Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
22 Mar 2021, 9:00 amClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
RENOVATION OF ROOM NO 04 06 OF BLDG NO P178 OLD MMG AT DIAT ADDN ALTN WITH REPAIR WORKS TO BLDG NO P142 COMMUNITY CENTRE GYM LIBRARY OF JCOs AND ORs AND SPECIAL REPAIRS TO ROAD AROUND BLDG NO P322 P323 AND P324 INCLUDING A MINOR WORKAT MILITGIRINAGAR
2021_MES_425332_1
GE I R AND D GNR TOKEN 60 OF 2020 21
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE I R AND D GIRINAGAR PUNE 411025
₹88,000
Yes
23 Mar 2021
24 Feb 2021
23 Mar 2021
24 Feb 2021
22 Mar 2021
10 Mar 2021
24 Feb 2021 - 8 Mar 2021
Amount
PART-I B/R PORTION (RENOVATION TO ROOM NO. 4 & 6 DIAT) Dismantling wrought iron or mild steel work of any description.
Taking down chowkats or frames of wooden exc 1.5 sqm & n.exc. 4 Sqm with Shutters (without taking off shutters from the frames).
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removal of debris outside MD land all as specified and directed.
Demolition of cement concrete (Reinforced) in roofs, floors, beams staircase, landing chajjas and similar suspended work and removing from site all as specified and directed.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
Demolition of Brickwork or stone/boulder masonary, built in Cement mortar
M&L for Pre-cast cement concrete block masonry with solid blocks type C1 1:3:6, exc. 10 cm in width and setting in mortar 1:6 complete
Rendering 10 mm thick of fair faces of brick work or concrete surface in CM 1;6. finished even and smooth without using extra cement.
Rendering 20 mm thick of fair faces of stone masonary work in CM 1;6. finished even and smooth without using extra cement.
Rendering 20 mm thick of sand faced plaster as specified on stone work in CM 1:4 with waterproofing compound in double coat (15+5mm).
Rendering 15 mm thick of fair faces of brickwork or concrete work in CM 1:4. in double coat finished even and smooth without using extra cement with waterproofing compound.
Supply only waterproofing compound
Forming jambs etc to opening including cutting toothing and properly bonding into old work including facing and pointing (if necessary) to match existing work complete in CM 1:4
M&L for preparation of surfaces and applying 2mm thick wall care putty on walls/concrete surface internally complete all as specified and directed.
M&L for two coats of external acrylic (100%) waterproof emulsion paint Apex Ultima or equivalent complete all as specified and directed over a coat of alkali resistant primer on new plastered surfaces of wall including necessary scaffolding required for painting work, safety measures etc
Complete removal of existing treatment for surfaces of walls/roof projection/chajja including concrete (plastered or un plastered) by brooming down and scraping wherever necessary and apply two coats of external acrylic (100%) waterproof emulsion paint Apex Ultima or equivalent including necessary scaffolding required for painting work, safety measures etc complete all as specified and directed
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for doors , windows, ventilators, partition wall etc. with one or more rebates, shutters, grills including joining cleat glazing clips for fixing etc. complete all as specified. (Jindal Section No 20048=0.942 Kg/M for door frame, Glazing Clip 19370=0.109 kG/M, Partiiton section 14066= 1.345 Kg/Rm)
S&F anodized aluminium door shutters aluminium section weighing 0.55kg/m including necessary joining cleat glazing clip, rubber neoprene packing, handles 2 no in each door, hinges, anodised aluminium snap beading screws etc complete all as specified. including Powder coating of any colour (Thickness of powder coating not less than 50 Micorn)
M&L for Powder coated aluminium window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section wighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, Handle, lock, powder coated aluminium snap beading scres etc complete
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18mm & fixed with stainless steel wire staples all as specified.
M&L Framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290.Gde-E-165 for MS framed work as in trusses, purlins, rafters, post etc conforming to grade E-250 (Fe 410W, quality 'A') including shaped washers, including necessary cutting required length, notching, drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plate, gusset plate and also erecting in true position complete as directed.
Preparation of new decorated Steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer.
S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame work .
M&L for Sheet glass, ordinary quality, in squares exc 0.5 sq. m each pane 4mm Thk in doors, in partition
M&L for solar control film 25micorn relfective type sticked to glass panes as per insturction of manufactureres
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints supplied and fixed
S&F for holdfast confirming to Fe 290 Gde E-165
M&L for PCC 1:2:4 type B1 (20mm Graded stone aggregate) as in filling in frame and bed block for fixing of holdfast fo door frame.
S & F Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides 40mm Thk
S&F Decorative Laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive to Plywood as per manufacturers instruction.0.9mm Thick
Preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink Primer
Preparing surfaces of wood and wood based materials, steel and iron work, new or old of any description and girth not otherwise described and treated with tar or coal tar black paint
M&L Aluminium (Extruded section) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
M&L for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty and fixed
M&L for 125mm high butt hinges heavy weight cold rolled mild steel and fixed
S&F brass sliding door bolts with sand or die cast brass hasp and staple (Bolt Type) and fixing bolt with rolled or drawin brass bolt and fixed length of bolt 250mm
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F Brass handles, polished type, of size 150 mm
M&L for formwork to sides and soffits of lintel beam, floor or roof beam etc
M&L for formwork to soffits of suspended slab such as roof slab, floor slab, chajja and similar work not exceeding 200mm Thick
M&L for RCC Nominal Mix Type B1 1:2:4 (20mm Graded aggregate) concrete in lintel beam, cantilever etc
M&L for RCC Nominal Mix1:2:4 Type B1 (20mm Graded Aggregate) concrete in Chajja and Similar works
S&F TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns hooking ends and bindng with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Same as per item above but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders
M&L for hangers 3mm dia GI adjusting level fixed to roof slab/steel truss by means of ceiling cleats made out of GI flat 40X3mm size 60mm long.
M & L for cement concrete type D-2 1:4:8 (40mm graded aggregate) 75mm thick
M&L for coloured vitrified tiles 600x600x10mm thick as in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles, laid over and including 20mm thick backing coat in CM 1:4 all as specified and directed by Engr-in-Charge.
M&L for coloured vitrified tiles 600x600x10mm thick as in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles, laid over and including 10mm thick screed bed in CM (1:6). all as specified and directed by Engr-in-Charge.
M & L for granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Rounding edges of stone one edge, such as in steps, cooking platform, window cill and other similar situation.
M&L for 4mm thick Prelam glossy finish PVC sheet in strips & channel feathered at the edges for fixing on solid PVC wall, Insulated PVC wall lining and Soild PVC Partition inclusive of solvent and fixed at site in Aluinium framework.
S&F Venation blends rolling or sliding type with design on inner face vertical type made out of fiber cloth fixed, to wall with necessary Aluminium brackets, screws etc including Alluminium frame for venation blinds rolling type etc all as approved by GE all as specified and directed.
M&L for Magnetic white board of 6mm Thick Sliding type fixed in powder coated aluminium two track section with movable board of size 1.2m X1.2m height. Overall size shall be 2.4m X 1.2m High Fixed to wall complete all as specified.
PART-I B/R PROTION (SPL ITEMS RENOVATION TO ROOM NO. 4 & 6 DIAT) S&F of 600X600X0.7mm thick powder coated aluminium tile square tegular with semi concealed grid. The tile shall be laid on semi concealed grid system with 15 mm white flange incorporating 6 mm central reveal in white/black colour and with web height of 38 mm and load carring capacity of minimum 11.68 kg/sqm.Silhouette. main runner and cross tees to have mitred ends & birdmouth notches to provide mitred cruciform junction. The T sections have galvanising of 120 gms/sqm ( Make :Armstrong, Saint Gobain)
M&L for complete removal of existing paint and applying two coats of acrylic emulsion paint (luster paint) internally over a coat of primer over 2mm thick coat of putty two layers on old or new surfaces of wall
PART-II B/R PORTION (ADDN/ALTN TO P-142 COMMUNITY HALL MILIT) Demolition of cement concrete in floors and pavings n. exc. 15cm thickness (below or above ground level).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
Taking down chowkats or frames of wooden or steel exc 1.5 sqm & n.exc. 4 Sqm with Shutters (without taking off shutters from the frames).
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
Rendering 15 mm thick of fair faces of stone wall surface in CM 1;6. finished even and smooth without using extra cement.
M&L for rendering 5mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement.
M&L for rendering 10mm thick on fair faces of brick work, stone wall or concrete surfaces in finished even and fair in CM 1:6 including rough cast plaster complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in floor levelling course and in similar situations 25mm thick.
M&L digitally glazed coloured /light shade vetrified tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over 15mm thick screed bed in CM 1:6 .
M&L digitally glazed coloured /light shade vetrified tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in skirting etc and joineted neat in cement slurry and pointed in white or colour cement to match over 10mm thick screed bed in CM 1:4 .
M&L for Non Skid Ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L Glazed ceramic coloured tiles in vertical surfaces 300 x 450 x 7mm as in dado/skirting etc and joineted neat in cement slurry and pointed in white or colour cement to match over 10mm thick screed bed in CM 1:4 .
Raking out joints/pointing to random rubble or polygonal rubble uncoursed or brought upto couses stone work built in cement or cement lime mortar including necessary scaffolding complete all as directed by Engr-in-Charge.
Flush pointing in CM 1:4 to random rubble or polygonal rubble uncoused stone masonary wall including preparation of surface including necessary scaffolding arrangement complete all as directed by Engr-in-Charge.
M & L for granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Rounding edges of stone one edge, such as in steps, window cill, cooking platform and other similar situation.
S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F anodised powder coated (thickness of powder coating not less than 50micron) aluminim window and ventilator shutters, fixed type without sash bar, aluminium section weight not less than 0.55kg/mtr including necessary joining cleats, glazing clips, rubber packing, screws etc. complete all as specified.
M&L for 3mm thick figured glass, pin head type and glazing with not exc 0.5Sqm in each pane to aluminium frame work for ventilators complete.
M&L for mild steel framed work such as grills, gratings etc. with ends of bars shouldered or riveted or gorged into spikes framed guard bars barred to windows, iron door,ladders framed balusters, walk ways, railing, frame work for water tank and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M&L for two coats of oil bound distemper over a coat of primer on New surfaces of wall complete.
M&L for two coats of oil bound distpemper over a coat of primer on old surfaces of wall complete
M&L for applying three coats of white wash on ceiling including preparation of new plaster surfaces complete.
M&L for two coats of external acrylic (100%) waterproof emulsion paint Apex Ultima or equivalent complete all as specified and directed over a coat of alkali resistant primer on new plastered surfaces of wall including necessary scaffolding required for painting work, safety measures etc.
Complete removal of existing treatment for surfaces of walls/roof projection/chajja including concrete (plastered or un plastered) by brooming down and scraping wherever necessary and apply two coats of external acrylic (100%) waterproof emulsion paint Apex Ultima or equivalent including necessary scaffolding required for painting work, safety measures etc complete all as specified and directed
M&L for preparation of surfaces and applying 2mm thick wall care putty in two layers on walls/concrete over new or old plaster surfaces internally complete all as specified and directed.
M&L for pressed steel frmaes for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified, supplied and fixed size 105X60mm complete.
M&L for PCC 1:3:6 type C-0 (using 12.5mm graded aggregate) as in filling steel frames etc. incl necessary form work complete.
M&L for 40mm thick Flush shutters with lipping all around of solid core construction with block board core and ply wood face panels commercial type on both side complete.
M&L for brass, sliding door bolt with sand or die cast brass hasp, staple (bolt type) length 300mm fixing bolt with rolled or drawn brass bolts and fixed.
M&L for floor door stopper of brass body and tongue with hard drawn steel spring overall length of cover plate 140mm complete.
S&F 150mm long extruded brass handles, fabricated type polished complete.
S&F 200mm long brass barrel tower bolts, with cast or sheet barrel and rolled and cast bolts fixed.
S&F Door closer Aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80kg and fixed.
M&L for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces exceeding 10cm girth or width.
S&F factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of M.S tubes for top & bottom rails; M.S frame shall be covered with heat moulded plain colour PVC ‘C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing as per product Drg given on Sl. Page No. 156 of SSR Part-II 2010 Refer item No. 8080 as specified and directed by Engr-in-charge.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 250 mm.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F aluminium handles, anodised, cast type, of size 150 mm
S&F in repair vitreous china orrisa pan squatting pattern 580x440mm with integral foot rests including P or S trap, including PVC low level flushing cistern 10 ltr capacity complete all as directed by Engr-in-Charge.
S&F 15mm dia 45cm long PVC water connection with PTMT nuts and washers all as directed by Engr-in-Charge.
S&F Wash hand basin, vitrous china, coloured flat back of size 550 x 400mm encluding cutting for and pining in ends of brackets or erecting stand including 32mm dia PTMTwaste coupling, waste pipe, 15mm dia bore pillar taps, cast copper alloy chromium plated fancy type fixed complete.
S&F in repair rotational moulded polyethylene water storage tanks 500ltrs (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and dismantling of existing cement water tanks.
S&F 15mm dia GI pipe medium grade with all fittings laid in floor or fixed to walls including tacking down old GI tubes.
S&F 20mm dia GI pipe medium grade with all fittings laid in floor or fixed to walls including tacking down old GI tubes.
S&F in repair angle/stop valves cast copper alloy, screwed down high pressure fancy type chromium plated 15mm dia with long shank and cup (cocealed type) all as specified and directed by Engr-in-charge.
S&F in repair CP Bib taps 15mm dia with crutch or butterfly handle fancy type.
Demolition and breaking up drain AC/PVC pipes set in cement mortar 100mm up and below ground level.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors bore of the pipe 110mm.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore of the pipe 75mm.
S&F PVC (SWR) bends any radius 110mm dia with access door.
S&F PVC (SWR) bends any radius 75mm dia with access door.
S&F PVC (SWR) Single 'T' Junction equal or unequal with oval access door bore of the pipe 110mm.
S&F PVC (SWR) Vent Cowl of 110 mm dia .
M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement outlet dia 75mm in repair.
S & F in repairs gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 20mm bore.
S&F in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20mm bore.
S&F Chromium plated 20mm dia 'D' type between flanges towel rail 60cm long complete.
S&F Glass self assembly size 30cm x 15cm complete.
Demolition of concrete of any description and in any position not otherwise specifically provided for
M&L for cement concrete type B1 1:2:4 (20mm Graded aggregate) 40mm thick.
M&L for 10 mm thick rendering in CM 1:4 over concrete surfaces mixed with water proofing compound @ 3% by weight of cement complete all as specified. Note: Water Proofing compound shall be measured and paid for seprately as "Supply Only"
M & L for APP based polymeric membrane minimum weight 3 Kgs/Sqm and minimum 3 mm thick reinforced with polyster non-woven fabric ( wt not less than 150 gms/sqm laid over primed surface with bituminous primer conforming to IS- 3384 @ 0.3 litre/sqm and finishing with preventive coat with aluminium paint @ 100m/sqm all as directed and specified including vertical surfaces.
Supply only WPC.
M&L for Two coats of synthetic enamel paint over a coat of red oxide on steel surfaces exc 10 cm width or girth etc.
M&L for chequered cement concrete tiles coloured 30cm x 30cm x 25mm thick with grey cement and no pigment, set and jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 complete.
M&L for cement concrete type C2 1:3:6 (40mm Graded aggregate) as in surface channels and drains including necessary form work for sauccer drain complete.
Extra for forming fair finished drain or channel 45cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred /stopped ends etc.
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection.
PART-III B/R PORTION (SPL REPAIRS TO ROAD) Repair to pot holes any depth not exc 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc cutting around edges to at least 25 mm in depth making good by applying tack coat @ 5Kg/10 Sqm putting in premixed bituminous macadam, well rammed and sealed with binder with 6.80 kg per 10 sqm, blinded with 0.06 cum of stone chippings, 6.3 mm size and again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm complete all as specified and directed.
Preparing of existing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning with gunny bags to remove all loose dirt etc and M & L in applying evenly a tack coat of paving bitumen VG-10 confirming to IS:W-73:2006 @ 5 Kg/10 Sqm of road surface with Mechanical Sprayer, operated by hot pressure mechanism complete all as specified & directed.
Preparing of unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning with gunny bags to remove all loose dirt etc and M & L in applying evenly a tack coat of paving bitumen VG-10 confirming to IS:W-73:2006 @ 10 Kg/10 Sqm of road surface with Mechanical Sprayer, operated by hot pressure mechanism complete all as specified & directed.
Scarifying or picking gravelled macadam or bituminous macadam surfaces in area n.exc 400 sqm and depth not exceeding 50 mm deep complete all as specified and as directed.
M&L for providing and laying 75mm or less thickness (Consolidated thickness) premix bituminous macadam(design mix) with crushed and graded coarse stone aggregate filler (cment) and sand (fine aggregate) mixed with 4% binder content using paving bitumen byu VG-30 grade weigth of total mix, mixing bituminuous macadam in hot mechanical plant and laiid with mechanical paver complete rolled with 8 to 10 tonne power roller to required camber and gradient comhplete, all as specified and directed. Note : . (i) Premix bituminous mecadam shall be designed as specified and contractor shall quote his rates considering the bitumen contents as specified.
M&L providing and laying bituminous premix asphaltic semi dense concrete 30 mm consolidated thickness with 5.5% binder VG-30 confirming to IS: W-73:2006 paving bitumen content by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and directed. Note : Mixing bituminous concrete in Hot mix plant, laying, spreading uniformly by means of Mechanical Paver, rolled with 8 to 12 tonne power roller to required gradient and camber. (ii) Semi dense asphaltic bituminous concrete shall be designed as specified and contractor shall quote his rates considering the bitumen contents as specified.
M&L for marking 2.50 mm thick centre line, stop line, dashes, arrows, brackets & similar work on road surfaces as per IRC pattern with thermo plastic paint of approved quality & make with 8% glass beads laid at temperature 1600 C with a special applicator machine complete all as per manufacturer’s instructions & traffic diversion arrangement. (Make-CMS Bombay/Shivalik Prime-Chandigarh/Ritactor-Meerut/SN Industries-Delhi/Reliance Thermoplast, Delhi/CMS Traffice System Ltd, Mumbai)
PART-I E/M PORTION (ADDN/ALTN TO ROOM NO . 4 & 6 DIAT) Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials for taking credit and making good disturbed surfaces of walls, floors and roofs etc all as specified and as directed.
Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed.
Taking down carefully unserviceable DBs any type/size With MCCBs/Isolator etc and disconnecting and making good disturbed surfaces complete all as directed.
M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through heavy duty PVC casing capping fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly including concealed modular flush boxes including Modular box , modular cover plates with frame mounting for housing the switches, socket outlets etc, all as specified and directed M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through heavy duty PVC casing capping fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly including concealed modular flush boxes including Modular box , modular cover plates with frame mounting for housing the switches, socket outlets etc, all as specified and directed . (a) One light point controlled by one way switch.
(b) One Fan point controlled by one way switch.
(c) One 3 pin switch socket outlet point 6 Amps on independent board.
(d) One 3 pin switch socket outlet point 6 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 16 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch, single pole,one way 6 Amps capacity
S & Fix modular switch, single pole, one way 16 Amps capacity
S & Fix modular socket, outlet 2 in 1, 6 Amp capacity
S & Fix modular, socket 6A/16A 2 in1, 16 Amp capacity
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix modular fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts, 4 step complete all as directed.
S & Fix LED efficient LED recessed mounting fitting 2' X 2' luminaire to enhance the delight of occupents with comfortable experience through its classic design & glare free soft illumination all as specified & directed Make - Bajaj Cat Part No - BZRSQL 36L LED GXD WH SD or eqvt in Wipro/Havell/Crompton.
S & Fix sheet metal enclosure distribution board SPN 2 way 240 volts 100 amp busbar rating with IP 43 protection and Single door, suitable for mounting MCBs and all as specified and as directed.
S & Fix sheet metal enclosure distribution board SPN 12 way 240 volts 200 amp busbar rating with IP 43 protection and double door, suitable for mounting MCBs and all as specified and as directed.
S & Fix sheet metal enclosure distribution board SPN 8 way 240 volts, 200 amp busbar rating with IP 43 protection and double door, suitable for mounting MCBs and all as specified and as directed.
S & Fix MCB single pole, 240 volts, 6 to 40 Amps, all as specified and as directed.
S & Fix MCB single pole & neutral, 240 volts, 32 to 40 Amps, all as specified and as directed.
M & L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC Casing caping fixed to walls / roofs / floors / ceiling etc with its accessories all as specified and directed by Engr-in -charge for the following. (a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire
(b) 2x4 sq mm and 1x4 sq mm as earth wire
(c) 2x6 sq mm and 1x6 sq mm as earth wire
Taking down and refixing of Ceiling fan any size/sweep, including oiling, Greasing and cleaning and applying two coats of synthetic enameled paint after preparation of surface complete over a coat of primer.
S & Fix for ceiling fan down rods 1.0 M Long of 15 mm dia GI pipe to the existing trusses of any height including necessary welding & fixing with clamps and nut bolts etc complete all as specified and as directed.
S & Fix LAN socket connecter RJ45 with socket with copper feed modular type all as directed by Eng in Chrage.
S & Fix LAN cable 4 pairs PVC insulated and PVC sheathed all as directed by Engr in Charge
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality, Refrigerent R-32 with inverter technology of capacity 1.5 TR, Make :- Voltas / Carrier.
S & Fix Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCBs with 240 V 20 AMPs MCBs.
S & Fix suction and discharge copper tubing pipe 3/8" and 5/8" for split type AC including provision of insulation on tubing, PVC insulated flexible multistranded copper cable 3 core 2.5 sqmm all as directed by Engr-in-charge.
S & Fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilized at 230 volts with accuracy +/- 2.5% and of capacity 4 KVA, Make :- V Guard / M Guard
Cutting holes by core cutting machine or other mean into or through cement concrete slabs, chajjas, reinforced or otherwise, brick / stone masnary walls etc. cutting area n. exe. 100 sqcm and making good disturbed surfaces
S & Fix LED street light 30 W CUB type building security light pressure die cast aluminium housing LED street light lumaniries with IP 65 and including bracket, nut,bolt,clamp etc complete all accessories and fixing arrengenment all as specified and directed by Engr-in-charge Cat part no - ENSTP 30 L WH PCSD or eqvt in Wipro/Havell/Crompton.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less that 1.5 M below normal grouond level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe withand funnel, PCC 1:3:6 Type C-1 chamber with 40mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
PART-II E/M PORTION (ADDN/ALTN TO BLDG NO. 142 COMMUNITY HALL) Taking down carefully aluminium / copper point wiring complete (light, fan socket & power) including unserviceable fixtures and fittings such as switches ceilimg roses pendents regulators sockets light fittings etc complete removing material for taking credit & making good disturbed wall / floor etc complete all as directed by Engineer-in-Charge
Taking down sub main wiring with UG Cable complete including fitting and fixtures, removing materials and making good the disturbed surfaces of walls, floors, roof etc, all as specified and as dirfected.
Taking down carefully unserviceable VTPN/DBs with MCB any type/size disconnecting and making good disturbed surfaces complete all as directed
M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through and including rigid PVC cassing and caping fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor cable as earth dolly, including Concealed MS box with 3 mm thick laminated sheet cover fixed with brass screws and cup washers for mounting of plate mounting for housing the switches, socket outlets, fan regulators etc and including of cutting chasses making good disturebed surfaces all as specified and as directed . (a) One light point controlled by one way switch
(b) One fan point controlled by one switch and one regulator.
(c) One socket point 6 Amps on same board
(d) One socket point 6 Amps on independent board
All as per item above here in before but with copper conductor cable for one 5 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix piano flush type switch 1 way 5A
S & Fix piano flush1 way 15A
S & Fix socket out let 5A 2 in 1,5pin
S & Fix socket out let 5A/15A-2 in 1, 5 pin
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix fan regulator electronic type volts AC 50 HZ ,4 step, 100 v complete all as directed.
S & Fix lamp holder PVC type with back plate suitable for lamp holder fitting.
S & Fix LED Batten for LED tube light channel 18 watts fitting with necessary braket, clamps, incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make - Bajaj Cat Part No - BLRB-DB 118 or eqvt in Havells / Crompton / Wipro etc
S & Fix LED tube light Rode 18 watts with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make - Bajaj Cat Part No - BLRB 18W LED or eqvt in Havells / Crompton / Wipro etc
S & Fix LED 10 W Batten integrated LED chanel fitting integral sleek extruded polycarbonate LED chanel with acrylic cover,Neutral/cool white with all accessories all as specified and directed by Engr-in-charge Make-Bajaj Cat Part No - BCLSB 10 WH, Wipro/Havells/crompton or other.
S & Fix MCB DB TPN 4 ways,with metal double door ,IP -43 protection suitable for MCB as incommer and MCB as out going, TPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to legrand for fixing on surface of wall all as directed by Engr-in charge. Make:- Legrand or eqvt in Standerd/ C & S/L&T/ABB.
S & Fix sheet metal enclosure distribution board SPN,12 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete Make:- Legrand or eqvt in Standerd/ C & S/L&T/ABB
S & Fix sheet metal enclosure distribution board SPN,8 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete Make:- Legrand or eqvt in Standerd/ C & S/L&T/ABB
S & Fix sheet metal enclosure distribution board SPN, 2 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete Make:- Legrand or eqvt in Standerd/ C & S/L&T/ABB.
S & Fix MCB 4 pole, 415 volts,10 KA, 63 Amps, all as specified and as directed.
S & Fix of MCB single pole and neutral, 240 volts, 5 to 40 Ampere, rupturing capacity 10 KA complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 5 to 40 Ampere, rupturing capacity 10 KA complete all as specified and directed.
S & Fix LED street light 30 W CUB type building security light pressure die cast aluminium housing LED street light lumaniries with IP 66 and complete accessories all as specified and directed by Engr-in-charge. Make: Bajaj Cat No-ENXT P 30L WH CR PC SD or Eqvt in Havells/Bajaj/Jaquar.
Taking down & refixing of defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and examine & carry out the servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of painting re-fixing and testing in all respect for smooth running complete.
S & Fix PVC body Exhaust fan AC single phase 230 volt 900 RPM of size 200 mm sweep with louver and fixing arrangement complete all as specified & directed. Make : Bajaj - Maxima DX / Usha/Crompton/ havells
M&L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC casing and capping with its accessories all as specified and directed by Engr-in -charge for the following (a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire
(b) 2x6 sq mm and 1x6 sq mm as earth wire
M & L for Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less that 1.5M below normal ground level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
PART-II E/M PORTION (ADDN/ALTN TO P-142 COMMUNITY HALL MILIT ELECTRIFICATION) Supply and Laying and testing cable XLPE insulated heavy duty electric cables with multistanded aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm, 4 core cable connecting lugs, glands,jointing materials etc, laid on surface,wall, floors, roof, ducts and fixing using clamps, saddle complete all as directed by Eng-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
Supply & Laying 40 mm outside dia double wall corrugated pipe (DWC) ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement.
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 30 cm wide and not exceeding 60 cm deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
M &L for GI pipe ''light grade'' for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA (a) 40 mm dia
PART-IV E/M PORTION (MINOR WORK) M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through and including rigid PVC cassing and caping fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor cable as earth dolly, including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including Concealed modular cover plates with frame and modular flush boxes for mounting for housing the switches, socket outlets etc, all as specified and directed including of cutting chasses making good disturebed surfaces all as specified and as directed . (a) One fan point controlled by one switch.
(b) One socket point 6 Amps on same board
(c) One socket point 6 Amps on independent board
All as per item above here in before but with copper conductor cable for one 5 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch1 way 6A, 1 module
S & Fix modular switch1 way 16A, 1 module
S & Fix Modular socket 6A 2/3 on combined 2 module
S & Fix Modular socket 6A/16A-2/3 pin combined 2 module
S & Fix Ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix Wall mounted fan 300 mm sweep white colour, 230 volts, 45 Watts including fixing arrengenment on wall all as directed. Make- Havells / Bajaj / Crompton.
J.G.Goel
Aakar Constructions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .