Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.1 L+₹3.4 L (14.6%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹29.4 L+₹5.7 L (24.0%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹31.3 L+₹7.6 L (32.2%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹33.3 L+₹9.6 L (40.6%)Rejected-Finance POCKET A 2 310 SECTOR 08 ROHINI NEW DELHI 110085 | NEW DELHI | NORTH WEST DELHI | DELHI | 110085 | L5 | Rejected-Finance Rejected |
Tender Value
₹35.2 L
EMD Value
₹70,340
Closing Date
22 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Subroto Park
GE AF Subroto Park c o 56 APO
ADDN/ ALTN TO P-284 (CAPS) AT CAMERO COMPLEX UNDER GE (AF) SUBROTO PARK
2022_MES_541341_1
GE/SP/ TOKEN-25/2022-23
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF Subroto Park
₹70,340
Yes
12 Oct 2022
27 Jul 2022
29 Aug 2022
27 Jul 2022
22 Aug 2022
10 Aug 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M&L for vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed bed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed by Engr-In-Charge.
All as above item No-2 but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and as directed by Engineer-in-Charge.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles in vertical surface 300x450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed in cement 1 :4 and pointed in white or coloured cement to match the shade complete all as specified and directed by Engineer-in-Charge.
Dismantling of structural steel work including doors, gates, grills but excluding framed trusses making good in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each making good in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5Sqm but not exc 4.00 Sqm each complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) frame for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type three track, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc complete all as specified and as directed by Engr-In-Charge.
S&F for powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) alumonium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all aspecified and directed by engr-In-Charge.
S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc complete all as specified and directed by Engr-in-Charge.
S&F Aluminium(extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as directed and specified.
S&F brass body Mortice lock, vertical type,size 100 mm 4 lever, incl escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.
S&F in repairs for double action floor spring hydraulically regulated mode lap of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed by Engr-in-Charge.
S & F in repair 150mm long floor door stopper of aluminium alloy and tongue with hard drawn steel spring complete all as specified and as directed by Engineer-in-Charge.
M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification and directed by Engr In Charge.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face complete all as specified and directed by Engr In Charge.
S&F in repair 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete and specified and directed by engr-in -charge.
S&F 150mm long aluminium handle cast type polished bright complete and specified and directed by engr-in -charge.
S&F 100 mm long butt hinges medium weight, stainless steel, and fixed complete all as specified and directed by engr-in -charge.
S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved over 50mm thick sand cushioning and 100mm thick plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping including dismentling complete all as specified and directed by Engineer-in-Charge.
S & F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, collapsible gates, frame work of water tanks and similar work conforming to E-165 (Fe-290) complete all as specified and directed by Engineer-in-Charge.
M&L for Chequered cement concrete coloured tiles (300 X300) 25mm thick confirming to IS -1237 (rubber moulded gloushy finshed) in floor setc, set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) including 100mm thik cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete all as specified and directed by Engr In Charge.
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco, Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls and including dismentling complete all as specified and directed by Engr-in-Charge.
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and directed by Engineer-in-Charge.
Dismantling stone slab and granite of any description or thickness in floors etc and removing the debries outside the MOD land complete all as specified and directed by Engineer-in-Charge.
M & L for 15 mm thick screed bed or bedding layer of cement mortar (1:4), for laying of granite complete all as specified and directed by Engr In Charge.
M&L for pure black Granite (of any type) tiles 20mm (+-2mm) thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including moulded ofnedges grinding and polishing complete all as specified and directed by Engr-in-Charge.
M&L for anti skid brass 8-10mm solid rail in stairs case in tripple layer in between the 8-10mm gap in each case complete all as specified and as directed by Engr In Charge.
S&F in repairs Vitreous China wash basin white oval shape counter top of size 630x450mm including all fitting like CP pillar tab swan neck, pvc connection, CP waste coupling 32mm size half threaded with 130mm height complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 32mm dia Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed by Engineer-in-Charge.
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with automatic sensor flushing system, with grating and union for discharge pipe including flushing cistern, flush pipe and waste pipe including providing and fixing plugs, bedding urinal aginst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screw, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, gratting and Union for discharge pipe complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exc 500 but not exc 1000 ltrs capasity and removing to store creditcomplete all as specified and directed by Engr In Charge.
S & F rotational moulded polyethylene water tank 1000 litre capacity tripple layer (white colour) (cylindrical vertical with closed top) hoisted and fixed as specified in SSR Part-I complete all as directed at site.
S&F 20 mm bore Gun Metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repairs 15 mm bore angle valve chromium plated with wall flange and fancy type with high pressure screwed down with CP flange. Make- ORM- 10053 of Jaquar or its equivalent Parco/Marc complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, jet spray, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve foat and handle including brackets 10 litres complete all as specified and directed by Engineer-in-Charge.
S & F in repairs long body bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle screwed down for 15mm bore pipe complete.make -CON -037KKN of Jaquar or equivalent/GEM/PARKO.
S & F in repairs CP Soap dish of Make-AQN-7731 of Jaquar or equivalent MARC/GEM/PARKO complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 15mm bore two way angle valve chromium plated with wall flange and fancy type high pressure screwed down with CP flange complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PTMT grating round of 100mm dia (Miniumum wt 50gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in reapirs PTMT grating with waste hole (Minium wt 100 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in repiar CP connection 15mm size for Hot & Cold water with CP nuts of length 450mm long all as specified
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed including taking down complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 51 above but 15mm bore .
Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth including water proofing compound ( without using extra cement) complete all as specified and directed by Engineer-in-Charge. Note:- Water proofing compound shall be measured & paid seperately.
M&L for rendering in CM (1:4) 15 mm thick on fair faces of brick surfaces or concrete surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering in CM (1:3) 5 mm thick on concrete surfaces of ceiling, even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound only complete all as specified and directed by Engr-in-charge.
Dismantling loose concrete cover of RCC columns, beams, slabs chajjas and the like as directed, roughening and cleanining concrete surface with steel wire brushes, washed with water and allowed to dry, incl derusting of steel reinforcement, providing fabric mild steel wire mesh 75 mm x 75 mm x 2 mm dia as reinforcement to concrete. After placing the additional reinforcement all concrete surfaces shall thoroughly scrubbed with brushes, washed with water and alloy to dry . To this surfaces apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mmj thick (average thickness ) gunniting mix (using 1 part of ordinary Portland cement 53 Grade and 2 parts of ghaggar sand mixed with adhessive / admixture at the rate as directed) with a pressure of 2 to 2.5 Kg per Sq cm by gunniting machine and surfaces finished even and fair, incl necessary padding, shuttering / form work and 15 mm thick cement plaster in CM (1: 4 ) complete all as specified and directed by Engineer - in -charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick wall care putty on wallscomplete all as specified and directed by Engineer-in-Charge.
M&L for preparation on new or previously untreated wall and applying two coats of weather coat over 3mm wall care putty over priming coat of exterior primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing and 3mm wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
Material & Labour for prepration of old plastered or previously untreated wall and applying two coats of weather coat over 3mm wall care putty over priming coat of exterior primer complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in sunken portion in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
M&L for providing and making fillet of 75mmx75mm in size with cement concrete in 1:2:4 in sunken portion, complete all as specified and directed by Engineer-in-Charge.
M&L refilling lime concrete with brick aggregate (Course) in lime mortar1:3, in the sunken with the help of proper tools & equipments & plants complete all as specified and as directed by Engineer-in-Charge.
M&L Providing and making fillet of 75mmx75mm in size with cement concrete in 1:2:4 in sunken portion, including applying the under mentioned course of sunkan treatment complete all as specified and directed by Engineer-in-Charge:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered surface.(b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.(c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqmpolysternon woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The overlap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.(d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame complete all as specified and directed by Engr In Charge.
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed by Engr In Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, built in 1:4 cement mortar complete all as specified and as directed by Engr-in-Charge.
M&L for brick work with subclass B bricks, staright or curved on plan on plan to any redius in half brick thickness wall, built in 1:4 cement mortar complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm dia bore PVC (SWR) bends, including removing for concrete and refixing with 1:2:4, type B1 (20 mm graded aggregate) or in 1:3 cement mortar complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) 110 mm dia bore pipe single socketed, in any length with rubber ring joints fixed to walls, including necessary PVC clamps for fixing of pipes and dismentling complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC Type B-2 (1:2:4) using 40mm graded stone aggregate) as in man hole, surface channel and drain complete including finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitered / stopped ends etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power) complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core FRLS PVC insulated unsheathed IS-694 marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through and including conduit of size of not less than 20mm including all acessories concealed wiring in wall and surface of ceiling terminated in and including ms sunken box covered with3 mm thick laminated top sheet cover along with provn of earth wire PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS IS - 694 markd copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. (Note : Cost of for cutting chaising and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.) of the followings:- (a) One light point controlled by one switch one way.
(b) One C/ fan/Exhaust fan/wall fan point controlled by one switch one way.
(c )For one 3 pin 5 amps socket outlet on independent board.
(d) For one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 77 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Fan step regulator, 120W - 2 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush 3 modulebox Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush 4 modulebox Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush 6 modulebox Complete all as specified and directed by Engineer-in-Charge.
S & F Modular white cover plate with frame 3 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular white cover plate with frame 4 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular white cover plate with frame 6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate body Complete all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp Complete all as specified and directed by Engineer-in-Charge.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed 1100V cable copper conductor of size 04 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded 1100V copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete. Note - 3 run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit lenght.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed 1100V cable copper conductor with size 06 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded1100V copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete. Note - 3 run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit lenght.
S&F of LED ceiling light 36 watt 2'x2' recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Taking down existing wall mounting fan any size and refixing the same with fixture arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F wall mounting fan 400 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscilation switch and tilt mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Taking down fan, sealing cable end,dismantling blades and removing fan and blades from site and depositing in MES store
Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m
Supply and fix vertical distribution board made out of CRCA sheet, double door, fixed flush in wall TPN 8 way 415 volts having 200 Amps rated bus bar and dust and vermin proof suitable for MCCB as incomer and MCB as outgoing complete all as specified and as directed by Engineer-in-Charge including cutting chases in walls for fixing DB and making good the disturbed wall surface to match with existing specification. Note :- MCCB/MCB shall be measured and paid seperately.
Supply and fix MCB distribution board with Bus bar 200A, neutral link & earth bar made out of CRCA sheet fixed flush in walls mounting SPN 12 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge including cutting chases in walls for fixing DB and making good the disturbed wall surface to match with existing specification.
S & F of MCCB 3 pole 415 V, adjustable type 125 amps with breaking capacity of 16 KA all as specified and directed by Eng in charge.
Supply and fixing MCB, single pole, 240 volts, 6 to 32 amps C Curve having breaking cap 10 KA.
Supply and fixing MCB single pole, and neutral, 240 volts, 40 amps C Curve having breaking cap 10 KA.
Disconnecting electrically dismantling and taking down distribution board any type and size incl removing from site and making good disturbed wall surface to match existing specification
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below groundlevel) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Notes :- (i) GI strip connecting upto test point is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto test point.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire
OMVIN ENTERPRISES LLP
J D ENTERPRISES
Mahesh Enterprises
M/s. Kansal Construction Co.
Ashish Sehgal and Co.
High Tech Metal India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .