High Mast shaft including Feeder Pillar / MCB distribution box with earthing, lightning protections, glanding, termination of incoming and outgoing cables/ wires at luminaire and control gear box, testing and commissioning of lighting luminaires and other accessories. The scope includes supply, installation, testing and commissioning of new 9nos. 400W LED fixtures replacing the existing HPMV Light fixtures of the relocated High Mast with suitable control gear box. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any modifications required for proper commissioning of fixture. This shall include transportation from owner's existing point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge. This shall also include shifting & storing of existing 400W fixtures to owner's provided place.
Supply, Installation, testing & commissioning of Additional new 1x400W LED Fixtures in Existing High Mast, while Re-location and Re-Installation of Existing High Mast with feeder pillar box complete with earthing, glanding, termination. This includes supply, installation of New Arm in Luminaire Carriage Ring for installation of New 400W LED Fixtures
Replacing the existing fixtures with new LED light fixtures
Supply, installation, testing and commissioning of new 9nos, 400W LED Fixtures replacing the HPSV light fixtures of the existing High mast with suitable control gear with earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire and control gear box and other accessories. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any modifications required for proper commissioning of fixture. This shall include shifting & storing of existing 9 nos 400W fixtures to owner's provided place by contractor's own lifting & transporting arrangement, etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge.
Demolition of existing High mast
Demolition of existing High mast including the removal of Feeder Pillar / MCB distribution box, earthing, glanding, cables including associated foundations / structures, termination of Incoming and outgoing Cables/ wires at luminaire and control gear box and other accessories. This shall include shifting & storing of demolished high mast and the accessories to owner's provided place by contractor's own lifting & transporting arrangement, etc. as required, all labour and material complete and as per the directions of Engineer-in-charge.
Relocation of Existing High Mast shaft with existing LED light fixtures
Relocation / Shifting / Re-Installation of Existing High Mast including the existing LED fixtures, Feeder Pillar / MCB distribution box with earthing, lighting protections, glanding, termination of Incoming and outgoing Cables/ wires at luminaire and control gear box.
MCB DB/Feeder pillar distribution box for High Mast
Outdoor stand mounted flameproof MCB DB/ flameproof Feeder pillar distribution box including flame proof motor and associated accessories suitable for Zone 2 gas group IIA/IIB, Temp. Class T3, with Incomer / outgoing MCB, ELCB, timers for the above explained High Mast of 12 x 400W LED fixtures
Outdoor stand mounted weatherproof MCB DB/ weatherproof Feeder pillar distribution box with Incomer / outgoing MCB, ELCB, timers for the above explained High Mast of 12 x 400W LED fixtures
Lighting Work (Peripheral lighting around CSS,DG set, LV & HT Panel, FPB )
Supply of different type of lighting luminaires
2x20W LED industrial luminaire (Tube light) comprises of polycarbonate housing duly prewired Polycarbonate housing, transparent cover of polycarbonate material complete with lamp & accessories . IP65 enclosure protection, suitable for installation in Outdoor corrosive atmosphere such as oil refineries, acid plants, chemical plants etc. Suitable for Loop-in Loop-out connections, complete with cable gland for Incoming & outgoing cable
200W LED Floodlight Luminaire with required accessories
Installation, earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire and control gear box, testing and commissioning of different type of lighting luminaires (eg. Flood light, Ceiling / bracket or pole mounting etc. with LED lamps),with suitable lighting supports, junction box and other accessories suitable for outdoor installation. This shall include transportation from owner's issue point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge.
2x20W LED industrial luminaire (Tube light) comprises of polycarbonate housing duly prewired Polycarbonate housing, transparent cover of polycarbonate material complete with lamp & accessories . IP65 enclosure protection, suitable for installation in Outdoor corrosive atmosphere such as oil refineries, acid plants, chemical plants etc. Suitable for Loop-in Loop-out connections, complete with cable gland for Incoming & outgoing cable
200W LED Floodlight Luminaire with required accessories
SUPPLY & INSTALLATION OF INDOOOR / OUTDOOR LIGHTING PANEL
415V, TPN, 12 Way, 2.5mm thick CRCA sheet steel enclosure material, Timer controlled contactor operated automatic ON/OFF operation for outgoing MCB feeders for building peripheral lighting, enclosure protection IP42, suitable for indoor installation, Panel shall be supplied with cable gland for all incoming and outgoing feeders (additionally 6 nos dummy stopper plug of Nickel plated brass material for outgoing feeders). Incomer and outgoing feeders are as follows : Incomer feeder (One number) : 63A, 415V, 4P MCB, R,Y,B Indication Lamp Outgoing feeder (Twelve number) : 16A, 240V DP MCB with ELCB
415V, TPN, 18 Way, Polycarbonate enclosure material, Timer controlled contactor operated automatic ON/OFF operation for outgoing MCB feeders for outdoor lighting, IP55 with canopy, suitable for outdoor installation. Panel shall be supplied with cable gland for all incoming and outgoing feeders (additionally 6 nos dummy stopper plug of Nickel plated brass material for outgoing feeders). Incomer and outgoing feeders are as follows : Incomer feeder (One number) : 63A, 415V, 4P MCB, R,Y,B Indication Lamp Outgoing feeder (Nine number) : 32A, 415V, 4P MCB with ELCB + Outgoing feeder (Nine number) : 16A, 240V DP MCB with ELCB
SUPPLY AND INSTALLATION OF LIGHTING JUCTION BOX
Four (4) Way Lighting Junction Box with Poycarbonate / FRP enclosure material, IP66, Suitable for termination of one number incoming and three number outing cable size of 3Cx2.5/4/6 sq mm, cu conductor, armoured, XLPE insulated cables. JBs will be suitable for installation in outdoor corrosive atmosphere such as oil refineries, acid plants, chemical plants etc. This will inclusive of double compression Nickel plated brass cable gland for incoming and all outgoing cables, SS hardwares for mounting / installation.
Four (4) Way flame proof Lighting Junction Box with Diecast Aluminium enclosure material, IP66, Suitable for termination of one number incoming and three number outing cable size of 3Cx2.5/4/6 sq mm, cu conductor, armoured, XLPE insulated cables. JBs will be suitable for suitable installation in gas group IIA/IIB, Temp. Class T3. This will inclusive of double compression Nickel plated brass cable gland for incoming and all outgoing cables, SS hardwares for mounting / installation.
GI PIPE SLEEVES
Supply of following sizes of class B, GI pipes/ sleeves for cable protection
GI pipe 50 mm dia
GI pipe 100 mm dia
GI pipe 150 mm dia
Fabrication and installation of following sizes of class B, GI pipes/ sleeves for cable protection, fixed on steel, concrete or similar structure, in trenches, ready to be buried in concrete including cutting, bending, grinding, threading and similar works, supply & fixing of required GI fastners, clamps, small iron structures, spacers, cleats, plug, bushings, sealing compound/ material etc., cutting and remaking of concrete surface including supply of civil material, all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.
GI pipe 50 mm dia
GI pipe 100 mm dia
GI pipe 150 mm dia
INSTALLATION, TESTING, COMMISSIONING OF DG SET AND ASSOCIATED ACCESSORIES
Installation (Including transportation from owner's store to actual place of installation, Un-packing), Earthing, Testing, Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Diesel Generator Set including control panel including drilling of gland plates for cable gland fixing, plugging of unused cable entries etc. Including supply and application of grouting materials, foundation bolts, plugs for unused cable entries, hardware materials, touch up painting as required, wiring material & copper lugs for wiring. Complete with labour & materials, as per approved drawings and directions of Engineer-in-charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope.
910KVA, 415V, 0.8 pf, Diesel Generator Set including ACB Operated Control / Protection Panel (with AMF facility), fuel oil tank, exhaust ducts (if any) and all associated accessories
500KVA, 415V, 0.8 pf, Diesel Generator Set including ACB Operated Control / Protection Panel (with AMF facility), fuel oil tank, exhaust ducts (if any) and all associated accessories
250KVA, 415V, 0.8 pf, Diesel Generator Set including ACB Operated Control / Protection Panel (with AMF facility), fuel oil tank, exhaust ducts (if any) and all associated accessories
SUPPLY, FABRICATION, INSTALLATION OF STRUCTURAL MEMBERS
Supply, Fabrication and installation of various sizes steel for supports, brackets for miscellaneous electrical equipment, base frames, support for switchgear, supports for outdoor lighting fixtures, hangers, risers, clamps etc. for miscellaneous electrical equipment / items, cable and cable tray supports with rolled MS sections, pipes, plates, strip etc., including shot blasting, welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc. Including surface finish, painting with one coat of 60 micron DFT of inorganic zinc silicate primer, 1 coat of 100 micron Two pack Epoxy HB Poly amide cured, including breaking walls, floors etc. for structures as required, including supply of all G.I hardware materials, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-In-charge. Any item weighing up to 1 kg or less shall neither be measured nor paid.
OPERATION, MAINTENANCE AND MISCELLANEOUS ACTIVITIES
Operation & Maintenance of all Equipment under Construction power (including OWNER supplied DG sets) including supply of necessary consumables and replacement / changing of consumables, after completion of Works & Handover of Construction Power System and providing assistance for various miscellaneous activities not covered under Schedule of Rates (SOR) by deployment of skilled Authorised Engineer, Electrical Supervisor , Electrician , Helper for period of four (5) years after commissioning / handover to owner. Filling of fuel (diesel) to DG Sets will be in Contractor's scope of work under this Operation and Maintenance. Diesel will be supplied by OWNER. However, Diesel will be collected by contractor from a distance of approx. 2KM from site. Operation & Maintenance crew will be required round the clock on three shift basis. Following Crew shall be provided as minimum for Operation & maintenance with one vehicle (Bolero Camper) for round the clock:
Engineer (Engineer must be Authorised work Licensor of Electrical HTV/LV system for Asam State Electricity Board)
Electrical Supervisor (Electrical Supervisor must be Authorised work Licensor of Electrical HTV/LV system for Asam State Electricity Board)
Technician/ Electrician (Technician/ Electrician must be Authorised work Licensor of Electrical HTV/LV system for Asam State Electricity Board)
Helper
One vehicle (Bolero Camper) for round the clock for Operation and Maintenance of Construction Power Equipment
MISCELLANEOUS
Scope of work of following items includes earthing and supply of fixing hardware, whether specifically mentioned or not.
SAFETY EQUIPMENT
Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
CO2 Fire Extinguishers (5 kg)
First Aid Boxes
Sand bucket with stand and sand
Shock hazard charts complete with aluminium frame and glass printing with three (3) language ie. English, Hindi & Assamese.
Enamelled caution boards printing with three (3) language ie. English, Hindi & Assamese.
Supply and laying of 1000 mm wide safety insulating mats of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge
Insulating Rubber Mat suitable for 11 kV Voltage Grade
Insulating Rubber Mat suitable for 415V Voltage Grade
Supply of following items as per applicable latest Indian standards / CEA regulations
Rubber hand gloves suitable for 11 kV Voltage Grade
Electric shoes
Arc Suite
Discharge rod with earthing facility suitable for 11 kV Voltage Grade
Test instruments like, HT/LT Meggar, HT line tester, Tong tester, Insulation tester & Battery Impedance tester, Multimeter, Phase sequence meter, Lux level meter for illumination check
LETTERING AND STENCILING
Identification of Electrical Items wherever required including supply of approved colour of Paint/Paints , painting of tag number of Electrical equipments as specified in specification & by Engineer -In-Charge. Supply of various types of paints, primers, preparation of surfaces by manual, hand tool cleaning, power tool cleaning and application of primer and finish paints for equipments surfaces/concrete surfaces, identification (Equipment name) lettering, stenciling,colour bands, colour coding etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding at all elevations, various locations, labour, materials, tools & tackles, consumables, safety, PPE's, supervision, etc. to complete the work in all respect as per the Painting Specifications drawings, and direction & full satisfaction of owner's/engineer in charge for all types of equipment as specified in the Painting specifications:
Letter size-32 mm
Letter size -50mm
DISMANTLING ACTIVITIES
Removal / Dismantling of existing 11kV UE grade, Al Conductor, Armoured power cable of following sizes and shifting it to lay down area within plant premises as per instructions from engineer in charge. Supply of consumables tools and Contractor shall use suitable vehicles for transportation, loading/ unloading. The activities may contain minor civil works like excavation, chipping, removal & handling of structural steels used for electrical items
3C X 185 Sqmm, 3C X 240 Sqmm, 3C X 300 Sqmm
4C x 16 Sqmm
4C x 6 Sqmm
Removal of Cable Termination (including Gland removal) of 11kV UE grade, Al Conductor, Armoured cable of following sizes
3C X 185 Sqmm, 3C X 240 Sqmm, 3C X 300 Sqmm
4C x 16 Sqmm
4C x 6 Sqmm
SEALING COMPOUND
Supply and installation of water proof material for sealing cable entries inside the switchgear buildings, outside electrical equpment / panel termination (Like : motor termination, DG termination, HV Switchgear, etc termination) of reputed make and as per Site engineer recommendation
Supply and installation of fire proof material for sealing cable entries inside the switchgear buildings, outside electrical equpment / panel termination (Like : motor termination, DG termination, HV Switchgear, etc termination) of reputed make and as per Site engineer recommendation
Saturated Fine River Sand supply and Filling
DISMANTLING, REMOVAL, SHIFTING AND STORAGE ACTIVITIES
Dismantling / Removal of all electrical installations (equipment / items & accessories including foundations, structures, cables, cable trays), shifting, storage at OWNER's storage point within plant premises OR outside plant premises after completion of all Construction activities (Approximate after 4 - 5 years). However, Removal / Dismantling works, activities are not applicable for 11kV HV indoor switchgears (Panel tag no : HT-002, HT-003), lighting & small power panels installed inside 11kV Switchgear rooms and its associated cables, New and relocated High Masts and its foundation (as these equipment / items are part of permanent installation). This includes supply of consumables tools, suitable vehicles for transportation, loading / unloading facility.
Dismantling / Removal, shifting and storage of concrete foundation, supports for various Equipment under Construction Power Distribution
Dismantling / Removal shifting and storage of Structural steel / supports, supports for various Equipment under Construction Power Distribution
Removal / Dismantling shifting and storage of Various Voltage Grade Power Cables and Various sizes Cables and associated cable terminations under Construction Power Distribution
Removal / Dismantling shifting and storage of Various Sizes Cable Trays and accessories under Construction Power Distribution
Removal / Dismantling, shifting and storage of Various Electrical Equipment / items (11KV HV Switchgears, 415V MV Panels, 415V Feeder Pillar Boxes, DG Sets, Lighting Panels, Earthing Materials, etc) under Construction Power Distribution
CEIG / CEA / STATUTORY APPROVAL
Arranging CEIG / CEA / Statutory approvals for the entire electrical installation of the plant. Job includes arranging visit of officials, inspection. Preparation of drawings if any, liquidation of punch points by Inspectors, arranging Certificate & approvals all complete. The Base drawings as available with Owner shall be provided .(The prescribed fees for approvals & inspection if paid by Contractor shall be reimbursed by Owner against submission of Documentary Evidence).
Konstelec Engineers Pvt. Ltd.
M/s SterlingElectro Enterprises.P.Ltd
Techno Power Enterprises Private Limited
Pace Process Controls Pvt Ltd
Tuaman Engineering Limited
Jayanta Khaund
M/s SterlingElectro Enterprises.P.Ltd
Konstelec Engineers Pvt. Ltd.
Techno Power Enterprises Private Limited
Pace Process Controls Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .