Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹38.6 L+₹5.7 L (17.4%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹41.9 L+₹9.0 L (27.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹44.7 L+₹11.8 L (35.9%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
1 Mar 2021, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Repairs / Replaceplace of worn out pipe line of external water supply distribustion system at AGE B/R-II area under GE (N) Ahmednagar
2021_MES_417911_1
8499 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹76,000
Yes
9 Mar 2021
2 Feb 2021
3 Mar 2021
2 Feb 2021
1 Mar 2021
16 Feb 2021
Amount
Excavation in trenches n' exc 1.5 m wide and n' exc 1.5 m in depth and n' exc 10 Sq m on plan and getting out in Soft / loose soil etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 1 (here-in-before) but in Hard / dense soil
Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm etc complete all as specified and directed by Engineer-in-Charge
Removing excavated material to a distance n' exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Taking up cast iron / ductile iron water mains with spigot and socket ends having lead / tyton joints including all fittings and burning out joints, removing lead for 80 bore of pipes etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 5 (here-in-before) but 100 mm bore pipe
All as per serial item No 5 (here-in-before) but 150 mm bore pipe
All as per serial item No 5 (here-in-before) but 200 mm bore pipe
All as per serial item No 5 (here-in-before) but 250 mm bore pipe
All as per serial item No 5 (here-in-before) but 300 mm bore pipe. NOTE for item Nos 5 to 10 : Earth work & excavation shall be measured and paid separately. (i) The contractor/his supervisor will report the office on 09.00 clock morning every day to collect the complaints from JE and will render the completion within 12 hours failing which 500 Rupees per day per complaint will be charged as an penalty & the same will be recovered from contractor's dues (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which 500 Rupees per day per complaint will be charged as penalty .
Supply and laying cast iron / ductile iron pipes with spigot and socket ends centrifugally cast, Class LA / K-9 , in any length, laid in trenches for 80 mm bore pipes complete all as etc complete all as specified and directed by Engineer-in-Charge Note: Lead Joints shall be measured and paid separately. Tyton joints required are deemed to be included in the unit rate quoted.
All as per serial item No 11 (here-in-before) but using old retrieved pipe from srl item No 5 with new tyton joints.
All as per serial item No 11 (here-in-before) but 100 mm bore pipe
All as per serial item No 11 (here-in-before) but using old retrieved pipe from srl item No 6 with new tyton joints.
All as per serial item No 11 (here-in-before) but 150 mm bore pipe
All as per serial item No 11 (here-in-before) but using old retrieved pipe from srl item No 7 with new tyton joints.
All as per serial item No 11 (here-in-before) but 200 mm bore pipe
All as per serial item No 11 (here-in-before) but using old retrieved pipe from srl item No 8 with new tyton joints.
All as per serial item No 11 (here-in-before) but 250 mm bore pipe
All as per serial item No 11 (here-in-befoe) but using old retrieved pipe from srl item No 9 with new tyton joints.
All as per serial item No 11 (here-in-before) but 300 mm bore pipe
All as per serial item No 11 (here-in-before) but using old retrieved pipe from srl item No 10 with new tyton joints. NOTE for items 11 to 22 : (i) Earth work & excavation has already been considered. (ii) Lead Joints shall be measured and paid separately. (iii) Tyton joints required are deemed to be included in the quoted rates. (iv)Earth work & excavation shall be measured and paid separately & Earth work & excavation shall be manual or with mechanical equipments such as pockland, JCB etc, (v) The contractor/his supervisor will report the office on 09.00 clock morning every day to collect the complaints from JE and will render the completion within 12 hours failing which Rs 500 per day will be charged as an penalty & the same will be recovered from contractor's dues (vi). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which 500 Rupees per day charged as penalty per complaints
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for 100 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for 80 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 23 (here-in-before) but 50 mm bore pipe
All as per serial item No 23 (here-in-before) but 40 mm bore pipe
All as per serial item No 23 (here-in-before) but 25mm bore pipe
All as per serial item No 23 (here-in-before) but 20 mm bore pipe
All as per serial item No 23 (here-in-before) but 15 mm bore pipe NOTE for item Nos 23 to 29 : Earth work & excavation shall be measured and paid separately & Earth work & excavation shall be manual or with mechanical equipments such as pockland, JCB etc, (i) The contractor/his supervisor will report the office on 09.00 clock morning every day to collect the complaints from JE and will render the completion within 12 hours failing which Rs 500 per day per complaints will be charged as an penalty & the same will be recovered from contractor. (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which Rs 500 per day per completent will be charged as penalty and the same will be recovered from contractors dues.
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for the 100 bore pipe etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 30 (here-in-before) but 80 mm bore pipe
All as per serial item No 30 (here-in-before) but 50 mm bore pipe
All as per serial item No 30 (here-in-before) but 40 mm bore pipe
All as per serial item No 30 (here-in-before) but 25mm bore pipe
All as per serial item No 30 (here-in-before) but 20 mm bore pipe
All as per serial item No 30 (here-in-before) but 15 mm bore pipe
All as per serial item No 30 (here-in-before) but using old retrieved pipe from srl item No 23 with new GI fittings.
All as per serial item No 31 (here-in-before) but using old retrieved pipe from srl item No 24 with new GI fittings.
All as per serial item No 32 (here-in-before) but using old retrieved pipe from srl item No 25 with new GI fittings.
All as per serial item No 33 (here-in-before) but using old retrieved pipe from srl item No 26 ,with new GI fittings.
All as per serial item No 34 (here-in-before) but using old retrieved pipe from srl item No 27,with new GI fittings.
All as per serial item No 35 (here-in-before) but using old retrieved pipe from srl item No 28 ,with new GI fittings.
All as per serial item No 36 (here-in-before) but using old retrieved pipe from srl item No 29 ,with new GI fittings. NOTE for item Nos 30 to 43 : Earth work & excavation has already been considered under srl item Nos 5 to 11. (i) The contractor/his supervisor will report the office on 09.00 clock morning every day to collect the complaints from JE and will render the completion within 12 hours failing which 500 Rupees per day will be charged as an penalty & the same will be recovered from contractor. (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which 500 Rupees per day charged as penalty .
Opening of unserviceable sluice valves, cleaning the serviceable parts, adjusting of moving parts , greasing , re-assembling of valve and fixing to the desired position with and including replacement of rubber gaskets, nuts ,bolts, washers , gland packing,Brass Checknuts and SS Spindle suitable for 80 mm bore valve etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 44 (here-in-before) but 100 mm bore pipe
All as per serial item No 44 (here-in-before) but 150 mm bore pipe
All as per serial item No 44 (here-in-before) but 200 mm bore pipe
All as per serial item No 44 (here-in-before) but 250 mm bore pipe
All as per serial item No 44 (here-in-before) but 300 mm bore pipe
Supply and fix in repairs cast iron sluice valve ,80 mm bore , Class PN1, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 50 (here-in-befor3) but 100 mm bore pipe
All as per serial item No 50 (here-in-before) but 150 mm bore pipe
All as per serial item No 50 (here-in-before) but 200 mm bore pipe
All as per serial item No 50 (here-in-before) but 250 mm bore pipe
All as per serial item No 50 (here-in-before) but 300 mm bore pipe
Material and labour for run lead joints in old /new pipes / specials for 80 mm bore pipes etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 56 (here-in-before) but 100 mm bore pipe
All as per serial item No 56 (here-in-before) but 150 mm bore pipe
All as per serial item No 56 (here-in-before) but 200 mm bore pipe
All as per serial item No 56 (here-in-before) but 250 mm bore pipe
All as per serial item No 56 (here-in-before) but 300 mm bore pipe NOTE for items 56 to 61 : Earth work & excavation has already been considered.
Repairs/rectification of GI Pipe leakage by replacing short piece length up to 0.50 m in wall/floors etc and excavation upto 1 cum as in trenches and including providing unions, reducers,nipples etc for 15 mm bore pipe and making necessary connections to make it functional etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 62 (here-in-before) but 20 mm bore pipe
All as per serial item No 62 (here-in-before) but 25 mm bore pipe
All as per serial item No 62 (here-in-before) but 40 mm bore pipe
All as per serial item No 62 (here-in-before) but 50 mm bore pipe
Material and labour for Caulking lead joints including run lead for arresting the leakages for 80mm bore pipes etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 67 (here-in-before) but 100 mm bore pipe
All as per serial item No 67 (here-in-before) but 150 mm bore pipe
All as per serial item No 67 (here-in-before) but 200 mm bore pipe
All as per serial item No 67 (here-in-before) but 250 mm bore pipe
All as per serial item No 67 (here-in-before) but 300 mm bore pipe NOTE for items 61 to 72 : Earth work & excavation has already been considered. (v) The contractor/his supervisor will report the office on 09.00 clock morning every day to collect the complaints from JE and will render the completion within 12 hours failing which 500 Rupees per day will be charged as an penalty & the same will be recovered from contractor. (vi). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which 500 Rupees per day charged as penalty .
Supply and fixing in repairs of graphite gland packing for sluice valve 80 mm bore etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 73 (here-in-before) but 100 mm bore pipe
All as per serial item No 73 (here-in-before) but 150 mm bore pipe
All as per serial item No 73 (here-in-before) but 200 mm bore pipe
All as per serial item No 73 (here-in-before) but 250 mm bore pipe
All as per serial item No 73 (here-in-before) but 300 mm bore pipe. NOTE for items 73 to 78 : Glands packing shall be provided to the valve other than considered under srl item Nos 49 to 54
Supply and fixing in repairs mechanical joints, non extendable type with rings, nuts , bolts & washers etc for 80 mm bore CI / DI pipes etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 79 (here-in-before) but 100 mm bore pipe
All as per serial item No 79 (here-in-before) but 150 mm bore pipe
All as per serial item No 79 (here-in-before) but 200 mm bore pipe
All as per serial item No 79 (here-in-before) but 250 mm bore pipe
All as per serial item No 79 (here-in-before) but 300 mm bore pipe
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for up to 50 mm bore GI pipe etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 85 (here-in-before) but 40 mm bore pipe
All as per serial item No 85 (here-in-before) but 25 mm bore pipe
All as per serial item No 85 (here-in-before) but 20 mm bore pipe
All as per serial item No 85 (here-in-before) but 15 mm bore pipe NOTE for srl item 85 to 89:Make:ZOLOTO/BIR/LEADER
Dismantaling old valve chamber & M & L for Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : Note : Quoted rate include the following :- (a) 100 mm thick hard core, (b) PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in cement and sand mortar (1:6), (d) 15 mm internal and external plaster in cement and sand mortar (1:4), (e)3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangments.
(a) 1500 mm x 1200 mm x 1000 mm
(a) 1500 mm x 1100 mm x 1000 mm
(a) 1500 mm x 1000 mm x 1000 mm
Drilling and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 20 to 50 mm etc complete all as specified and directed by Engineer-in-Charge
Taking up or Down PVC tubing and connections from trenches /walls/floors etc cleaning for 80mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Taking up or Down PVC tubing and connections from trenches /walls/floors etc cleaning for 100mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Taking up or Down PVC tubing and connections from trenches /walls/floors etc cleaning for 150mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs of PVC pipe of size 80 mm heavy duty, 4 Kg / Sqcm pressure including necessary fittings etc complete all as specified and directed by Engineer-in-Charge:-
All as per Sl item No 95 (here-in-before) but for 100 mm
All as per Sl item No 95 (here-in-before) but for 150 mm Note for item Nos 98 to 100 : Earth work & excavation shall be measured and paid separately.
Supply & fixing in replacement of CI foot valves of size 80 mm etc complete all as specified and directed by Engineer-in-Charge
Material and labour for cast iron / ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm more pipes etc complete all as specified and directed by Engineer-in-Charge
Cutting cast iron / ductile iron pipes in position for taking out branch connection by inserting new tee etc for 80 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
All as per Sl item No 103 (here-in-before) but for 100 mm
All as per Sl item No 103 (here-in-before) but for 150 mm
All as per Sl item No 103 (here-in-before) but for 200 mm
All as per Sl item No 103 (here-in-before) but for 250 mm
All as per Sl item No 103 (here-in-before) but for 300 mm
Supply & Fixing in repair /replacement including stainer for CI / DI pipe of size 80mm etc complete all as specified and directed by Engineer-in-Charge Make: Capstan/woltman/kirloskar
Supply & Fixing in repair /replacement including stainer for CI / DI pipe of size 100mm etc complete all as specified and directed by Engineer-in-Charge. Make: Capstan/woltman/kirloskar
Supply & Fixing in repair /replacement including stainer for CI / DI pipe of size 150mm etc complete all as specified and directed by Engineer-in-Charge Make: Capstan/woltman/kirloskar
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 20 mm dia etc complete all as specified and directed by Engineer-in-Charge
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 25 mm dia etc complete all as specified and directed by Engineer-in-Charge
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 15 mm dia etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 1,81,876.00 shall be deducted from BOQ on account of schedule of credit
L.T Associate
Mangesh Murlidhar Darwade
BHAVIN INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .