| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC 182 INDRA COLONY VILL DAMODARPURA POST TODABHATA TEA BASSI BASSI JAIPUR JAIPUR RAJASTHAN 303301 | JAIPUR | RAJASTHAN | 303301 | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹9.3 L+₹11,536 (1.26%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹9.9 L+₹73,586 (8.03%)Rejected-AOC 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹10.1 L+₹90,481 (9.87%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹11.0 L+₹1.8 L (19.6%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
1 Jul 2020, 6:00 pmClosed
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-02/2020-21
2020_MES_338902_1
GE(H)-02/2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹29,000
Yes
20 Jul 2020
15 Apr 2020
3 Jul 2020
15 Apr 2020
1 Jul 2020
4 May 2020
Amount
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil all as specified.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil all as specified.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil all as specified.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface all as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete all as specified.
M&L for PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete all as specified.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified.
M&L reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in foundations including rafts, footings, foundation beams, plinth beam, bases for columns, mass concrete and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L formwork to edges of concrete flats, roofs, floors etc not exc 10cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces all as specified.
Supply only liquid water proofing compound (ISI marked).
M&L for brick work using old size fly ash bricks as specified in clasue 6 of Particular specification, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L for reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
S&F mild steel framed work using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. complete all as specified & as directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed.
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long, dia of neck exc 20mm but not exc 25mm complete all as specified & as directed.
S&F mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete, all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified & directed.
M&L for 100 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for 75 mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor top, surface finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement and mixed with liquid water proofing compound as per manufacturer's instructions complete all as specified. Note : - Supply only liquid water proofing compound shall be measured and paid for separately.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including wooden / pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, fixed on pipe complete all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 26.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 26.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 26.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per srl item No. 26.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F LED bulb of capacity 15 W, ISI marked, all as specified and directed.
S&F LED light fitting 1x18W, batten for Retro LED energy saving tube light, ultra bright LED polycarbonate Tubelight with very high efficacy ready to use pack including LED tube all as specified and directed. Make : Havells Regal batten Cat Part No REGALBATTENT5UPTO1X18WDSBSWH & LED tube rod Cat Part No PHOTONULTRA1213T8SSTL18WLED865SPC or Syska Cat Part No SSK-TST-18W or Cat No LT 8-20-865-2 of Crompton or Cat part No HLT84DPC18CW of Halonix or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F new generation LED 90/100 Watt on wall / ceiling, high bay with high luinous efficacy, IP-65 protected, front tightened glass with discrete high power including reflector complete all as specified and directed. Make : Make : Cat Part No JETAIRISFLS100WLED757ASYMLTG of Havells or Cat Part No SSK-BLS-90W of Syska or Cat part No PCGLF T1 02 100 57 of polycab or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, TPN with 200 Amps rated bus bar, 4 way, 240 Volts. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts. Make :- Indo Asian Cat Part No 810347 or equivalent of makes mentioned in list of makes here-in-after .
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S & F MCB SPN, 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S & F MCB TPN, 63 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
Supply and fixing one star rated energy saving ceiling fan 1200mm sweep as per alest IS-374-2019 having service value > 4 to < 4.5 m3/min/w and 50 watt with double ball bearing and three blades with all accessories, down rod, two nos canopy, white in colour including 2 core 0.5 sqmm copper flexible cable for connection from ceiling rose to fan complete all as specified and directed.
Supply & fixing heavy duty Air circulation fan of 450mm sweep, complete including fixing on wall / pipe complete, connecting with & including 3 core 0.5 sqmm copper flexible cable from ceiling rose to fan complete.
Supply , laying , jointing, testing and commissioning of cable of size 50 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors as per IS 7098 (Part-I), laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness afterlaying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
S&F Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor in green colour, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including PVC conduit fixed on wall/ceiling with PVC saddles, ISI marked & conduit fittings/accessories of medium grade not less than 25mm dia complete. Note :- 02 runs of 6 sqmm size, 01 run of 6 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/ washers, protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
M/s INDER CONSTRUCTION COMPANY
VERMA BROTHERS
M/S KAVITA CONSTRUCTION
LACHHMAN SINGH AND BROTHERS
m/s Rajesh Kumar
SITA RAM AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .