Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹32.2 L+₹1.1 L (3.64%)Rejected-Finance HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Quoted rate higher than L1 Bidder | |
| 3 | L3₹32.7 L+₹1.6 L (5.14%)Rejected-Finance | L3 | Rejected-Finance Quoted rate higher than L1 Bidder | |
| 4 | L4₹33.8 L+₹2.8 L (8.92%)Rejected-Finance RAM JANAKI THAKURBARI J T ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | L4 | Rejected-Finance Quoted rate higher than L1 Bidder | |
| 5 | L5₹35.5 L+₹4.5 L (14.4%)Rejected-Finance | L5 | Rejected-Finance Quoted rate higher than L1 Bidder |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
16 Jun 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 137 WE PIN 914 137 C O 99 APO
SPECIAL REPAIR TO BLDG NO T 35 IN J ZONE AT RANGAPAHAR MILITARY STATION
2020_MES_345656_1
8438/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Class D Category a i
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹77,600
Yes
13 Aug 2020
18 May 2020
18 Jun 2020
18 May 2020
16 Jun 2020
2 Jun 2020
60 days
Amount
Dismantling of AC (corrugated, semi corrugated etc) roof sheets including ridge and valley etc as in roof covering and removing unserviceable materials from site of work complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of reed, lathing, single or double including battens and plaster or chicken wire lathing and removing unserviceable materials from site of work complete all as directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position in unframed work and removing materials from site of work complete all as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc.15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed.
Taking down wooden chowkats or frames with shutters with n.exc. 1.50 Sqm each (without taking of shutters from the frames) complete all as specified and as directed.
Taking down wooden chowkats or frames with shutters with exc. 1.50 Sqm but n.exc. 4 Sqm each (without taking of shutters from the frames) complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed
Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed.
Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed.
Supply and fixing 4 mm thick size 600 x 600 mm HPSC (High pressure Steam Cured) pre-primefered self embossed texture designer board E-board classic to be fixed with and including anodized aluminium grid / section of size 605 mm x 605 mm with main runner 38 x 24 x 0.90mm thick, cross tee 28.6 x 24 x 0.9 mm and wall angle 19 x 19 x 0.9 mm duly suspended with 2 mm dia GI wire hanger 1200 mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed.
Fixing only old textured designed board E board classic to alluminium grid complete complete all as specified and directed. (Note: Materials retrive from item No. 2 here-in-before shall be reused)
Material and labour for non skid ceramic joint free coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm shall be laid on floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour / shade / matrix of tiles over and including 15mm thick screed bed / bedding layer in CM (1:6) complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm shall be laid on wall / column / vertical surfaces as in dado / skirting set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour / shade / matrix of tiles over and including 10mm thick cement plastering / backing coat in CM (1:4) complete all as specified and as directed.
Material and labour for non skid ceramic joint free coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm shall be laid on floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour / shade / matrix of tiles over and including 15mm thick screed bed / bedding layer in CM (1:6) complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm shall be laid on wall / column / vertical surfaces as in dado / skirting set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour / shade / matrix of tiles over and including 10mm thick cement plastering / backing coat in CM (1:4) complete all as specified and as directed.
Materials and labour for 15 mm thick rendering on one side of lathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Materials and labour for rendering 15mm thick plaster in cement mortar (1:6) on the other side of lathing finished even and smooth without using extra cement complete all as specified and as directed.
Supply and fixing 0.71 mm dia wire netting of galvanised steel wire of size 12 mm mesh and fixed with tinned tack of wire staples complete all as specified and as directed.
Supply and fixing well-seasoned 2nd class hard wood as in scantling, clean sawn, timber framed and fixed complete all as specified and as directed.
Material and labour for rolled mild steel for roof trusses ( framed), trussed, purlins, crane grantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Supply and fixing anodised alluminium frame for door, window, ventilator with one or more rebate including jointing cleat for fixing complete all as specified and directed.
Supply and fixing anodised aluminium window and ventilator shutters, side hung type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
Supply and fixing anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprine packing, Handle -02 Nos in each door, hinges, anodised aluminium snap beading, screws, mortice lock with minimum 03 sets of key etc complete all as specified and directed.
Supply and fixing in repair for aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
Supply and fixing framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted or forged into spikes ; window framed gurad bars ; barred iron doors, laddrs, framed balasters, walk ways, railings framed work of water and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Materials and labour for half brick thick brick work with sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed.
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 15 mm thick rendering cement plaster on other than fair faces of brickwork or concrete surface on wall / column / vertical surfaces in cement mortar 1:6 and finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for 15 mm thick rendering cement plaster on fair faces of brickwork or concrete surface on wall / column / vertical surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for 40 mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in floor, finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channel and like etc complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm from item No. 38 above. (For adjustment only)
Supply and fixing sexcond class hardwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed.
Material and labour for complete removal of existing treatment from old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint in any tint over a coat of pink primer including preparation of surfaces complete all as specified and directed.
Material and labour for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamal paint complete all as specified and as directed.
Materials and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Materials and labour for preparation of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after complete removal of existing treatment complete all as specified and as directed.
Materials and labour for preparation of old decorated wall surfaces by brooming down with steel wire brush and applying one coat of oil bound distemper complete all as specified and as directed.
Materials and labour for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Materials and labour for preparation of old plastered surfaces of walls and applying two coats of cement base paint over a coat of primer after complete removal of existing treatment complete all as specified and as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, (including unscrewing from boards/out-let boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.), removing materials off the site of work and making good disturbed surfaces of walls, floors, etc.all as directed.
Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuity wire connected to common earth dolly drawn through and including PVC casing caping of adequate size with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
.-Ditto- all as per item No 51.00 here-in-before but for 3 pin 6 amps switch socket outlet on the independant board with 1.5 Sqmm cable and -ditto-.
.-Ditto- all as per item No 51.00 here-in-before but for 3 pin 6 amps switch socket outlet on the same board with 1.5 Sqmm cable and -ditto-.
.-Ditto- all as per item No 51.00 here-in-before but for one 3 pin 16 Amps switch socket combination on independent board with 2.5 sqmm PVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor and -ditto-.
Supply and fixing Piano switch flush button single pole one way 6 Amps complete all as specified and as directed.
Supply and fixing socket outlet 5 pin, 6 Amps, 230 volt flush type complete all as specified and as directed.
Supply and fixing switch socket combination 2 in 1, 6A/16A, 5 in 1 flush type complete all as specified and as directed.
Supply and fixing fan regulator 100/120 watt step type AC 220 Volt complete all as specified and as directed.
Supply and fix ceiling rose surface Polycarbonate/ PVC three terminal complete all as specified and as directed.
Supply and fix Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts including taking down old unserviceable Sheet metal enclosure alongwith MCB complete all as specified and as directed.
Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 10 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 10 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Casing Caping of adequate size with all accessories including taking down existing burnt sub main wiring complete all as specified and as directed. Note : Three runs of 10 Sqmm cable and one run of Casing Caping shall be measured as one unit for payment purpose.
Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Casing Caping of adequate size with all accessories including taking down existing burnt sub main wiring complete all as specified and as directed. Note : Three runs of 6 Sqmm cable and one run of Casing Caping shall be measured as one unit for payment purpose.
Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Casing Caping of adequate size with all accessories including taking down existing burnt sub main wiring complete all as specified and as directed. Note : Three runs of 4 Sqmm cable and one run of Casing Caping shall be measured as one unit for payment purpose.
Supply and fixing in replacement 20 watt LED, 4 feet long, wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and electronic driver etc with all accessories, internally prewired and fixing the same on and including two Nos. PVC blocks and connecting up with flexible copper cable of size 0.75 Sqmm 3 core from ceiling rose to the light fittings includiong taking down old unserviceable light fitting complete all as specified and directed. (Make: Cat No. LHFXCEP1TNNW020 for batten and LHDLEFXD5LR020 (LED Tube) of Havells or equivalent model of Bajaj / Philips)
Supply and fixing in replacement 9 watt LED 2' wall mounted polycarbonate batten internally prewired with electronic driver and polycarbonate diffuser and fixing the same on and including two Nos. PVC blocks and connecting up with flexible copper cable of size 0.75 Sqmm 3 core from ceiling rose to the light fittings including taking down old unserviceable light fittings complete all as specified and directed. (Make: Cat No. LHEXBQP5IN1W009 of Havells or equivalent model of Bajaj / Philips)
Supply and fixing for lamp holder , PVC / Polycarbonate type with PVC round / square block with and including 9 watt LED lamp suitable for lamp holder fittings including taking down old unserviceable one complete all as specified and as directed.
Supply and fixing LED 1 x 20 watt security light fittings drawn through and including GI bracket of 25 mm bore, light grade, 1.20 metre long, bent to shape and fixed on wall with 02 Nos metal fashener, 10 mm size including drilling hole as requirred and connecting up with flexible copper cable of suitable size from ceiling rose to the light fittings including taking down old unserviceable one complete all as specified and as directed. (Make: Cat No. LHETBXU7PA6S020 of Havells or equivalent model of Bajaj / Philips)
Taking down ceiling fan carefully of any sweep from its original position, dismantling the complete fan, cleaning all dust particle, applying grease for bearing, applying spray painting of synthetic enamel paint of supirior quality including filling up cavities with filler, reassembling the fan and blades and hanging the fan in same position and testing on completion complete all as specified and directed.
Taking down exhaust fan carefully of any size from its original position, dismantling the complete fan, cleaning all dust particle, applying grease for bearing, applying spray painting of synthetic enamel paint of supirior quality including filling up cavities with filler, reassembling the fan and blades and refixing the fan in same position and testing on completion complete all as specified and directed.
Material and labour for rubber bush with clamp set comprising GI nuts, bolts, washers and split pin complete all as specified and directed.
Material and labour for replacement of capacitor 2.5 MFD including making electrical connection complerte all as specified and directed.
Material and labour for replacement of steel ball bearing / bush of suitable size complerte all as specified and directed.
Material and labour for rewinding existing ceiling fan with suitable gauge of copper wire complerte all as specified and directed.
Material and labour for rewinding existing exhaust fan with suitable gauge of copper wire complerte all as specified and directed.
Supply and fixing DPX 4 way MCCB Distribution board, double door type , sheet steel. Powder painted, with bus bar, neutral link & earth bar etc and fixing MCB of various rating capacity including taking down old unserviceable DB alongwith MCCB and MCBs complerte all as specified and directed.
Supply and fixing DPX thermal magnetic MCCB of 160 A, 4 pole of 50 KA, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complerte all as specified and directed.
Supply and fixing as in replacement MCB DB SPN 8 ways, powder coated, double door, 230 Volts, including bus bar neutral link, earth bar and din rail, for fixing MCB of various rating including taking down old unserviceable DB alongwith MCBs complete all as specified and as directed.
Supply and fixing MCB 6-32 Amps, SPN, 230 Volt "C" series, breaking capacity 10 KA, suitable for fixing in MCB DB complete all as specified and as directed.
Supply and fixing MCB 6 - 32 Amps, SP, 230 Volt "C" series, breaking capacity 10 KA, suitable for fixing in MCB DB complete all as specified and as directed.
Supply and fixing MCB 40 Amps, SP, 230 Volt "C" series, breaking capacity 10 KA, suitable for fixing in MCB DB complete all as specified and as directed.
Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up/down unserviceable pipe complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. (Note: Earthwire upto 7.50 m from earthplate shall be measured and paid in the quoted rate)
Supply and fixing 42 watt LED 2' x 2' recess mounting ceiling light fitting extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver with all accessories iternally prewired and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to light fittings including taking down old unserviceable light fittings complete all as specified and directed.
Taking down existing DPX 4 way MCCB DB alongwith all existing accessories and MCBs, MCCBs etc and refixing the same at other location complete all as specified and directed
Taking down existing MCB DB 4 way / 8 way alongwith all existing accessories and MCBs etc and refixing the same at other location complete all as specified and directed
Taking down existing mirror light fittings after disconnecting all electric connection and refixing the same at other location and making necessary electrical connection complete all as specified and directed
Taking down existing ceiling light fittings of various capacity after disconnecting all electric connection and refixing the same at other location and making necessary electrical connection complete all as specified and directed
Taking down existing window type AC upto 2.00 TR capacity from the installed position, dismantling complete unit, applying blower to remove the compete dust, cleaning all the components with suitable cleaning agent, combing the condenser coil for better efficiency and re-assembling the complete unit after re-installing in its original position and testing on completion complete all as specified and directed
Taking down existing outdoor unit of split type AC upto 2.00 TR capacity from the installed position, dismantling complete unit, applying blower to remove the compete dust, cleaning all the components with suitable cleaning agent, combing the condenser coil for better efficiency and re-assembling the complete unit after re-installing in its original position and testing on completion complete all as specified and directed
Taking down existing indoor unit of split type AC upto 2.00 TR capacity from the installed position, dismantling complete unit, applying blower to remove the compete dust, cleaning all the components with suitable cleaning agent, combing the condenser coil for better efficiency and re-assembling the complete unit after re-installing in its original position and testing on completion complete all as specified and directed
Material and labour for gas charging of R-22 refrigerant and filling up to the window / split type AC complete all as specified and directed,
Shri Atoshe Tuccu
sanjay kumar
SHRI BANARSI PRASAD
M/S MUGHATOLI AYE
PERFECT BUILDERS AND SUPPLIERS
Feroz Alam Khan
SHRI VIKASHE ZHIMOMI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .