Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-Finance HNO 1131 TIVIM BARDEZ GOA | TIVIM | BARDEZ | GOA | 403507 | L1 | Accepted-Finance L1 | |
| 2 | L2₹17.0 L+₹27,095.28 (1.62%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹15.9 L
EMD Value
₹31,877
Closing Date
1 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
O/O EXECUTIVE ENGINEER, DIVN V, BICHOLIM.
Tender for the work for enhancement of 200KVA Vasantnagar Ground DTC to 400KVA DTC for APS to 2 nos of 3phase LTD service connection to Mr.Sayyad rajesh Sheikh and Rafik Rajesh Sheikh for total load of 12.04KW, in the Jurisdiction of SO Sankhali
2025_ED_26946_1
Tender-73/Div-V (2025-26)
Open Tender
Electrical Works
Percentage
180 days
Sankhali
AS PER APPROVED NIT
2 documents required · 2 mandatory
₹500
₹31,877
3 Feb 2026
26 Dec 2025
2 Jan 2026
27 Dec 2025
1 Jan 2026
29 Dec 2025
Cost of Material
Supply and Erection of GI Flat 25 x 5 mm
Supply erection, testing and commissioning of 400Kva 11/0.433KV delta star,copper wound, oil cooled outdoor type distribution transformer including plinth foundation and terminal boxes at both LV and HV sides.
Supply & Erection of LT/11KV stay set Complete 11Mts long RCC pole
Supply & Erection of Earthing complete with chamber as per drg/No. CEE/E-830. Each earthing should consist as follows a) 40mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia-0.2mtr e) Salt-20 kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr.
Supply & Erection of MS Distribution box along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement
Supply and laying of unarmoured 1core 300sqmm XLPE power cable
Supply & stringing of 3 ½ Core XLPE Armoured cable, 1.1KV Grade 185 mm²
Supply & Erection of Enamelled danger boards 11000 Volts,250mm x 200mm
Supply & Erection of Aluminium crimping Lugs shall as amended upto date. Lugs shall be made of aluminium of grade suitable for aluminium cable for sizes 300 Sq.mm.
Supply & Erection of DTC metering unit
RCC poles 7.5 mtr long
Stay set complete for 7.5mtr RCC Pole
HDGI L.T 4 pin cross Arm channel
HDGI 2 pin cross Arm channel
GI X arm clamps LA for 7.5mtrs RCC pole
LT Shackle Insulators with metal Part
G.I. Nuts & Bolts 100x16mm
ANT conductor
GNAT conductor
GI Tubular Fencing complete with gate & side dismantling system as per the specification for Distribution Transformer & feeder Pillars(Size4M X 3M X2M)with concreting for GI fencing supports with Plinth(0.3x0.3x0.5)Cu.mx12nos. Each ratio1:3:6 & brick masonary.
supply and spreading of 40/20mm basalyic or granitic stone aggregate in the switch yard
Civil Estimate For 400KVA Transformer foundation/Pinth
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas(exceeding 30 cm in depth,1.5 min width as well as 10 sq.mm on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading ,danger lighting guarding as directed in; All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundations complete.
providing & laying cement concrete 1:3:6 ( 1 cement : 3 coarse sand:6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering , shuttering and finishing in:all works upto plinth level
providing and laying in position (1:11/2:3) reinforced cement concrete excluding the cost of centering shuttering,finishing and reinfrocement (1 cement:1 1/2 coarse sand :3 graded stone agg 20 mm nominal size)All works upto plinth level
providing TMT steel reinforcement bars of (SAIL,TATA,VIZAG, JSW Steel Ltd.) (confirming to IS 1786 of 1986) for RCC work (conforming to I.S.1786 of 1986) including bending , binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
centering & shuttering including strutting ,propping & removal of forms for:vertical surfaces such as retaining walls, return walls, partitions,walls(any thickness)including attached pilasters,Buttresses,plinth and string courses, fillets and the like
12mm cement plaster 1:4 (1 cement: 4 fine sand)
Refilling the pipeline /foundation trenches plinth sides ,foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 m and all lifts and disposal of surplus earth as directed by engineer in charge.
Cost of Erection
Supply and Erection of GI Flat 25 x 5 mm
Supply erection, testing and commissioning of 400Kva 11/0.433KV delta star,copper wound, oil cooled outdoor type distribution transformer including plinth foundation and terminal boxes at both LV and HV sides.
Removing of 200KVA 11/0.433KV 3 phase outdoor type, Oil immeresed Aluminium wound level II distribution transformers
Supply & Erection of LT/11KV stay set Complete 11Mts long RCC pole
Removing of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced WEASEL 6/1/2.59 (nominal aluminium area 30 sq. mm.) (139 amp max at 45 degree C) for line
Supply & Erection of Earthing complete with chamber as per drg/No. CEE/E-830. Each earthing should consist as follows a) 40mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia-0.2mtr e) Salt-20 kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr.
Supply & Erection of MS Distribution box along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement
Supply and laying of unarmoured 1core 300sqmm XLPE power cable
Supply & stringing of 3 ½ Core XLPE Armoured cable, 1.1KV Grade 185 mm²
Supply & Erection of Aluminium crimping Lugs shall as amended upto date. Lugs shall be made of aluminium of grade suitable for aluminium cable for sizes 300 Sq.mm.
Supply & Erection of DTC metering unit
Removing of 11KV GOAB switch 200 A, 3 Pole DP AB Switch
Removing of 11KV 200 A H.G Fuse unit
Removing of HDGI structural material
Removing of MS Distribution Box
Removing of 3 ½ Core XLPE Armoured cable,240sq mm 1.1KV grade
RCC poles 7.5 mtr long
Stay set complete for 7.5mtr RCC Pole
HDGI L.T 4 pin cross Arm channel
HDGI 2 pin cross Arm channel
LT Shackle Insulators with metal Part
Cement concrete for MS distribution Box foundation
ANT conductor
GNAT conductor
Removing &restringing ANT conductor
Removing &restringing GNAT conductor
Removing of RCC pole 11.00 mtr long
GI Tubular Fencing complete with gate & side dismantling system as per the specification for Distribution Transformer & feeder Pillars(Size4M X 3M X2M)with concreting for GI fencing supports with Plinth(0.3x0.3x0.5)Cu.mx12nos. Each ratio1:3:6 & brick masonary.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 23.80 MB
BOQ_27397.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .