Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC 1ST FLOOR SCO 35 CHAURA BAZAR ZIRAKPUR PUNJAB | BATHINDA | PUNJAB | 151001 | ₹42.6 L | L1 | Accepted-AOC EMD recovered from 1st RA SD amount. |
| 2 | L2₹47.8 L+₹5.2 L (12.1%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹47.8 L+₹5.2 L (12.1%) | L2 | Rejected-Finance Agency not Quoted lowest Price. |
| 3 | L3₹51.9 L+₹9.3 L (21.7%)Rejected-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹51.9 L+₹9.3 L (21.7%) | L3 | Rejected-Finance Agency not Quoted lowest Price. |
Tender Value
₹56.4 L
EMD Value
₹1.1 L
Closing Date
24 Oct 2023, 3:00 pmClosed
Sr. Manager (E-E)
SM Engg(E) , AAI, Electrical maintenance division Amritsar Airport.
Supply and Replacement of cooling Tower for 300 TR chiller plant at Amritsar Airport
2023_AAI_170143_1
AAI/ASR/Engg-E/eNIT-6/2023-24
Open Tender
Electrical Works
Works
120 days
SGRDI Airport Amritsar
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
₹1.1 L
13 Feb 2024
9 Oct 2023
25 Oct 2023
9 Oct 2023
24 Oct 2023
9 Oct 2023
9 Oct 2023 - 16 Oct 2023
Amount
SITC of FRP induced draft counter flow cooling tower each guaranteed to cool 1400 USGPM of water from 97.5°F to 90°F at a design wet bulb temperature of 83°F with FRP water basin, PVC fills with integral louvers and drift elimination, hot water distribution by gravity complete with statically and dynamically balanced axial flow, direct driven fans with TEFC induction motor suitable for operation on 415±10% volt, 50 Hz. AC supply, suction screen, make up with float valve and quick fill arrangement, overflow and drain connections, with necessary valves, suitable inspection ladders, access arrangement for cooling tower interior, steel supporting structure, anti-vibrating mountings, painting etc. complete as per specification. Heat Rejection capacity minimum 1325000 Kcal/hr (excluding concrete foundation).
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
350 mm dia.
200 mm dia.
150 mm dia.
100 mm dia.
80 mm dia.
50 mm dia.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.
100 mm dia.
Supply, Installation, Testing & Commissioning of following Valves, Strainers, in condenser water piping complete with companion flanges, nuts, bolts, gaskets, support etc and duly painted.
Butterfly valves (CI body SS disc nitrile sheet & O ring & PN16 pressure rating as specified)
200mm dia.
100mm dia.
80mm dia.
50mm dia.
Y strainer (Ductile CI body flanged ends with stainless steel strainer)
200mm dia.
Supply of one number 3.5c x 25 sqmm armound aluminium PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 25 sq. mm (28mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Excavation of the trenches for pipe laying in hard rock / concrete road/ bitumine road not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing and laying in position cement concrete of 1:2:4 (1 Cement: 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) including all cost for making concrete /bitumine road surface as required at site.
Supply & fixing of Iron support/re-inforcement bar for the cooling tower foundation & base frame fabrication as per OEM recomendation.
Dismantling of old Euipments/Support/Accessories Dismantling of existing cooling towers pipe, valve, cable etc. and dump in AAI store yard.
Providing and laying reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) in foundation of cooling tower including shuttering, centering, funishing work etc complete as required (excluding reinforcement).
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material outside airport premises as per direction of Engineer - in- charge.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I.strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X5 mm G.I. strip on surface or in recess for connections etc. as required.
Blue Star Limited
VOLTAS LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .