| 1 | L1₹2.1 CrAccepted-AOC A3 7 B NEW AKRA STATION ROAD BYE LANE 2 P O JAGANNATH NAGAR P S MAHESHTALA PIN CODE 700140 | 24 PARAGANAS SOUTH | WEST BENGAL | 700140 | ₹2.1 Cr | L1 | Accepted-AOC L1-LOWEST |
| 2 | L2₹2.1 CrRejected-Finance VILL LAKSHMINARAYANPUR P O BANSHRA P S CANNING DIST SOUTH 24 PARGANAS PIN 743363 | CANNING | SOUTH 24 PARGANAS | WEST BENGAL | 743363 | ₹2.1 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹2.1 CrRejected-Finance | ₹2.1 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹2.1 CrRejected-Finance | ₹2.1 Cr | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical VILL BARARANKUA P O BALISAI PURBA MEDINIPUR | BALISAI | PURBA MEDINIPUR | WEST BENGAL | - | - | Rejected-Technical Insufficient Electrical Credential. |
| Sl No | Description | Qty | Unit | SANDIP BOSE L4 | SUDIPTA GUHA L1 | SAI CONCERN L3 | RAJA CONSTRUCTION L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Total Amount | 1 | Nos | 2,14,48,171 ₹2.1 Cr | 2,08,25,918 ₹2.1 Cr | 2,12,61,957 ₹2.1 Cr | 2,11,65,414 ₹2.1 Cr |
Tender Value
Refer Docs
EMD Value
₹4.0 L
Closing Date
12 Dec 2025, 4:00 pmClosed
SUPERINTENDING ENGINEER, P.W.DTE.
Office of the Superintending Engineer, Kolkata Health Circle, P.W.Dte., 1st Floor, KIT Building, P-16, India Exchange Place Extension, Kolkata - 700 073
Ancillary works for proposed Mechanized Laundry Project within K.S. Roy TB Hospital, Kolkata during the year 2025-26. Civil, Internal Electrical and Pump , sewerage line connection work etc
2025_WBPWD_946547_1
WBPWD/SE/KHC/NIT-05/2025-2026
Open Tender
CIVIL AND ELECTRICAL WORKS
270 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹4.0 L
Yes
Office of the Superintending Engineer, K.H.C.
18 Mar 2026
12 Nov 2025
15 Dec 2025
12 Nov 2025
12 Dec 2025
21 Nov 2025
21 Nov 2025
BASIC RATE In Figures To be entered by the Bidder in Rs. P
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PART-A Construction of Double storied Electrical Sub Station, LT Room, Store and Office.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Bailing or pumping out water from foundation trenches.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor Pakur Variety 1:3:6 proportion
TOTAL AMOUNT Without Taxes in Rs. P
1st Floor
2nd Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m Tor steel/Mild Steel SAIL/ TATA/RINL Ground Floor
1st Floor
2nd Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
1st Floor
2nd Floor
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Labour for Chipping of concrete surface before taking up Plastering work.
125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor.
1st Floor
2nd Floor
Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor
1st Floor
2nd Floor
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 16 Kg./sq.mtr and above Ground Floor
1st Floor
2nd Floor
Extra for work in grill gate. For hanging and locking arrangements including supply of materials and labour complete.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 15 mm thick plaster Ground floor
1st Floor
2nd Floor
20 mm thick plaster Ground Floor
1st Floor
2nd Floor
With 1:4 cement mortar 10 mm thick plaster Ground Floor
1st Floor
2nd Floor
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety In Ground Floor Including roof
1st Floor
2nd Floor
3rd Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick) Ground Floor
1st Floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile above 0.09 Sq.m Coloured decorative Ground Floor
1st Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) Two Coats In Ground Floor Solvent based interior grade Acrylic Primer
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two coats Luxury Quality
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats Ground Floor
1st Floor
2nd Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion Ground Floor
1st Floor
2nd Floor
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). In 10-12 Micron thickness Annodizing film Natural white 2- track sliding window Bottom frame
Top and side frame.
Shutter for all track sliding window. Bottom & Top member
Style side member.
Interlock member.
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. 2 track sliding window. Ground Floor
1st Floor
2nd Floor
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. For sliding windows ' T' shaped EPDM gasket for frames.
U' shaped EPDM gasket for frames.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The qua
m round
Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 470 mm X 280 mm X 340 mm
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. Sink only 630 mm X 550 mm X 180 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) Single Socketed 3 Meter Length (b) 110 mm
(B) Fittings (iii) Door Tee (b) 110 mm
(x) Bend 87.5º (b) 110 mm
(xi) Door Bend (T.S.) (b) 110 mm
(xxi) 110 X 110 P Trap 75 mm
(xv) Vent Cowl (b) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground 110 mm dia.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes: 110 mm. Dia.
UPVC Fittings: Plain Tee 110 mm. Dia.
Shoe 110 mm. Dia.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. 1:3:6 proportion
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] With approved concrete pump In Ground Floor and Foundation
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m Tor steel/Mild Steel SAIL/ TATA/RINL
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Brick work with 1st class bricks in cement mortar (1:4) (a) In ground floor Foundation
Shoe 110 mm. Dia.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Bailing or pumping out water from foundation trenches.
Supplying Sal-bullah piles at work site, including dressing and making one end pointed 150mm diameter
Labour for driving Sal-bullah / Eucalyptus bullah piles by monkey in sorts of soil including hoisting and placing piles in position, protecting the pile head with iron ring and cutting and shaping heads before and after driving and including hire and labour for necessary driving appliances and all tackles. 150mm diameter
Brick work with 1st class bricks in cement mortar (1:4) (a) In ground floor Foundation
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. 1:3:6 proportion
3rd Floor
2nd Floor.
3rd Floor
3rd Floor
Supply & Installation of 5 HP / 6 stage submersible pump motor set. (Make:- Kirloskar / KSB)
Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor
3rd FLoor
Extra for work in grill gate. For hanging and locking arrangements including supply of materials and labour complete.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs Grill weighing above 16 Kg./sq.mtr and above In Ground Floor
Labour for Chipping of concrete surface before taking up Plastering work.
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
1st Floor
2nd Floor
3rd Floor
With 1:4 cement mortar 10 mm thick plaster Ground Floor
Supplying and fitting of 2.5 Sqmm 3 Core submersible flat cable
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety 1st Floor
1st Floor
2nd Floor
3rd Floor
1st Floor
2nd Floor
3rd Floor
Top and side frame.
Shutter for all track sliding window. Bottom & Top member
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding &casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). In 10-12 Micron thickness Annodizing film Natural white 3- track sliding window Bottom frame
Style side member
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
U' shaped EPDM gasket for frames.
Supplying maruti lock (100mm)
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. For sliding windows T' shaped EPDM gasket for frames.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick coloured / tinted / smoke glass.
Point
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) For Exposed Work 50 mm dia. medium quality
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) For Exposed Work PVC Pipes 50 mm dia
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 Compact Compact Ball Valve with SS Handle For CPVC/ UPVC Fittings 50 mm dia.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 5000 litre capacity
Supplying and fitting of 400v, 50 hz, MK-IFASD starter of relay range (9-14) Amp, (Make LT/LK)
UPVC Fittings: Plain Tee 110 mm. Dia.
Shoe 110 mm. Dia.
Shoe 110 mm. Dia.
PART-D Sinking of two deep tube wells 150 mm dia (200 mm dia top enlargement) along with other allied works.
PART-D Sinking of two deep tube wells 150 mm dia (200 mm dia top enlargement) along with other allied works.
Meter
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report
Each Test
Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge. 150 mm
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Supplying, fitting and fixing heavy type bell mouth reducing socket. 200 mm X 250 mm
Providing 200 mm centre guide. With Clamp
per Set
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). PVC Pipes (Dia) 50 mm
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application 150mm internal dia.
Metre
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation 1:3:6 proportion
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Do - by fine sand
astering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). With Pakur variety. (SAIL/TATA/RINL) 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. 1:3:6 proportion
Shoe 110 mm. Dia.
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. 100 mm dia.
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. 1:3:6 proportion
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] With approved concrete pump In Ground Floor and Foundation
TOTAL AMOUNT in Rs. P
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. 1:3:6 proportion
Labour for Chipping of concrete surface before taking up Plastering work.
TOTAL AMOUNT in Rs. P
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster Ground Floor.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. For roof truss works Span up to 12 Mtr 50mm X 50mm X 6mm
Welding in M.S. structural work with gas or electric Continuous weld.
Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised "C" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc. (The rate is exclusive of the cost of posts) 50 mm. x 50 mm. x 8 g.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above
Extra for work in grill gate. For hanging and locking arrangements including supply of materials and labour complete. (15% extra over the corresponding item of grill )
Shoe 110 mm. Dia.
Sheet1 in Rs. P
On steel or other metal surface With sup
er gloss (hi-gloss) Two coats (with any shade except white)
PART-H Widening and strengthening of compound road upto proposed Sub-station building.
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. Depth up to 150 mm.
Brick work with 1st class bricks in cement mortar (1:4) (a) In ground floor Foundation
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor Pakur Variety] 1:3:6 proportion
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make Extra for additional depth beyond 1.5 metre.
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D) 35 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size Cover: 700 mm X 100 mm Frame: 910 mm X 185 mm opening: 560mm Weight: 245 kg (approx)
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Internal Electrical Installation work.
al finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, as to GS. [Make: Legrand/ L&K/ABB] 6 way Enclosure.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment , 2+12 way Enclosure as to GS. [Make: Legrand/ L&K/ABB]
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection, as to GS. [Make: Legrand/ L&K/ABB] 415 V, 63A FP for PBDB
240 V, 40A DP for SPNDB
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection as to GS. [Make: Legrand/ L&K/ABB] 125A FP for VTPNDB
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as to GS. [Make: Legrand/ L&K/ABB] 6A - 32A SP MCB for PBDB & SPNDB
Distn. wiring in 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC in single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Make: RR Kabel/Finolex/Polycab/ Havells/ Mescab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Make- Legrand, Arteor/Myrius) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish., as to GS. a) On Board
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC.
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Make- Legrand, Arteor/Myrius) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make- Legrand, Arteor/Myrius) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9")
Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 23 cm Exhaust fan (9")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 38 cm Exhaust fan (15")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 38 cm Exhaust fan (15")
BoQ_Ver3.0
S & F Dual Timer Control Unit for Air Circulator & Exhaust Fan control at Substation assembled with following accessories: - i) 16-way SPNDB Box (Legrand/L & K)-1 no. ii) 25A DP MCB (Legrand/L & K)-1 no. iii)Digital 24 hour time switch (Make-GIC-67DDT0) -1no.
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.42 MB
WBF2911.pdf
Tender Documents • 1.86 MB
Bidders05.pdf
Additional Documents • 1.19 MB
BOQ_2251463.xls
BOQ • 0.76 MB
Download all tender documents and submit your bid