Executive Engineer ED Kupwara
Office of the Executive Engineer ED Kupwara
Creation of 100KVA Sub-Station with HT/LT network at Dever Anderbugh Lolab under JJM
2024_PDD_262984_1
e-NIT 20 of 2024-25
Open Tender
Electrical Works
Turn-key
40 days
Dever Anderbuggh
Refer to SBD
2 documents required · 2 mandatory
₹500
Executive Engineer ED Kupwara
₹11,300
2 Dec 2024
1 Nov 2024
22 Nov 2024
5 Nov 2024
21 Nov 2024
5 Nov 2024
Amount
Supply , Carriage upto site , Erection ,testing & commissioning of 11/0.433kV, 100 KVA , 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Efficient Level-2, Al. wound , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. as per latest amendment 2021
Supply , Carriage upto site , Erection , Testing and Commissioning of Steel Tubular Poles 9 Mtr Long (410-SP-33) with Planting depth of 1/6 th of the height of Poles as per REC standard.
Supply , Carriage upto site , Erection , Testing and Commissioning of Steel Tubular Poles 8 Mtr Long (410-SP-15) with Planting depth of 1/6 th of the height of Poles as per REC standard.
Supply , Carriage upto site , Laying , stringing, tensioning and binding of 50 mm2 ACSR Conductor (Rabbit) , including joints by PG clamps wherever required as per REC standard.
Cement bottoming of S T Poles 9 Mtrs long in 1:2:4 mix, 0.5 cum/pole, muffing 20 cm above ground, including plaster and curing of concrete as per REC standard.
Cement bottoming of S T Poles 8 Mtrs long in 1:2:4 mix, 0.40 cum/pole, muffing 20 cm above ground, including plaster and curing of concrete as per REC standard.
Supply and Painting of poles with one coat of redoxide and two coats of Aluminium paint of standard quality including Marking of Poles
Supply , installation ,testing & commissioning of pole Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm as per REC standard.
Supply , installation ,testing & commissioning of GI X-Arms including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket as per REC standard.
Supply , installation ,testing & commissioning of GI “V’ cross-arm (75x40x40x6)mm with Pole Top Bracket including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket as per REC standard.
Supply , installation ,testing & commissioning of Iron GI Channel/Angle/Flat of sizes including clamps for Transformer Pad/G.I Channel Bedding ,L.A Set/G.O Set/Horn Gap as per specification enclosed in Drawing.( Refer Drawing)
Supply , installation ,testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type as per REC standard
Supply , installation ,testing & commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A confirming to ISI specification
Supply , installation ,testing & commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply , installation ,testing & commissioning of LT fuse set with connectors , LT insulators mounted on Angle Iron 65*65*mm frame as per Drawing enclosed.
Supply , installation ,testing & commissioning of --Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC standard.
Supply & fixing ,testing, commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per REC specification.
Supply , installation ,testing , commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mmas per REC specifications.
Supply & laying, testing ,commissioning of 185 mm² single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type
Supply and Fixing of LT Structure Single shackle set (Mukhi Type) as per REC standard.
Supply & fixing, testing ,commissioning of LT shackle Insulators 16KN as per REC specification.
Supply and Erection of Galvanized stay set complete with 50 x 8 mm stay clamps, guy insulators 02 nos, anchor plate (200 x 200 x 6 mm), nut bolts ,02 No turn buckle ,1.8 m long, 16 mm dia solid GS rod & 7/3.15 mm dia G.I stranded wire complete.
Supplying and Fixing of Danger Plates with clamps with writing in English and Regional Language
Supply and fixing of Anti-Climbing Device with Clamps
Supply , installation ,testing & commissioning of Sundry items like Aluminium lugs, Jumpers, binding Tape,
Supply & fixing of GI nuts and bolts of sizes
Supply , installation ,testing & commissioning of 3-Ø, 4-Wire Trivector Meter (Prodigy ) with suitable ring type CT 200 Amp as per Standard
Providing, Installation, Fabrication of Sign Board of dimensions 3ft' x 2ft', 2mm MS Painted Sheet indicating Name of the work, Name of Loaction/Block, Name of Scheme, Est. Cost, Year & Executing Agency:
TESLA ENGINEERING WORKS (BID ID -2246777)
IMTIYAZ CONSTRUCTIONS AND ELECTRICALS (BID ID -2247756)
M/S KHAN BROTHERS (BID ID -2244787)
ALFA ENGINEERING SERVICES (BID ID -2247108)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .