Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | L1 | Accepted-AOC Accepted due to successful L-1 bidder for the work | |
| 2 | L2₹22,426−₹1.8 L (88.7%)Rejected-Finance AT PO DANARA TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L2 | Rejected-Finance Rejected due to L2 Bidder | |
| 3 | L3₹2.9 L+₹93,739.11 (47.1%)Rejected-Finance AT PO KALAMUCHHIN PS COLLIERY TALCHER DIST ANGUL PIN 759103 ODISHA | TALCHER | ANGUL | ODISHA | 759103 | L3 | Rejected-Finance Rejected due to L3 Bidder |
Tender Value
₹3.2 L
EMD Value
₹4,100
Closing Date
19 Dec 2023, 4:00 pmClosed
Sri P R Mohapatra SO(EnM) CWS(X) Talcher.
Southbalanda, Angul,Odisha. email so-enm-cwst.mcl(at)coalindia.in , Mb no. 9438877985
Maintenance of 11KV HT and 440VLT Overhead lines of CWS Talcher catering power from 33/11KV Central substation Balanda to 2X1MVA,11/0.440KV main substation, A and C type colony substations (500KVA,11/0.415KV) of CWS(X), Talcher for period of one year
2023_MCL_295535_1
MCL/GM/CWST/EnM/SS/23-24/37 DT. 07.12.2023
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
CWS Talcher
As per NIT documents
4 documents required · 4 mandatory
₹4,100
5 Jan 2024
7 Dec 2023
20 Dec 2023
8 Dec 2023
19 Dec 2023
8 Dec 2023
8 Dec 2023 - 12 Dec 2023
Amount
Item Description/ Heading
Maintenance of 11 KV/440V Overhead line of E&M department catering power from 33/11 kv Central substation to 2x1 MVA main substation followed by A & C type colony substation CWS(x), Talcher. (one lineman/ pole rider and one helper required)
Supply of galvanized stay set for 11KV overheard lines complete with 19/20 mm dia X 1.8 mtr long saty rod,anchor plate of size 45cmX 45cmX7.5mm thick,thimble,stayclamps, turn buckle(20mmX600mm),7/4.00mm dia G.I. stay wire and 11KV strain insulator etc in cement concrete 1:3:6(1 cement:3coarse sand:6 grade stone aggregate 40mm nominal size)foundation including excavation and refilling etc. as required
Supply of three piece non linear resistor type lightining resistor suitable for 3 wire,11KV O/H lines with rated voltage KV (rms) with a nominal discharge current rating 5KA and complete eith galvanised clamping arrngement.G.I bolts ,nuts ,washers etc.as reqd
Supply of 33KV pin Insulator complete with large steel head G.I. pin ,nuts,washers etc.as required. MCL SOR E&M Works 2023 -2648)
Supply of 11KV disc Insulator for 11 kv over head lineswith galvanised insulator fittings, ball & socket type & complete with galvanised strain clamps, bolts, nuts & washers etc.as required. MCL SOR E&M Works 2023 -2646/2647)
Erection of steel tubular or rail pole strut in cement concrete 1:3:6(1cement:3 coarse sand:6 stone aggregate 40mm nominal size) foundation including excavation & refilling & secured with holding clamps,bolts,nuts,etc.as required. MCL SOR E&M Works 2023 - 11.4
Supplying and making straight through cable jointing with heat shrinkable jointing kit complet with all assesories including ferrules suitable for 120 SQmm size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.MCL SOR E&M Works 2023 ,10.6.2)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
Sachin Kumar Pradhan
TRISHAKTI ENGINEERING
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_306108.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .