Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
10 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
GE NAGROTA
2022_MES_502804_1
GEN-75/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹87,000
Yes
18 Feb 2022
20 Jan 2022
12 Feb 2022
20 Jan 2022
10 Feb 2022
3 Feb 2022
60 days
Amount
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and directed.
Removing excavated surplus material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Supply,laying and spreading in layers dry clean river sand for cable cushioning with a layer of sand 8 Cm depth before laying & 15 cm depth after laying the cable punned down to a depth of 10 cm above the top of the cable, complete all as specified and directed.
Supply & lay burnt bricks sub class 'B' in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
S & F for laying conneting and testing of 1100 volts grade LT-XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, heavy duty electric power cable with aluminum conductor or size and type complete all as specified and directed including dismantling and taking down existing old LT cable of any size and type from pole/duct/trench/floor/well/pipe etc with cable end boxes, glands, bricks etc with necessary disconnection work and keep in safe custody for the following size of cables. (a) Cable of size 2 core 10 Sq mm Note:- (i) Excavation and earth work, sand cushioning, bricks & cable protection pipe will be measured & paid under appropriate items of Schedule 'A'
(b) Cable of size 4 core 10 Sq mm
(c) Cable of size 4 core 16 Sq mm
(d) Cable of size 4 core 25 Sq mm
(e) Cable of size 3.5 core 25 Sq mm
(f) Cable of size 3.5 core 50 Sq mm
(g) Cable of size 3.5 core 70 Sq mm
(j) Cable of size 3.5 core 95 Sq mm
(k) Cable of size 3.5 core 120 Sq mm
S7F heat shrinkable straight through cable jointing kit 1.1 KV LT 4 core XLPE cable cross sectional area 10 to 16 sqmm, complete all as specificed and directed
All as per ser item No 07.00 here in above but cross sectional area 25 to 50 sqmm
All as per ser item No 07.00 here in above but cross sectional area 70 to 150 sqmm
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm, complete all as specified and directed.
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm, complete all as specified and directed.
Material and labour for 80 mm dia light grade GI tubing with all fitting with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe complete all as specified and directed.
Material and labour for 50 mm dia light grade GI tubing with all fitting with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe complete all as specified and directed.
Material and labour for 40 mm dia light grade GI tubing with all fitting with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe complete all as specified and directed.
Material & Labour for cross arms, bracings, supports, clamps and back platre fabricated from structural steel sections including nouts, bolts, washers, welding, bending, drilling of holes for bolts in any shape or size as indicated and applying two coats of aluminium paint over a coat of red oxide primer including dismatling of existing mild steel cross arm with clamps from LT poles of any height, place and position complete all as specified and directed.
Supply ad fix and draw ACSR Weasel/Squirrelconductor of size 06 strands of aluminium of 2.59/2.11 mm dia and 1 strand of steel of 2.59/2.11 mm dia on LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG a;i,omoi, bomdomg wore amd providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down ACSR conductor of any size & type from LT oles at any height position and place complete all as specified and directed by Engr-in-Charge
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and directed.
Supply and fix LT shackle type insulators, vitreous, porcelain brown, white or green innsulators for workig pressure of 1100 volts grade of 90 mm dia, 75 mm height including galavnised mild steel strips 31 x 3 mm size and 12 mm dia bolts, nuts and washers on existing cross arms including dismantling of existing LT shackle type insulator from LT poles of any height place and position complete all as specified and directed.
Material & Labour for stay asembly comprising of stay bow ( 4000 x 14mm), stay rod 215 cm long and 20 mm dia with nuts, stay plate 300x300x6 mm thick and 2 nos of thimble complete as shown inn electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old unserviceable stay assemply complete including loop insulator wire etc from LT poles NOTE :- Earth work excavation, concrete and loop type insulator shall be measured and paid separetely under relevent items of Sch 'A'.
Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of large size with over all dimensions 90 x 140 mm clearance of hole 25.50 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position complete all as specified and directed.
S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as directed
Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays.
Material and labour for PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggreagate for making good the road cutting all as directed by Engr-in-Charge.
Material and labour for PCC (1:3:6) type B-2 using 40 mm graded crushed stone aggreagate for making good the road cutting all as directed by Engr-in-Charge.
Material and labour for lightning arrester expulsion type high tension complete with all fittings transmission class discharge capacity 65 kilo amps suitable for 11 KV including necessary connections with Over head lines & earthing fixed on 2/4 pole structure, including dismantling the old unserviceable one complete all as specified and directed.
Material and labour for switch Air break gang operated Triple pole, mechanically operating mechanisum worked from ground level for current rating upto 200 Amps 1100 Volts all with male ad female contacts, post insulator 15 Nos, operating rod, handle etc and renewal of jumpers with heavy duty alkathine pipe cable connections including dismantling of old unservicable switches vertical/horizotal mounted, including insulator & iperating mechanisum for repair/replacement of broken/worn out components and insulators etc complete all as specified and directed.
Material and labour for drop out fuse assemble expulsion type single pole for 11 KV, 100 amps capacity complete consisting of galvanised steel base plate fuse carrying breckets channels with post insulator, fuse carrier fiber glass tube with fuse eliment complete including dismatling the old unserviceable onne complete all as specified and directed.
Repair, maintenance & overhauling of existing 11 KV A. B GOD switch of any type & size including cleaning of insulator, replacing male & female contracts (where as required), greasing & oiling to operating mechanisum, setting of contacts, renewals of connections etc all for smooth fuctioning of A. B GOD switch complete all as directed by Egineer-in-Charge
Restringing of existing LT over head line of ACSR conductor after opening of binding wire from insulator & bringing the sag within limit rebinding the same withinsulator with 16 SWG aluminium wire all including renewal of jumpers with providing alkathin pipe of approved quality of jumpers, reconnecting the service connection after removing the carban material complete all as directed by Engineer-in-Charge
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
All as per item No 38 here in before but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed
M&L for earth continuiy conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site. complete all as specified and directed.
Supply and fixing for GI strip 32x6mm oin wall/batten or recessed or buried in ground all as directed by Engineer-inn-Charge
Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
S & F in repair MCB TPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified
S & F in repair MCB SPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB SPN 40 to 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
Supply and fixing in replacement indicator lamp set (RYB) complete
M & L for preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade (Spray painting outside/inside surface) of the feeder pillar box / LT Panels Outdoor / Indoor type of approximate size 900 x 600 x 500 mm complete with prior permission of Engineer in Charge. Base frame with Black enamel paint (Rate quoted shall deem to be included of Numbering of Panel/ Feeder pillar) complete all as specified.and directed by Engineer charge
M & L for Bakelite strip connector, 4 way, 100 Amp cap including electrically connections including taking down old item complete all as specified and directed.
Taking down existing junction box'S & F junction box made from FRP sheet 2.00 mm thick readymade of size 400mm x 300mm x 200mm fixed to pole/Wall with MS clamp 25 x 5 mm and suitable size of nut, bolts and washers complete all as specified and directed.
S & F in repair aluminium bus bar of required size, shape, length and making drilling for fixing in LT panel /feeder pillar/change over switch etc including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel itemsand taking down old item complete all as specified and directed.
M & L for servicing of feeder pillar box/ LT Cubical Panel , after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the rate quoted for the items. complete all as specified and directed.
Supply only aluminium lugs of any type / shape of capacity 240 Sqmm
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm
Supply only GI Nuts, bolts, screws, washers of required sizes
Supply only bus bar Insulators Epoxy type as required at site min size 45mm x 50 mm dia
S&F Extension link four set for MCCB of cap 125/160 Amp.
S&F Extension four link set for MCCB of cap 250 Amp.
S&F Extension four link set for MCCB of cap 400 / 630 Amp.
S&F current Transformer of rating from 100/5 to 400/5 CT ratio in existing panel complete all as specified and directed.
Taking down rusted portion of sheet of feeder pillar boxes, damaged hinges etc and supply and fix new hinges heavy duty type, MS sheet patch work by cutting, welding and fabricating at site as required not exceeding 0.5 Sqm , painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F locking arrangement with aldrop bolt set complete of size 225 mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified and directed.
S&F Stainless Steel Double Compression Cable Glands, Size: up to 20mm
all as per item No 75 above but of size 25 - 40 mm
all as per item No 75 above but of size 50 - 80 mm
Supply, fixing and erection truly in vertical position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 m long) complete in repairs all as specified.
Removing old burnt cut compressor from the water cooler of capacity 150 /150 & 120/160 litres including AH 13 (1 Ton),and Supply fixing, commissioning & testing of new factory reconditioned compressor complete, all as directed by Engr-in-Charge.
Removing old burnt cut compressor from the water cooler of capacity 40/80 & 60/120 litres including AH 13 (1 Ton),and Supply fixing, commissioning & testing of new factory reconditioned compressor complete, all as directed by Engr-in-Charge.
Supply and Charging suitable refrigerant Gas R-134 in water cooler of any make and capacity after flushing the complete system with (CTC) carbon tetrachloride including S & F, replacement of stainer/filter, capillary, vacuumise the complete system with vacuum pump and testing on load all as specified. Note:- The contractor shall obtained explosive carrying of certificate from the department of directorate of exlposive control and rate for the same shall be included with quoted rates.
Supply & Fix PVC float valve assembly in replacement of unserviceable PVC float valve assembly for water coolers of any capacity complete all as specified and directed.
Supply & Fix Condensing fan motor 1/10 HP, single phase AC supply, 230 volt, 50 HZ in replacement of old unserviceable Condensing fan motor. complete all as specified and directed.
Supply & Fix Condensing fan motor 1/35 HP, single phase AC supply, 230 volt, 50 HZ in replacement of old unserviceable Condensing fan motor 1/35 HP. complete all as specified and directed.
Supply & Fix starting capacitor 40/60 MFD in replacement of old unserviceable capacitor for paper type for water coolers of any make size complete.
Supply & Fix Thermostate in replacement of unserviceable Thermostate for water cooler of existing capacity and make complete all as specified and directed by Engr-in Charge .
Supply & Fix Blower fan blade in replacement of unserviceable Blower fan blade of water cooler existing size complete all as specified and directed by Engr-in Charge
Supply & Fix Over load protection in replacement of unserviceable Over load protection rellay for water cooler of size 150/150 litres complete all as specified and directed by Engr-in Charge.
Supply & Fix Over load protection in replacement of unserviceable Over load protection relay for water cooler of size 40/80 litres and 60/120 liters complete all as specified and directed by Engr-in Charge.
Supply & Fix Timer delay Relay assembly in replacement of unserviceable Relay assembly for water cooler of any cap all as specified and directed by Engr-in Charge
Supply & Fix Push cock of brass outer thread type 15mm chromium plated in replacement of unserviceable Push cock all as specified and directed by Engr-in Charge.
Supply & Fix Push cock of brass inner thread type 15mm chromium plated in replacement of unserviceable Push cock all as specified and directed by Engr-in Charge.
M & L for Cleaning of water tank of water coolers of 80 litre capacity complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Top cover complete in replacement of unserviceable Top cover Suitable to water coolers of size 40/80/120/150 ltrs water coolers.
Taking down existing unserviceable fan motor assembly complete with blades mounting frame leg with rubber bush from desert coolers and S&F Fan motor assembly complete with blades, mounting frames legs with rubber bush for desert cooler of capacity 4000/5000/6000 cum/hrs and testing complete all as specified and as directed.
Supply & Fix water pump in replacement of unserviceable water pump of desert cooler suitable for operation on AC supply single phase 230/250 volts 50 Hz.
Taking out existing old wood wool pads from desert coolers and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum/maximum capacity 3000 cum/hr and 5000 cum hrs including S&F iron with PVC insulated protective guards for holding the wood pads firrmly complete all as specified and as directed.
Supply & Fix PVC water distribution system 4 way suitable for 4000/5000/6000 Cum/Hrs of desert coolers complete with PVC Elbow, PVC Pipe (distribution system to side panel with elbow at end ) heavy duty 15mm dia in replacement of unserviceable PVC water distribution system complete all as specified and directed.
Supply & Fix side panels with wood wool for desert cooler made out of 22 gauge plane GI sheet of existing size of desert cooler in replacement of unserviceable side panels complete.
M & L for Painting of desert coolers in side out side at site of work with two coats of synthetic enemalled paint grey or any other shade (as approved) from out side complete including shutters top, bottom with spray painting machine and in side with black anti – corrosive paint (two coats) complete all as specified and directed.
Supply & Fix capacitor 3.15 to 4 MFD in replacement of unserviceable capacitor 3.15 to 4 MFD complete all as directed.
Supply & Fix New factory reconditioned compressor of sealed unit for refrigerator of capacity 165 liters in replacement of unserviceable/old burnt compressor as per requirement all as specified and directed complete.
Supply & Fix New factory reconditioned compressor of sealed unit for refrigerator of capacity 300/3105 liters in replacement of unserviceable/old burnt compressor as per requirement all as specified and directed complete. Make : Godrej /Whirlpool/Tecumsew
Supply and Charging suitable Gas, R-134 in Refrigerator after flushing the complete system with (CTC) carbon tetrachloride and replacement of capillary, of suitable sizes, filter, vacumise the complete system with vacuum pump and testing on load all as specified of capacity 165 liters.
Supply and Charging suitable Gas, R-134 in Refrigerator after flushing the complete system with (CTC) carbon tetrachloride and replacement of capillary, of suitable sizes, filter, vacumise the complete system with vacuum pump and testing on load all as specified of capacity 300/310 liters.
Supply & Fix Over load protection relay in replacement of unserviceable Over load protection relay, complete for any size refrigerator complete
Supply & Fix Thermostat in replacement of unserviceableThermostat suitable for any size of refrigerator
Supply & Fix Timer delay relay in replacement of unserviceableTimer delay relay, suitable for refrigerator of any size. complete all as specified and directed.
Supply & Fix Bulb in replacement of unserviceable Bulb suitable for refrigerator of any size.
Supply & Fix Condenser coil of copper in replacement of unserviceable Condenser coil of copper complete of refrigerator of any size.
Supply & Fix Waste water tray in replacement of unserviceable Waste water tray suitable for refrigerator of any size.
Supply & Fix Magnetic rubber gasket for door of refrigerator in replacement of unserviceable Magnetic rubber gasket of any size. complete all as specified and directed.
Supply & Fix front door complete in replacement of unserviceable front door Suitable to deep freezer of size 300/310 ltrs water coolers. complete all as specified and directed.
Supply & Fix Door lock with key suitable for 165/300/ 310 liters cap refrigerator in replacement of unserviceable Door lock complete. complete all as specified and directed.
Supply & Fix freezer cabinet suitable for 165 liters cap refrigerator in replacement of unserviceable freezer cabinet complete. complete all as specified and directed.
Supply & Fix freezer cabinet suitable for 300/ 310 liters cap refrigerator in replacement of unserviceable freezer cabinet complete. complete all as specified and directed.
S&F Cable PVC insulated and sheathed flexible 3 core of size 23/ .0076 with multistrand copper conductor complete all as specified and directed.
Supply & Fix New compressor in Replacement of old UNSV compressor sealed unit for Deep Freezer of cap 300/320 Ltr as per requirement all as specified and directed complete.
Supply and Charging suitable Gas, R-134 in Deep Freezer after flushing the complete system with (CTC) carbon tetrachloride and replacement of capillary, of suitable sizes, filter, vacumise the complete system with vacuum pump and testing on load all as specified for capacity 300/320 ltr Deep Freezer. Note:- The contractor shall obtained explosive carrying of certificate from the department of directorate of exlposive control and rate for the same shall be included with quoted rates. complete all as specified and directed.
Supply & Fix Over load protection for Deep Freezer in replacement of old unsv over load protection of any capacity complete.
Supply & Fix Thermostat for Deep Freezer in replacement of old unsv Thermostat complete.
Supply & Fix Timer delay relay for Deep Freezer in replacement of old unsv Timer delay relay complete
Supply & Fix Condenser coil complete for Deep Freezer in replacement of old unsv Condenser coil complete of any capacity. complete all as specified and directed.
Supply & Fix Condensing fan motor for Deep Freezer in replacement of old unsv Condensing fan motor suitable for deep freezer. complete all as specified and directed.
Supply & Fix Top cover complete in replacement of unserviceable Top cover Suitable to deep freezer of size 300/320 ltrs water coolers. complete all as specified and directed.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 0.5 KVA complete all as specified.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 1 KVA complete all as specified. complete all as specified and directed.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enameled copper wire of suitable gauge to match with the existing one including all related work and testing complete of size capacity 2/3 KVA complete all as specified and directed.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 4 KVA complete all as specified and directed.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 5 KVA complete all as specified and directed.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 6 KVA complete all as specified and directed.
M & L for Replacement limit switch suitable for SP voltage stabilizer capacity 1/3/5 KVA complete all as specified and directed.
Material and Labour for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following capacity of water cooler / refrigerator :- (a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep Freezers any capacity
Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (a) Water coolers of capacity up to 150 liters.
(b) Refrigerators of capacity 210 to 310 ltrs.
(c) Deep freezers 200 to 300 ltrs capacity.
Supply and replace starting relay suitable for (a) Water coolers 40 to 150 ltrs cooling capacity :-
(b) Refrigerator of 165 to 310 liters capacity.
(c) Deep freezers of 200 to 425 ltrs capacity.
Supply and replace thermostats of :- (a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep freezers of 200 to 325 ltrs capacity.
Supply and charging refrigerant gas R-22/R-134 (A) up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed by Engr-in-Charge (a) Water cooler 40 ltr cooling cap.
(b) Water cooler 80 ltr cooling cap.
(c) Water cooler 150 ltrs cooling cap
(d) Deep freezers of any capacity.
(e) Refrigerators of any capacity.
Supply and replace condenser unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge. (a) Water coolers 40/60 ltrs capacity.
(b) Refrigerator of 165 to 195 ltrs capacity.
(c) Deep freezers of 200 to 300 ltrs capacity.
Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.
Supply and replace overload protector of : (a) Water coolers/ Refrigarator upto 150 ltrs cooling capacity.
(b) Deep freezers of upto 425 ltrs capacity.
Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :- (a) Water coolers of any make and cap 40 to 150 ltrs capacity.
(b) Deep freezers of any make & cap 200 to 300 ltrs capacity.
Supply and charging refrigerant gas R-22/R-134 (A) up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed by Engr-in-Charge. Make Paragon,Mefron (Note : Above second floor contractor will arrange crain / scaffolding with safety device) (a) Window type room air conditioners of capacity 1.5 Ton.
(b) Split type AC 1.5/2.0 Ton capacity
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for : (a) Window type room air conditioners of capacity 1.5 Ton cap.
(b) Split type AC 1.5/2 Ton capacity.
Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (a) Window type air conditioners of capacity 1.5 /1 Ton
(b) Split type AC 1.5/2.0 Ton capacity.
Supply and replace capacitors of the following capacities for ACs (a) 3.15 ,4 & 6 Mfd
(f) 45+6 Mfd Seven Pin
Supply and replace starting relay suitable for :- (a) Window type room air conditioners of capacity 1/1.5 Ton cap.
(b) Split type AC 1.5/2 Ton capacity
Supply and replace thermostats of :- (a) Window type room air conditioners of capacity 1/1.5 Ton cap. Make Danfoss,Annapooma
(b) Split type AC 1.5/2 Ton capacity.
Supply and replace oeverload protector of :- (a) Window type room air conditioners of capacity 1/1.5 Ton cap.Make Usha,Annapooma
(b) Split type AC 1.5/2 Ton capacity.
Supply and replace condenser unit make of copper of the following appliances including making of all connections as specified and directed by Engr-in-Charge (a) Window type room air conditioners of capacity 1/1.5 Ton capacity.
(b) Split type AC 1.5/2 Ton capacity.
Supply and replace metal clad/sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB complete including making all connections. complete all as directed by Engr-in-Charge.
Supply and replace contact unit of split type air conditioning of 1.5/2 Ton cap complete all as directed by Engr-in-Charge.
M & L voltage stabilizers AC single phase. 2 to 5 KVA of any make by opening of the body, cleaning of internally, checking and tigtening of all terminal connections including replacement of worn out terminal connectors, screws, bolts complete all as directed by Engr-in-Charge.
Supply And Fix with repair of defective burnt motor from unit and testing all as directed for the following;- (a) Window type AC of any make capacity 1/1.5 Ton cap
(c) Split type AC of any make and capacity 1.5/2 ton.
Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 3/8"diameter
Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 5/8"diameter
Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter
Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter
Supply and fix PCB cercuit board complte suitable for 1.5/2.0 ton capacity split type air conditioneer complete all as directed by Engr-in-Charge.
Supply and fix PCB cercuit board complte suitable for 1.5/2.0 ton capacity Window type AC complete all as directed by Engr-in-Charge.
Supply and fix in repair Remote of any size and capacity of split AC . complete all as directed by Engr-in-Charge.
Supply in replacement of indoor colling unit 1.5 Ton capacity copper tubing with rotary fan suitable of existing make with suitable remote complete all as directed by Engr-in-Charge.
S&F in replacement of desert cooler 1350 Rpm capacity motor with fan blade of existing make with all arrangement complete all as directed.
Replacement of water circulation submersible pump of desert cooler suitable for operation on AC supply single phase 230/250 volts 50 Hz. complete all as directed by Engr-in-Charge.
Taking out existing old wood wool pads from desert coolers and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum/maximum capacity 3000 cum/hr and 5000 cum hrs including S&F PVC insulated protective guards for holding the wood pads complete all as specified and as directed.
Replacement of PVC water distribution system 4 way suitable for 3000/4000 Cum/Hrs of desert coolers complete with PVC Elbow, PVC Pipe (distribution system to side panel with elbow at end ) heavy duty 15mm dia all as directed.
Replacement of unserviceable side panels with wood wool 2" thick for desert cooler made out of 22 gauge plane GI sheet of existing size of desert cooler complete. (Each Set Of Three Panels) complete all as directed by Engr-in-Charge.
Painting of desert coolers in side out side at site of work with two coats of synthetic enamel paint grey or any other shade (as approved) from out side complete including shutters top, bottom with spray painting machine and in side with black anti – corrosive paint (two coats) complete all as specified and directed.
ASHOKA ENGINEERS AND BUILDERS
J S ENGINEERS
ASHFAQ AHMED MANHAS
M/S Shankardass Devidass
ASHWANI KUMAR KHAJURIA AND SONS
Mahajan Auto Traders
Nitika electricals and engineers works
Allied Technologies
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .