| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.5 L+₹57,880 (3.23%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹23.3 L+₹5.3 L (29.8%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance Being not L1 |
Tender Value
₹17.0 L
EMD Value
₹34,000
Closing Date
7 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVN OF WORK SERVICES FOR INSTALLATION OF KU BAND SATCOM AT EXISTING AFNET BUILDING AT TPS AF STN CHIMNEY HILLS
2023_MES_588573_4
82117/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) Chimney Hills Bangalore
As per tender document
7 documents required · 7 mandatory
₹500
AGE (I) (AF) Chimney Hills
₹34,000
30 Sept 2023
19 Jul 2023
9 Aug 2023
19 Jul 2023
7 Aug 2023
26 Jul 2023
19 Jul 2023 - 24 Jul 2023
Amount
Supply and fix Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 module upto 200 detector with suitable battery backup for 48 hrs in normal condition and 60 Minutes in alarm condition all as specified and as directed .
Supply and fix Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS: 11360 all as specified and directed
Supply and fix Addressable electronic sounder cum strobe all as specified and directed
Supply and fix Fire Cable,Red In colour with copper conductor PVC round sheathed (flexible) industrial cable of size 1.5 Sqmm,2 Core all as specified and directed by engineer in charge .
M&L for Point wiring with 2.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of 2.5 Sqmm as in phase/neutral and connected to common earth dolly on PVC Surface Box for fire panel drawn through open surface rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid on walls/ceilings all as specified and directed.
Supply and fix Switch -Socket Combination, 16 Amp,6 Pin,3 Module all as specified and directed .
Surface excavation in hard/ dense soil exc 30cm deep and avraging 15cm deep and getting out complete all as specified and as directed.
Removin excavated material (soils) to a distance not exc. 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed
M&L 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in paving including necessary form work complete all as specified and as directed.
TMTbar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate as in plinth base using 20mm graded stone aggregate set in cement mortar 1:4 complete all as specified and as directed.
M&L for 100mm thickness PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in paving etc complete all as specified and as directed.
M&L 50mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in paving including necessary form work complete all as specified and as directed.
Use and waste of formwork to sides of rough finished surfaces of flat concrete paving, plinth base; and similar work;vertical or to batter complete all as specifird and as directed.
M&L for forming 12mm thick expansion joints filled with per-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade'B' in 100mm thick concrete slab complete all as specifiede and as directed.
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified, erected in position and securing funners with holdfasts and brackets complete all as specifiede and as directed.
M&L for preparation of new surfaes of steel over 10cm width or girth and applying two coats of synlthetic enamel paint over a coat of red oxide primer complete complete all as specifiede and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core all as specified and directed .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core all as specified and directed .
Excavation in trenches not exc 1.5 m wide and not exc 1.5 min depth for laying of UG cable and getting out in hard soil all as specified and directed by engineer in charge. Note- Exacavation shall be done by Manual process.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of exacavated soil all as specified and directed by engineer in charge.
Supply and laying bricks of size 230 mm x 115 mm x 75 mm, sub class 'B' laid dry flat perpendicular to axis of cable for protecting complete all as specified and directed.
Supply and Spread natural riddled soil in trenches for cushioning and covering to cable complete all as specified and directed by engineer in charge.Note: (i) Natural soil shall be riddled by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 cm and 15cm after laying of cable. This is then gently punned down to a depth of 10cm above the top of upper-most cable. (ii) For the purpose of measurement only punned thickness only will be considered for payment.
M&L for cutting road / hard standing/Plith Protection to depth not exceeding 60 CM and to width not exceeding 45 CM for laying HDPE Pipes and making good the disturbed surfaces by 1:3:6 type C1 using 20 mm graded stone aggregate complete all as specified and as directed by Engineer in charge .
Supply and laying High density polyethylene pipes(HDPE) of 32 mm dia pressure rating 6 kgf/cm2 laid in trenches and fixed on poles all as specified and directed.
M&L Earthing complete with galvanised steel pipe electrode of size 40 mm bore,medium grade,2.5 meter length, burried directly in ground in bore 350 mm dia verticalIy to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead Strip 32 x6 mm by means with welded joints, bolts, nuts ,check nuts and washers protected by Gl light grade pipe of size 40 mm dia and connecting up with the DG Set as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, PCC Chamber, RCC Cover(Yellow painted) with handle , watering pipe 20mm dia GI Medium grade with funnel and wire mesh, Charcoal dust-80 Kg , salt-80 Kg ,Mild steel Earth marker with earthing result ,date all as per plate no.2 of SSR 1991 and as directed by Engineer in charge. Note:-Boring charges are included in the above quoted rates .
Supply, Install, testing and Commissing of Diesal engine driven generating set 20 KVA, 3 Phase, 4 wire, 415 volt, 1500 RPM, 50 HZ power supply with power factor 0.8, coupled directly to alternator mounted on a comman base plate complete with integral acoustic enclosures having salient features sauch as modular bolted construction with fabrication on imported CNC torrent punch machines, nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application / installation, intergrated design thereby facilitating / easy handing installation & shifting of the equipment at site. The design of integral acoustic enclosure should be of the type approved by national physical laboratory as per central pollution control-board (CPCB) latest norms/ regulation) with fuel tank of capacity 65 Litres, battery,Retrofit pollution control device and standred accessories and PCC foundation (acoustic enclosure also 30 CM above GL) as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specification:-
(A) ENGINE - Water-cooled diesal engine of 2 Cylinder, Minimum 25.5 BHP capacity under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to IS 6514. The engine shall consist of the following:- (i) Fly Wheel (ii) Flexible coupling with guard (iii) Cooling fan (iv) Raditor with guard and water pump engine (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Precision governor (mechanical type) (ix) Fuel filter (Mounted) (x) Lubricating oil filters (mounted) (xi) 12 V self regulating alternator belt driven by engine (xii) Exhaust silencer heavy duty residantial type (xiii) Corrosion resister / scale inhibitor (xiv) Starter 12 V DC (xv) Lubricating oil cooler (xvi) Lubricating oil Pump (Gear type) (xvii) Turbo Charger
(B) INSTRUMENT PANEL CONSISTING OF :- (I) Auto / manual starting switch with key (ii) lubricating oil temperature gauge (iii) lubricating oil pressure gauge (iv) Water temperature gauge (v) battery charging ammeter (vi) Battery charging indicating lamp (vii) House meter with RPM indicator (viii) Safty control against high tempreture of water (ix) Safty control against low lubricating oil pressure (x) over speed stop with double driven adaptor (C) BRUSHLESS ALTERNATOR (i) Alternator coupled to engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated baseframe suitable for mounting on a permanent foundation,brush less alternator shall be confirming to BS - 2613 or relevant IS - 4722. (ii) Type:Self- excited self regulated with autometic voltage regulator (iii) Rating:- 20 KVA at 0.8 PF lagging 4 Pole horizontal at NTP (iv)1500 RPM (v) System - 415 V + AC 3 phase 4 wire 50 HZ (vi) Connection - 4 wire star connected (vii) Enclosure - Screen projected drip proof (viii) ventilation - Self Ventilated (ix) Insulation - Insulation class H
Supply and fixing LED flood light 210 watt 230 V, AC,Total Lumens 2100 ,100 Lumens /Watt ,6500 K,outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed .
Supply and fixing TPN distribution boards protection ,class IP-43 ,Double door suitable for mounting MCCB 40 Amps,16 KA as incomer and TP MCB 10 Amps -01 Nos ,SP 10 Amps -02 Nos as outgoing with min 250 Amps rating bus bar TPN 04 way all as specified and directed by engineer in charge .Note- MCCB and MCB Rates shall be included in the above quoted rates .
M&L Earthing complete with galvanised steel pipe electrode of size 40 mm bore,medium grade,2.5 meter length, burried directly in ground in bore 350 mm dia verticalIy to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by means with bolts, nuts check nuts and washers protected by Gl light grade pipe of size 15 mm dia and connecting up with the DB as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, PCC Chamber, RCC Cover(Yellow painted) with handle , watering pipe 20mm dia GI Medium grade with funnel and wire mesh, Charcoal dust-80 Kg ,Salt-80 Kg ,Mild steel Earth marker with earthing result ,date all as per plate no.2 of SSR 1991 and as directed by Engineer in charge.Note:-Boring charges are included in the above quoted rates .
M&L for Point wiring with 2.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of 2.5 Sqmm as in phase/neutral and connected to common earth dolly on independent IP-55 Plexo Box with PVC Membrane board for flood light drawn through open surface rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid on walls/ceilings all as specified and directed.
Supply and fix Switch piano, flush type single pole, one way 15 Amp all as specified and directed .
Material and labour for corrosion resistant earthing system complete comprising of the following items:- (a) 17.2 mm dia, 3mtr length, Low carbon steel earth electrode with minimum 250 micron copper bonding certified by CPRI. (Copy of CPRI certificate to be submitted. (Dia of the rod & control number allotted to the manufacturer should be embossed on the rod and certificate from the same manufacturer shall be submitted along with the material.) (b) 25 kgs of earth enhancement material, environment friendly backfill compound. (c) Rust & weather proof heavy duty FRP earth pit chamber with dimensions 254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). (d) Exothermic welding set (e) Provision of one copper bus bar near tapping point for connection complete all as specified and directed by Engr-in-Charge. Make : CAPE/JEF/ ABB Furse. Note 1: The earthing description as mentioned above shall be read and followed strictly complete as per IS 3043 Code of practice for earthing. Note 2: Back-fill earthing enhancing compound should have a resistivity of less than 0.12 Ohm Mtr, should be electronically conductive (Like in metals) and should not depend on moisture for conduction and to be in dry form. Note 3: The material for earth enhancement material shall comply with clause 8.4.2 of National Building Code (NBC). Note 4: Back-fill compound should solidify when mixed with water, set like concrete and should not leach any chemicals into the ground. Note 5: Backfill compound shall be suitable to be used in either slurry or dry form and shall not be mixed with any soil / cement etc while pouring in the bore hole as per Clause 13.8 of IS 3043 Artificial treatment of soil so that it improves conductivity of the earth electrode and ground contact area.
Note 6: Backfill compound shall be tested as per IEC : 62561-7 and the test certificates Corrosion Test, Leach Test, Sulphur Test & Resistivity Test) to be submitted. Note 7: Backfill compound shall not depend on the continuous presence of water / moisture / salt to maintain its conductivity and shall not decompose or leach out with time. Note 8: Back fill compound shall contain a corrosion inhibitor to mitigate corrosion of copper and shall not contain hazardous chemicals. Necessary test certificate from NABL accredited Lab shall be furnished. Note 9: Backfill compound shall not be affected by drought, to be stable, suitable for any kind of soil and shall be stable between -10º C to 50º C temperature. Note 10: Backfill compound shall be supplied in sealed, moisture proof bags. These bags shall be marked with Manufacturer’s name or trade name, quantity, batch no & date of manufacture. Note 11: The earthing value should be constant upto 15 years from the date of installation. Certificate for the same to be obtained by the contractor from OEM and submitted to Engr-in-Charge before completion of work. Note 12: In case the value are not found within limit, i.e. 01 Ohm the same to be rectified by the contractor free of cost till 15 years. Important Note: Certain compounds dependent on moisture for their performance and needing water to obtain & maintain its beneficial characteristics shouldn’t be used as a back-fill material as it may not function well in dry environment.
Test Certificates : The following test certificates shall be submitted to Engineer-in-Charge prior to supply of materials:- (i) Certificate for the copper bonded electrode along with the control numberduly certified by CPRI. (ii) Short circuit withstanding capacity of the copper bonded rod from an independent laboratory (NABL Accredited Laboratory). (iii) Corrosion test certificate for the backfill compound from an as independent laboratory (NABL Accredited Laboratory). (iv) Leach test certificate for the backfill compound from an independent laboratory (NABL Accredited Laboratory). (v) Sulphur test certificate for the backfill compound from an independent laboratory (NABL Accredited Laboratory). (vi) Resistivity test certificate for the backfill compound from an independent laboratory (NABL Accredited Laboratory).
M &L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 X3 mm dia Copper strip wire all as specified and directed .
RAMESH BABU CO
rvelectricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .