| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.0 LAccepted-AOC VILL KISHANPURA P O JAMNIWALA TEHSIL PAONTA SAHIB DISTRICT SIRMOUR HP | PAONTA SAHIB | SIRMOUR | HIMACHAL PRADESH | L-1 | Accepted-AOC OK | |
| 2 | L-2₹9.2 L+₹18,050 (2.00%)Rejected-Finance VILL FAGOG P O BALOH TEHSIL JHANDUTTA DISTT BILASPUR HP | L-2 | Rejected-Finance OK | |
| 3 | L-3₹9.5 L+₹45,206 (5.01%)Rejected-AOC 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L-3 | Rejected-AOC OK |
Tender Value
₹11.0 L
EMD Value
₹22,050
Closing Date
27 Jun 2023, 5:00 pmClosed
EXECUTIVE ENGINEER ELECT HIMUDA
EXECUTIVE ENGINEER ELECT HIMUDA ELECTRICAL DIVISION KASUMPTI SHIMLA 171009
CONSTRUCTION OF 6 NOS CAT-III INTERNAL ELECTRICAL INSTALLATION WORK THEREIN
2023_HIMUD_74756_1
HIMUDA PP and E W7 2020 502-11 dated 02.06.2023
Open Tender
Electrical Works
Item Rate
300 days
SANJAULI
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
₹22,050
Yes
24 Jul 2023
12 Jun 2023
28 Jun 2023
13 Jun 2023
27 Jun 2023
13 Jun 2023
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed medium class PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and approved by the Engineer-in -Charge. Group A.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required and approved by the Engineer-in -Charge.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required and approved by the Engineer-in -Charge.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required and approved by the Engineer-in -Charge.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required and approved by the Engineer-in -Charge.2x1.5 Sq. mm. 2x1.5 Sq. mm.
2x 10 Sq. mm..
Supplying and drawing LAN cable TV cable , solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required and approved by the Engineer-in -Charge. 1run of cable.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required: and approved by the Engineer-in -Charge 20 mm. dia
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required and approved by the Engineer-in -Charge TV. Socket outlet, modular.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required and approved by the Engineer-in -Charge 2 modules (78mmx78mmx50mm)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required and approved by the Engineer-in -Charge.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required and approved by the Engineer-in -Charge.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required and approved by the Engineer-in -Charge.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required and approved by the Engineer-in -Charge Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required and approved by the Engineer-in -Charge. 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required and approved by the Engineer-in -Charge. 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required and approved by the Engineer-in -Charge. Double door-6way
Double door-16 way
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal or coke and salt ) complete as required and approved by the Engineer-in -Charge.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required and approved by the Engineer-in -Charge.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required and approved by the Engineer-in -Charge. . (OD-90 mm & ID-76 mm nominal)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- Armoured cable and approved by the Engineer-in -Charge 70sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size and approved by the Engineer-in -Charge. Armoured cable 70 sq. mm (3.5 core)
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Nonreturn valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required and approved by the Engineer-in -Charge. 25 ltr cat A
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required and approved by the Engineer-in -Charge. 1200 mm
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, with lauvers and shutter making good the damages, connections, testing and commissioning etc. as required and approved by the Engineer-in -Charge. Exhaust Fan, light duty, 300 mm sweep
Providing and installation of following type of LED batten with aluminium housing, anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clamps, connections, testing etc. as required and approved by the Engineer-in -Charge. LED Batten Light 20W
Supplying and fixing of fancy wall bracket suitable for input voltage: AC 220- 240 V, 50/60Hz, complete with all accessories, lamp holder, but excluding lamp including making connections, testing etc. as required and approved by the Engineer-in -Charge. Wall light fixture Polycarbonate body, suitable for 9 W retrofit LED lamp B22 base.
Providing and installation of following type of surface/recessed mounting square/round type LED panel 6 wattLight with aluminium die cast housing in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required and approved by the Engineer-in -Charge.
Providing, and fixing of Fan Box as required and approved by Engineer- in -Charge.
Providing and fixing Instant geyser with product code GHWEOBPWH003 of Capacity 3 Ltr /3 KW havellsor equivalent make as required and approved by the Engineer-in- Charge.
Providing and fixing LED Mirror light 5 W LED 6000 K Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate product code LHEXBLP7IN1W005 cool white of Havells or equivalent make as required and approved by the Enginner-in-Charge.
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 2mm mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments including 160A FP 25KA MCCB TMD BASED WITH ADJUSTABLE O/L & S/C PROTECTION WITH SPREADER ,Bus Bar 200A,INDICATION LAMP R/Y/B, 240V AC,6A SP MCB, 10KA, C-CURVE and spacing for 6 No. Electrical meters along with the the internal connections of make Indoasian and equivalent as approved by Engineer- in- Charge.
Supplying and fixing of Led lamp 9 watt of Havells and equivalent Make as approved by Engineer- in- Charge.
Supplying and fixing of HEXA 10 W IP66 Bulk Head Product code HEXAFT10WLED857SSYMBOPC of havells and equivalent Make as required and approved by Engineer- in-Charge
Kashmir Singh
Kumar Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .