Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹16.5 L+₹1.1 L (6.87%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹17.8 L+₹2.4 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹19.4 L+₹3.9 L (25.3%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹20.1 L+₹4.6 L (29.9%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L5 | Rejected-Finance Being 5th lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
REPAIR / MAINT TO PERIMETER, EXTERNAL LIGHTS AND OTHER CONNECTED ITEMS AT AF STN SARSAWA UNDER GE(AF) SARSAWA
REPAIR / MAINT TO PERIMETER, EXTERNAL LIGHTS AND OTHER CONNECTED ITEMS AT AF STN SARSAWA UNDER GE(AF) SARSAWA
2022_MES_530488_3
8122/SAR-22/2022-23
Open Tender
Civil Works
Item Rate
333 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹50,000
Yes
3 Oct 2022
30 Aug 2022
20 Sept 2022
30 Aug 2022
13 Sept 2022
30 Aug 2022
Amount
Repair and maintenance of street light/security lights/flood lights installed at various locations of domestic area by removing the lights from pole/bldg or any other place where ever is installed, throughly checking, cleaning of the glass/ acrylic covers and make them serviceable by removing/repair of unsv parts and refixing the same at original place complete all as specified and directed. Note :- (i) Replacement of the parts shall be measured and paid seperately. (ii) Contractor will provide 20 mtr height ladder/hydra to make hanger LED light servicable.
Supply & fixing of LED aviation light yellow painted die cast aluminium alloyl housing with five parellel circuits max 12 watt consumption with all accessories with and including one LED lamp 12 watt after taking out light fittings as existing at site complete all as specified and directed.
Supply & fixing of LED driver suitable for LED street light fittings 45 to 60W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED street light fittings 70 to 90W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED Flood light fittings 150W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED Flood light fittings 200W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply and fixing 60 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy , cast alluminium alloy housing IP 66 protection, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95,, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED Toughned glass with five year menufechar warranty certificate only with name of manufacturer / logo clearly embossed on housing of every fitting, , including taking down existing light fittings complete all as directed and specified.
Supply and fixing 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy, cast alluminium alloy housing IP 66 protection, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED,Toughned glass with five year menufechar warranty certificate only with name of manufacturer / logo clearly embossed on housing of every fitting, including taking down existing light fittings complete all as directed and specified.
Supply and fixing 120 watt LED Flood Light fitting with not less than 110 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, taughned glasss with secondory peanut lenses, potted driver input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, , having name of manufacturer and logo embossed on housing of each light fitting, with five year manufacturer warranty certificate including taking down existing light fittings all as specified and directed.
Supply and fixing 150 watt LED Flood Light fitting with not less than 110 lumen / watt delivered lumen efficacy, cast aluminium alloy housing IP 66 protection, taughned glasss with secondory peanut lenses, potted driver input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, having name of manufacturer and logo embossed on housing of each light fitting, with five year manufacturer warranty certificate including taking down existing light fittings all as specified and directed.
Supply and fixing 200 watt LED Flood Light fitting with not less than 110 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, taughned glasss with secondory peanut lenses, potted driver input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, including taking down existing light fittings with five year manufacturer warranty certificate all as specified and directed.
Supply and fixing 250 watt LED Flood Light fitting with not less than 110 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection,taughned glasss with secondory peanut lenses, potted driver input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, year manufacturer warranty certificate having name of manufacturer and logo embossed on housing of each light fitting, with five year manufacturer warranty certificate all as specified and directed.
S & F in replacement of timer switch for security lights duly enclosed in suitable enclosure with locking arrangement. Fixed to wall/pole by means of clamp, nut, bolt and washers etc incl for comprising the following items :- (a) MCCB 63 A 16 KA 4 pole - 01 No (b) MCB SPN 5 - 30 Amp - 01 No . (c) Power contactor ML-3, 3 pole- 01 No . (d) Timer switch analog dial type -01 No. (e) By pass arrangement for testing/repairing the lights
S&F in replacement multi stranded copper cable PVC insulated sheathed 1100 volts grade of size 2.5 sqmm 3 core, drawing through tubular pole and GI brackets etc upto LED light and making connections and testing for functioning of light fittings complete all as specified and as directed.
M&L for PCC 1 : 2 : 4 type B1 Using 20 mm graded stone aggregate for copping of poles/stay/panal complete all as specified and directed .
S&F in replacement Non metallic Junction box made out of Thermoplastic size not less than 28 cm x17cmx10cm hinged with lockable arrangement including aluminium bus bar TPN capacity 200 Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed. Make : Hensel/Sintex
S&F in replacement Non metallic Junction box made out of thermoplastic size not less than 18 cm x10cmx8cm hinged with lockable arrangement including aluminium bus bar SPN capacity 100Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
Supply & fix Decorative LED Post Top Lantern light fitting with max. system wattage 40 watt and system lumen output not less than 100 lumen per watt, total system lumens not less than 3600 lumens, PF not less than 0.95, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of 40 watt solar street light fitting complete with GI pipe med grade 50 mm bore 20 feet long grouted in PCC , with not less than 125 lumen / watt delivered lumen efficacy , total system lumens not less than 5000 lumen,solar PV module should be 12V 60W-Mono-crystalline & solar charge controller should be MPPT & its capacity not less than 12V,6A with battery (LiFeP04) with BMS 12.8V 24 Ah & its back up should be 2 days with dimming & its life span must be more than 50000 hours all as specified and directed.
Repair/rewinding of high mast motor 0.75HP by dismantling of mast assembly from pole with manually & checking of all parts & control wiring from control gear box to fitting at site. Lifting of mast assembly with help of motor after proper rewinding/repair/greasing of motor complete all as specified and directed.
S&F LED driver suitable for 10 watt led garden light including taking out old driver with LED complete with all as specified and directed. Driver should be same make as installed as before in Led light fitting.
Supply and fixing in replacement LED strip light of colour as directed by Engr-in-charge.
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed. Make : Kinjal/Steel grip
Supply only 25 mt long 2.5 cm wide and at least 0.200mm wall thickness HT tape with adhesive of good quality all as specified and directed. Make : Kinjal/Steel grip
Supply and fixing in replacement of flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure all as specified and directed by Engr-in-charge.
Supply & fix in replacement of flame proof LED flood light luminaries 120 watt comprising of body made in cast alluminum alloy LM6 construction luminaries spun alluminium reflector fitted inside main body main body, heat resistant toughend glass cemented to cast aluninuuim, retainging ring fixed to main body , mounted on MS galvanised iron cradle and base plate for rotating in horizontal and vertical planes, voltage 140-270,IP 65 , main connector suitable up to 6 Sqmm incoming cable, terminal enclosure plain covers are fixed by means of socket head allen cap stainless steel screw, conforming to standard IS/IEC 60079-0-2004, IS/IEC 60079-1-2007 , earthing with internal 1 No., external 2 Nos on main Enclosure M6x 12 MS screw & plain washer all as specified and directed by Engr-in-charge.
S&F in replacement of sub main wiring with single core PVC insulated and unsheathed 1100 volt grade (FRLS) electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof conduit fittings and accessories such as tees junction boxes, bends and including drawing continuous earth wire PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge. Note : 3 - run of 2.5 sqmm wire and 1- run of ERW steel conduit shall be measured as one run.
Supply and fixing in replacement of power contactor type ML-3 , 3 pole suitable for street light timer panel complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Timer clock analog dial type suitable for street light timer panel complete all as specified and directed by Engr-in-charge.
Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for taking out/laying of U/G HT/LT cable and getting out the excavated soil including triming the sides complete all as specified and as directed
Returning, filling in, incl spreading leveling, watering and well raming in layers not exc 25 centimetre thick in layer in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed Engr-in-Charge.
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
Material and labour for Sand cushioning with layer of fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed.
Supplying, laying, jointing & testing in replacement of LT cables XLPE insulated, PVC sheathed aluminium conductors multistranded armoured heavy duty 1100 volt grade cross sectional area 06 sqmm 4 core laid in trenches/ducts/along poles/through pipe under road complete all as specified and as directed.
All as per item No 35 above but size 10 sq mm 4 core complete all as specified and as directed
All as per item No 35 above but size 16 sq mm 4 core complete all as specified and as directed
All as per item No 35 above but size 25 sq mm 4 core complete all as specified and as directed
Supply and laying in replacement double walled corrugated HDPE duct pipe of 40 mm outer dia confirming to IS 14930 Pt II with antirodent and non flame propergating properties of approved colour complete with fitting for cable protection complete all as specified and as directed.
S&F in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
S&F in replacement street light bracket made out of light grade GI pipe 40 mm normal bore of 1.2 mtr long tilted 30 degree angle on 0.4 metre length along with flat iron clamp of 40 x 4 mm size 750 mm long duly drilled made to shape the bracket with nut, bolt and washer including applying two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of LED Food light of capacity 50 Watt, IP 65, rated voltage 220V-240V AC/ 50 Hz of desired colour as directed, including taking down old unsv light complete all as specified and directed by Engr-in-charge.
S&F in replacement 10 watt led bollard light system lumen output not less than 80 lumen per watt, total system lumens not less than 3200 lumens, PF not less than 0.90, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, ,input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution including taking out old any type light complete with all as specified and directed.
Supply and fixing in replacement of Automatic street light switch using infrared sensor based nature switch for automatic switching of street light, nature switch operating should be based on nature switch lux level required luminaire level for switching on is < 30 and for switching off >10 Lux . The sensor alongwith suitable power contactors , incoming outgoing MCBs should be enclosed in a pole /wall mountable enclosure made rust proof , electric shock proof , termite proof, and FR grade SMC junction box conforming to IP 54. Timer should also have provision of auto/ manual toggle switch. The circuit should be suitable to the three phase load of 6 KW with contactors (3 Nos) & incoming- outgoing MCBs (3 Nos each) rating of 20-25 Amps & circuit wiring of minimum 10 Sqmm complete all as specified and direcetd by Engr-in-charge.
Sharma Electrical and Engineering Works
PANWAR CONSTRUCTIONS
NAQLI LAL SHARMA AND ARUN SHARMA
VIJAY ENTERPRISES
ISHWAR ELECTRICALS AND PROCESS SERVICES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .