Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹1.1 Cr | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹1.2 Cr+₹6.6 L (5.90%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹1.2 Cr+₹6.6 L (5.90%) | L2 | Rejected-Finance Being other than Lowest Tenderer |
| 3 | L3₹1.4 Cr+₹31.7 L (28.6%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹1.4 Cr+₹31.7 L (28.6%) | L3 | Rejected-Finance Being other than Lowest Tenderer |
| 4 | L4₹2.2 Cr+₹1.1 Cr (99.7%)Rejected-Finance SIDDHARTH CO 24 PADMAVATI SOCIETY VALLABH NAGAR BHURAVAV GODHRA GUJARAT 389001 | PANCH MAHALS | GUJARAT | 389001 | ₹2.2 Cr+₹1.1 Cr (99.7%) | L4 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
3 Mar 2025, 6:55 pmClosed
MAJOR ANIL KUMAR S GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8170 COMPREHENSIVE REPAIR AND MAINTENANCE OF VARIOUS TYPES OF FANS FITTINGS FIXTURES AND OTHER CONNECTED WORKS OF INTERNAL ELECTRIC SUPPLY FOR BUILDING UNDER HQ MNA AND HQ WNC UNDER AGE EM I UNDER GE NW KUNJALI
2025_MES_697572_1
8170/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) KUNJALI
₹2.2 L
Yes
8 May 2025
12 Feb 2025
5 Mar 2025
16 Feb 2025
3 Mar 2025
17 Feb 2025
12 Feb 2025 - 16 Feb 2025
Amount
M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed for the following locations :- (a) Vajrabahu (b) DGNP (c) CG Complex (d) LWT (e) HQ WNC (f) NAD (g) New flotila Niwas (h) CCDT (j) CNAI Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items. (ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts on daily basis excluding sunday/holidays or as per requirement basis deemed to be included in the quoted rate.
M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed by Engr-in-Charge for the following locations :- (a) INS Angre (b) HQ MNA (c) Noorbuoy (d) Rafiya Manzil (e) PCDA office Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items. (ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts on daily basis excluding sunday or as per requirement basis deemed to be included in the quoted rate.
M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed by Engr-in-Charge for the following locations :- (a) HQ Chief Engineer office (b) HQ CWE office (c) INWTC (d) INS Kunjali (e) BV Yard Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items. (ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts on daily basis excluding sunday or as per requirement basis deemed to be included in the quoted rate.
M&L for overhauling/ servicing of ceiling fan of any size / sweep (i.e 1200/1400mm sweep) and make comprising dismantaling, cleaning internally and externally and cleaning / lubricating of bearing / bushes using fresh lubricant (Oil grease) re-assembling, checking of split pin, hook assembly & hanging at the site and testing for proper functioning complete all as specified and directed. NOTE : Necessary spares shall be measured and paid separately under relevant item here-in-after, however replacement of defective split pin shall deemed to be included in the item rate.
All as per ser item No. 4 here in before but in exhaust fan of 225/300 mm sweep complete all as specified and directed.
All as per serial item No 4 here-in-before but for exhaust fan of 380/450 mm sweep complete all as specified and directed.
Dismantaling / opening ceiling fan of 1200 mm sweep, transporting to civil workshop and taking out all burnt/damaged windings insulating materials & cleaning internally as well as externally, rewinding the fan motor with super enamelled copper wire as as per existing size /specification, replacement of complete insulating materials, varnishing drying up, cleaning & greasing of bearing / buses using new grease, reassembling and testing complete all as specified and directed. NOTE : Necessary spares such as bearing / bushes, capacitor, 3 core flexible wire, canopy etc. shall be measured and paid separately under relevant item here in after.
Supply and fixing of ceiling fan stator of 1200mm sweep complete all as specified and directed.
Supply and fixing of rotor for 1200 mm sweep ceiling fan complete all as specified and directed.
M&L for replacement of fan blade set suitable for ceiling fan of 1200 sweep complete all as specified and directed.
M&L for replacement of set of ball bearing suitable for ceiling fan 1200mm sweep size including taking down the unserviceable one complete all as specified and directed
M&L for replacement of gun metal bush suitable for ceiling fan 1200mm sweep size and make after taking down the unserviceable one complete all as specified and directed.
M&L for spray painting of ceiling fan of any make, 1200mm sweep after preparation of old painted surface with one coat of white synthetic enamelled paint including writing of MES No. with black paint complete all as specified and directed.
M&L for mild steel down rod of suitable size and dia as directed for ceiling fan of 1200 mm sweep after dismantling the existing unserviceable one complete all as specified and directed .
M&L for body cover for 1200 mm sweep ceiling fan suitable for existing complete all as specified and directed.
Dismantaling / opening up and taking down ceiling fan of 1400 mm sweep, taking out all burnt/damaged windings insulating materials & cleaning internally as well as externally, rewinding the fan motor with super enamelled copper wire as as per existing size /specification, replacement of complete insulating materials, varnishing drying up, cleaning & greasing of bearing / buses using new grease, reassembling and testing complete all as specified and directed. NOTE : Necessary spares such as bearing / bushes, capacitor, 3 core flexible wire, canopy etc. shall be measured and paid separately under relevant item here in after.
Supply and fixing of ceiling fan stator of 1400mm sweep complete all as specified and directed.
Supply and fixing of rotor for 1400 mm sweep ceiling fan complete all as specified and directed.
M&L for replacement of blade suitable for ceiling fan of 1400 sweep complete all as specified and directed.
M&L for replacement of ball bearing suitable for ceiling fan 1400mm sweep size including taking down the unserviceable one complete all as specified and directed
M&L for replacement of gun metal bush suitable for ceiling fan 1400mm sweep size and make after taking down the unserviceable one complete all as specified and directed.
M&L for spray painting of ceiling fan of any make, 1400mm sweep after preparation of old painted surface with one coat of white synthetic enamelled paint including writing of MES No. with black paint complete all as specified and directed.
M&L for mild steel down rod of suitable size and dia as directed for ceiling fan of 1400 mm sweep after dismantling the existing unserviceable one complete all as specified and directed .
M&L for body cover for 1400 mm sweep ceiling fan suitable for existing complete all as specified and directed.
All as per serial item No. 24 here-in-before but for exhaust fan of 225mm sweep complete all as specified and directed.
All as per ser item No. 24 here-in-before but for exhaust fan of 300 mm sweep complete all as specified and directed.
All as per ser item No. 24 here-in-before but for exhaust fan of 380/450 mm sweep complete all as specified and directed.
All as per ser item No. 24here-in-before but for wall mounting / pedestal fan of 400/450 mm sweep complete all as specified and directed.
M&L for spray painting of exhaust fan cabin / wall mounting and pedestal fan etc. of any make and sweep after preapration of old painted surface with one coat of grey synthetic enamel paint inlcuding writing of MES No. with black paint complete all as specified and directed.
M&L for replacement of canopy for ceiling fan of 1200/1400 mm sweep including dismantling of unserviceable one complete all as spicified and directed.
M&L for replacement of fan regulator resistance type including dismantling of unserviceable one complete all as specified and as directed
M&L for replacement of stepped type electronic fan regulator flush type on the existing laminated sheet including taking down the existing unserviceable fan regulator complete all as specified and directed.
Supply only modular fan step regulator, 120W - 2 modular all as specified and directed.
M&L for replacement of fan capacitor 2.5 MFD after taking down the unserviceable one complete all as specified and directed. MAKE : Bajaj / Universal / Usha.
All as per ser item No. 34, here in before, but capacitor 3.15 MFD complete all as specified and directed. MAKE : Bajaj / Universal / Usha or equivalent make approved by GE
S&F for replacement of ball bearing / bush for exhaust fan after taking down the unserviceable one complete all as specified and directed. MAKE : TATA/NBC/SKF or equivalent make approved by GE
M&L for dismantling old u/s pole from site and supply and erection of solar column street light pole with connected solar street light with lithium ferro phosphate battery, solar panel, solar charger built into the luminaries with pressure dia cast aluminium body with efficacy more than 175 lum/watt with capacity not less than 20W complete all as specified and directed. Make :Bajaj cat part No. BSSL 45M 20W SL or equivalent make mentioned in list of manufactures
M&L for dismantling old u/s pole from site and supply and erection of solar column vertical light pole with the column vertial lights attachment for solpole with lithium ferro phosphate battery, solar panel, solar charger built into the luminaries with pressure dia cast aluminium body with efficacy more than 175 lum/watt with capacity not less than 20W complete all as specified and directed by Engr-In-Charge. Make :Bajaj cat part No. BSSCL 45M 20W VL or equivalent make mentioned in list of manufactures
M&L 1.5 sqmm flexible cable (three core) with stranded copper conductor after taking down the unserviceable one complete all as specified and directed .
M&L for replacement of shackle sub assy with rubber reel, two set of nut , bolt , washer and split pin suitable for ceilling fan of any size and make dismantling existing unsv one complete all as specified and as directed .
S&F in repair of double door type SPN DB 12 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507612 or equivalent make from list of manufactures. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 08 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611or equivalent make from list of manufactures . Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type vertical type TPN DB 4 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed. Make: Legrand cat No 507782 or equivalent make mentioned in list of manufactures Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type vertical type TPN DB 6 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed.Make: Legrand cat No 507782 equivalent make mentioned in list of manufactures . Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
Taking down and M&L for sub-main wiring with 2 runs of 2.5 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing and caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Taking down & M&L for sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Supply and fixing in repair walll/surface mounted 20W LED tube light fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed .
S & F ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 10W LED complete all as specified and as directed.
S & F LINNET LED Mirror Light 14/15 Watts, 1' (FEET) made of extruded engineering plastics suitable for surface mounting on a ceiling or wall complete all as specified and as directed. Make : Crompton Cat Part No LCL-14-CDL or equivalent make mentioned in list of manufactures
Supply & fixing City 1 decorative wall light fixture made up of polycarbonate, suitable for 15 W retrofit LED lamp (Spiral B-22 base) complete all as specified and as directed.
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408595 or equivalent make mentioned in list of manufactures including making connection complete all as specified and as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408596 or equivalent make from list of manufactures including making connection complete all as specified and as directed.
S & F MCCB, 415 volts, four pole of cap 100 Amps, 25 KA, DPX3 with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as specified and as directed. Make - Legrand cat No 420055 or equivalent make from list of manufactures
S & F MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, DPX3 with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as specified and as directed. . Make - Legrand cat No 42006 or equivalent make mentioned in list of manufactures
S & F MCCB, 415 volts, four pole of cap 200 Amps, 25 KA, DPX3 with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as specified and as directed. . Make - Legrand cat No 4202 18 or equivalent make mentioned in list of manufactures
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and fixing in repair new generation recessed mounted ultra slim panel LED 2X2 Luminaire 36 watt and CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting to modern offices. Suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make : CG/wipro/C&S Cat No: LTCRSLM36WATT2x2 or equivalent make mentioned in list of manufactures
Taking down & M&L for sub-main wiring with 2 runs of 6.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces as directed.
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVC Modular box with cover plate fixed on wall for fixing the switches, switch sockets,sockets, regulators etc complete all as specified for One light point controlled by one 5A switch:- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Yellow/Blue ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit. (c) Make of wire :- Havells/ Finolex/ Plaza/Gloster/Polycab. (d) Make of PVC casing capping :- Precision/ pesto plast / National/Plaza
All as per item No. 61 but for One Fan point controlled by one 5A switch complete all as specified and as directed.
All as per item No. 61 but for One Exhaust Fan point controlled by one 5A switch complete all as specified and as directed.
All as per item No. 61 but for One 5A flush type switch socket point on same board board complete all as specified and as directed.
All as per item No. 61 but for One 5A flush type switch socket point on independent board complete all as specified and as directed.
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately.
S & F in repairs modular switch 1 way 16A, 1 module all as specified and directed.
S & F in repairs modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed.
S & F in repairs modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed.
S & F in repairs modular switch 1 way 6A, 1 module all as specified and directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as directed.
Supply and fixing modular white cover plate with frame 4 module complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and as directed.
Supply only modular white cover plate with frame 8 module complete all as specified and as directed.
Supply and fixing modular PVC flush box 4 module complete all as specified and as directed.
Supply and fixing modular PVC flush box 6 module v
Supply only modular PVC flush box 8 module complete all as specified and as directed.
S&F exhaust fan air fan of size 250 mm sweep, non matallic complete all as specified and as specified and as directed. Make : Havells code No. Ventil Air - DX or equivalent make from list of manufactures
S&F exhaust fan air fan of size 300 mm sweep, non matallic complete all as specified and as specified and as directed. Make : Havells code No. Ventil Air - DX or equivalent make from list of manufactures
ASHOK ENTERPRISES (BID ID -3247829)
SHRI SAI ENTERPRISES (BID ID -3247169)
siddharth and company (BID ID -3248063)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .