Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.7 LAccepted-AOC R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹34.2 L+₹2.7 L (8.69%)Rejected-Finance 1 AL SHEIKH COMPLEX 1ST FLOOR PEERBAGH CHOWK SRINAGAR PEERBAGH SRINAGAR BUDGAM JAMMU KASHMIR 190014 | BUDGAM | JAMMU AND KASHMIR | 190014 | L-2 | Rejected-Finance BEING L-2 | |
| 3 | L-3₹35.0 L+₹3.6 L (11.5%)Rejected-Finance | L-3 | Rejected-Finance BEING L-3 | |
| 4 | L-4₹36.8 L+₹5.4 L (17.1%)Rejected-Finance | L-4 | Rejected-Finance BEING L-4 | |
| 5 | L-5₹42.6 L+₹11.2 L (35.6%)Rejected-Finance | L-5 | Rejected-Finance BEING L-5 |
Tender Value
₹47.3 L
EMD Value
₹94,500
Closing Date
17 Aug 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
SPECIAL REPAIR TO BUILDING NO T 44 AT GRN A AND T 10 AT GRN B OF KHANABAL GRN UNDER GE 861 EWS
2022_MES_539495_1
GE 861EWS-36/2022-2023
Open Tender
Civil Works
Fixed-rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹94,500
Yes
27 Sept 2022
20 Jul 2022
24 Aug 2022
20 Jul 2022
17 Aug 2022
3 Aug 2022
Amount
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all arches quoins etc but excluding ashlar facing, dressed stone work & precast concrete articles etc complete all as specificed and directed.
Demolition of cement concrete (unreinforced) in ground floors & paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store complete all as specified and directed.
Demolition of cement reinforced concrete (reinforcement cut as required to facilitate demolition) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed.
Taking down shutter of any description area n.exc 1.00 sqm each complete all as specified and directed.
Taking down of shutter any description area exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and directed.
Dismantling of timber scantling under 40 Sqcm, fixed in any position in fillet rails, posts rafters purlin etc complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Demolition and breaking up PVC (SWR), CI, AC drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and removing rubbish from site complete all as specified and directed.
Demolition wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets & snap grid frame etc, complete all as specified and directed.
Precast cement concrete type C-1(using 16mm graded crushed stone aggregate) solid block masonry with hollow blocks exceeding 10cm in width and setting in mortar 1:6, complete all as specified and directed.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:3 finished even and smooth without using extra cement, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Glazed ceramic coloured tiles 450mm x 350mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Vitrified tiles 10 mm thick, light shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Chequered coloured cement concrete tiles of size 300 x 300 x 25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
80mm thick factory made machine pressed precast concrete, glossy finished coloured interlocking paver block with grey cement and pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-40 grade, complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
Hard core of broken stone or boulders of guage exc 63mm but n. exc 100mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
25mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
75mm thick PCC 1:3:6 Type C-2 (40 mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, etc., complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
RCC M-25 design mix using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate as in beams, cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate in column, pillars, piers, posts and struts complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finish surface of concrete square, rectangular or polygonal complete all as specified and directed.
MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed.
35mm thick, 2nd class softwood factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
35mm thick, 2nd class softwood factory made glazed and skeleton shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
30mm thick, 2nd class softwood factory made glazed and skeleton shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (b) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, worught, framed rebated on the solid, rounded of chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame, complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in walls with nails to timber frame, complete all as specified and directed.
20mm thick 2nd class hardwood clean sawn boards or planks, width n exc. 20cm, complete all as specified and directed.
2nd class softwood plain fillets square/rectangular or triangular in section of sectional area exc 13 Sqcm but n exc 25 Sqcm, complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area exc 3 Sqcm but n exc 6 Sqcm complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area not exc 3 Sqcm, complete all as specified and directed.
300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
100mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
100mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
75mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
140mm long, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
3mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
3mm thick figured glass pin headed type and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
Steel water tubing, 15mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Steel water tubing, 20mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Rotational moulded polythylene 1000 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20mm brass ball valve high pressure with brass rod & high density plastic ball including dismantlling of existing tank, complete all as specified and directed.
S&F in repairs vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) but including cast iron 'P' trap, jointing to flush pipe, inject connection to trap, antisyphonage etc. complete and making good to floor in cement concrete M-5 (1:5;10), type E-2 using 40mm graded crushed stone aggregate, complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including 'P' or 'S' trap, seat cover and fixing bolts, flushing cistern and flush pipe & making good to floor in cement mortar M-15 (1:2:4) type B-1 (using 20mm graded crushed stone aggregated), complete all as specified and as directed.
S&F in repair 10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets, complete all as specified and directed.
S&F in repair vitreous china, wash hand basin, white, flat back, of size 550mmx400mm, oval type including cutting for and pinning ends of brackets or erecting stand, waste coupling and waste pipe, complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed.
S&F in repair 15mm bore bib tap with wall flange, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
S & F in repair 15mm dia pillar taps, fancy type, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered 'Hot' and 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm bore stop/angle valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges, complete all as specified and directed.
110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
110mm bore dia PVC (SWR) bends, complete all as specified and directed.
110mm bore pipe PVC (SWR) vent cowl and fixed, complete all as specified and directed.
110mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed.
S&F in repairs 75mm dia outlet PVC (SWR) multi floor trap with openable grating including jointing with solvent cement, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Complete removal of existing treatment of walls & applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Preparation of new plastered surfaces of wall to receive 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of oil bound distemper over a coat of priming coat and wall care putty, complete all as specifed and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of old painted wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint to match the existing surface, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-84 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-84 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No-84 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Modular one way switch 6 Amp, 1 module, complete all as specified and directed.
Modular one way switch 16A, 1 module, complete all as specified & directed.
Modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed.
Modular socket outlet, 6A/16A-2/3 pin combined 2 module, 230 volts complete all as specified & directed.
Modular fan step regulator, 120W - 2 module, complete all as specified & directed.
Modular white cover plate with frame, 2 module, complete all as specified and directed.
Modular white cover plate with frame, 3 module, complete all as specified and directed.
Modular white cover plate with frame, 4 module, complete all as specified and directed.
Modular white cover plate with frame, 6 module, complete all as specified and directed.
Modular white cover plate with frame, 8 module, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
S & F in repair LED lamp 10 W, complete all as specified and directed.
Supply, installation, testing and commissioning of decorative ultra slim linear LED in replacement of 20 Watt , 4' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack including LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube, complete all as specified and directed.
35 Watt LED street light fitting 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down all unsv, complete all as specified and as directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB distribution board , 415 volts TPN, vertical type double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "B" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
MCCB 4 pole, 415 volts adjustable type, 63 Amps with breaking capacity 25 KA complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 13.50%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material including taking down old unsv, complete all as specified and directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor including taking down old unsv, complete all as specified and directed.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including taking down old unsv, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv, complete all as required at site or directed.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 sqmm nominal cross section 3.50 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
Supply and laying in repairs 50mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
M/S Sofi Brothers
BHAT CONSTRUCTIONS AND BUILFERS
M/S BILAL AHMAD BHAT
JANDOO AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .