Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.0 LAccepted-Finance | 1 | Accepted-Finance L1 firm | |
| 2 | 2₹7.7 L+₹1.7 L (29.2%)Accepted-Finance | 2 | Accepted-Finance Higher than L1 | |
| 3 | 3₹19.8 L+₹13.9 L (232.7%)Accepted-Finance | 3 | Accepted-Finance Higher than L1 |
Tender Value
Refer Docs
Closing Date
25 Apr 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DTO CGDHQ-11
CGDHQ-11 Bogmalo Post Chikalin Goa
Defect rectification on various equipment
2022_ICG_518374_1
D-11/S-Prahari/MW-02/22-23 dated 15 Apr 22
Limited
Miscellaneous Works
Lump-sum
60 days
CGDHQ-11 Bogmalo Post Chikalin Goa
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
28 Apr 2022
15 Apr 2022
26 Apr 2022
15 Apr 2022
25 Apr 2022
15 Apr 2022
15 Apr 2022 - 25 Apr 2022
90 days
DEFECT RECTIFICATION ON VARIOUS HULL EQUIPMENT ONBOARD ICGS SAMUDRA PRAHARI AT GOA
H-1083:20 no’s Ship side scupper lips with movable type brackets and rubber lips and 12 in nos. goose neck flaps corroded/thinned down to be renewed as per sample alongwith Rubber padding of 12 in nos. goose neck flaps and ship side scupper lips. Mat of goose neck flaps- MS size- 270 mm dia x 04 mm) circular plate with rubber padding. Rubber padding of 12 in nos. goose neck flaps - Neoprene rubber of dia 270 mm x 03 mm thick. Flap securing butter fly nut/ bolt of flaps broken 08 butter fly nuts/ bolts to be renewed. Size of scupper- 200mmx 200mmx40 mm ,Rubber lip size- 200mmx 200mmx40 mm x 6 mm thick, Rubber grade- Nitrile rubber All in way Job involves removal of insulation and lagging and panelling from internal compartments.
H-1087:Air ventilation supply/ exhaust wire mesh and side frame at general compartments and MER, DG room perished/deteriorated. Wire mesh with side frames to be renewed. Size of the general compartments-500x 300 mm to varying size, 12.5 mm mesh, No- 25. Size and material of the MER and DG room Mat- MS frame, wire mesh size – 10 mm, total no-06 nos, Size as follow:- Sl no Grill size Compartment (i) 1100X900-02 No, MS frame -05 mm. DG room (ii) 600x 250 -02 no, Ms thick -05 mm. DG room (iii) 600x 600-01 no, MS thick -05 mm DG room (iv) 600x1300-02 no MS frame -05 mm. MER (v) 700x 800-02 no MS frame -05 mm. MER (vi) 800x1300-01 no MS frame -05 mm. MER (vii) 600x 1300-01 no MS frame -05 mm. MER (viii) 300 mm dia , 12.5 mm wire mesh , circular PC hold(f) & aft,-06 no
H-1088: 06 no galley grease filters (multiple layer wire mesh) perished and frames deteriorated. To be renewed as per sample. Size-400x 300 -04 nos, 300x 300-02 no.
H-1095:03 no’s Air Treatment Unit casing doors and 10 no’s inspection door openings with side frames on deck head related to ventilation trunks corroded/ perished To be renewed as per the sample. Mat and size of the inspection door- MS, size- 250 mm x 250mm x2 mm, Mat and size of ATU door –GI, Size-1000mmx625mm.
H-1194: Jr sailor, and officer’s scullery wash basin tray mess deteriorated and Sr sailor water cooler tap and tray to be renewed. Scope of work includes renewal of basin tray as per the sample. Qty- tray Mesh - 04 no’s, tap -01.
H-1195:02 in no’s mirror faded in Ship’s galley and Barber shop. Bar shop hydraulic chair cylinder oil leakage observed. Mirrors to be renewal as per the sample and chair cylinder to be repaired and proved.
H-1196:02 no’s rope reel plumber block bearings base and bearings corroded/ deteriorated. To be renewed as per the sample.
H-1198:04 Nos three seat sofa Rexene of Sr. sailor dining hall and domestic mess, Barber shop damaged. To be renewed as per sample. Job included: - (i). Renewed foam 30” x 30” x 4”. (ii). Renewed Rexene 1 mtr x 1 mtr.
H-1200:Gun deck, boat deck, helo deck and Gemini Deck railing corroded/ deteriorated to be repaired/renewed as per sample. Mtr-30 Mtr.
H-1202:Jr. sailor scullery and engineering officer cabin wash room entrance metallic sheet corroded/deteriorated to be repair/replaced as per the sample.
H-1203:08 no securing belt for PC boat damaged/ perished. To be renewed. Length -10 M each, thick-8mm, width -50mm, 04 no securing lock & hook link also to be provided.
H-1204:15 no’s dressing line pulleys and securing brackets and 03 no’s halyard secure points deteriorated/ corroded to be renewed as per the sample.
OMKAR ENGINEERING WORKS
AMCOMS Enterprises
SHREE SALES AND SERVICES
OMKAR ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .