Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.8 LAccepted-AOC 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹62.9 L+₹8.1 L (14.8%)Rejected-Finance SCHINDLER HOUSE MAIN STREET HIRANANDANI GARDENS POWAI MUMBAI 400076 MAHARASHTRA INDIA | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | L2 | Rejected-Finance Quoted Highest Rate |
Tender Value
₹45.5 L
EMD Value
₹90,900
Closing Date
19 Mar 2025, 1:00 pmClosed
SE,KHEC,PWD
Kolkata Health Electrical Circle, P.W.Dte KIT Annex Building, 5th Floor KOLKATA
Construction of New Building for Patient Care Services in the campus of Medical College and Hospital, Kolkata - Part D. SITC of Lift- 2 Nos. MRL Lift ,One Bed-cum-passenger and one passenger lift.
2025_WBPWD_817185_1
WBPWD/SEKHEC/KNHED/eNIT22/ 24-25/2ndCall
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
Medical College and Hospital
Please refer Tender documents.
7 documents required · 7 mandatory
₹90,900
Office of the SE,KHEC,PWD
26 Jun 2025
19 Feb 2025
21 Mar 2025
19 Feb 2025
19 Mar 2025
27 Feb 2025
25 Feb 2025
Amount
SITC of automatic lift (as per manufacturer design as per detailed spectfication below conforming to IS) and putting into operation after final testing in the existing shaft complete with all accessories and reparing the damaged wall /floor if any etc to complete as required.
Make:- OTIS/ KONE/ Schindler
Type : Passenger Lift
Load : 15 Passenger / 1020 Kg.
Control: Microprocessor based with AC Variable Voltage & Variable frequency (VVVF)
Machine: Energy Efficient Machine ; Gearless, without Machine Room.
Speed : 1.0 Mtr. /Sec.
Floor Served : G + 6
Landing : 7 (Seven) lands ; All on same sides
Total Rise : 25.2 Mtr. (approx) (Bidder should follow the CGA drawing/ Visit the site, as applicable)
Operation : Microprocessor based simplex full collective with or without attenedent.
Signals : Digital Car postion indicator, car travels direction indicator in car and at all landing with call registration indicator. COP & LOP must have stainless steel face plate silver brushed with surface mounted button with braille. Button : All buttons on car & landing shall be luminous & encoded with braille on/off switch for Lift, fan, light, toggle switch or key switch for automatic/attendent mode of operation. Display type : Monochrome/ Colour LCD / Segmented LCD/ Scroll. Operation Push Buttom for lift maintenance & service should be on top of the car.
Travelling Accuracy: ± 5mm (Micro Levelling Arrangement)
Car Inside : 1600 mm (W) X 1500 mm (D) × 2200 mm (H)
Car Entrance : Clear Opening 1000mm (W) X 2000mm (H) protected with car door.
Car Encloser: Stainless Steel Sheet (20SWG) with hair line finish with hand rail.
Car Ceiling & Lighting : Stainless Steel with hair line finish with LED Lighting & Fan.
Car Ventilation : Axial fan with anodised aluminium / SS grill.
Car Flooring : Decorative Granite Flooring (As per direction of EIC and according to departmental order.)
Car Door : Stainless Steel Centre Opening (COPD) / Telescopic Opening (TSPD) automatic door provided with V3F controlled door drive system.
Landing Door: Stainless Steel Centre Opening (COPD) / Telescopic Opening (TSPD) automatic door provided with V3F controlled door drive system with fire rating of 120 min.
Door Opening: Automatic Power operated door with full length photocell assembly curtain sensor.
PROTECTIVE DEVICES & OTHER ACCESSORIES :-
ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of power failure / single phasing/others.
Overload Protection:Fully loaded with overload protection. On overloading condition the lift car will not start with door remaining open and give audio & display indication.
Emergency Lighting In Car: Battery operated emergency lighting in the lift car.
Intercom System: Battery operated Intercom System in Lift Car, Machine Room & Control Room.
Emergency Alarm: Battery Operated alarm bell system in Lift Car & Control Room.
Fireman switch : Fireman switch placed at ground floor.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the lift.
Car Parking at top floor at idle condition.
Main Wire Rope/ Belt : As per manufacturer's standard conforming to IS.
Auto fan Cut-Off
DIMENSION OF SHAFT & POWER SUPPLY :-
Available Shaft Dimension: 2550 mm (W) X 2100 mm (D)
Pit Depth: 1600mm ( Bidder should visit the site)
Overhead: 4600mm ( Bidder should visit the site)
Electric power supply: AC 415V, 3Phase, 50Hz terminated in machine room as per IS.
External Monitoring system through MOD BUS RS485
MINOR MASONARY WORK :-
If the gap between the door frame and wall structure is up to ± 50 mm then the cost should include the required minor masonary works needed to plug the gap , if necessary, as per direction of EIC.
SITC of automatic lift (as per manufacturer design as per detailed spectfication below conforming to IS) and putting into operation after final testing in the existing shaft complete with all accessories and reparing the damaged wall /floor if any etc to complete as required.
Make:- OTIS/ KONE/ Schindler
Type : Bed cum Passenger Lift
Load : 20 bed cum Passenger / 1360 Kg.
Control: Microprocessor based with AC Variable Voltage & Variable frequency (VVVF)
Machine: Energy Efficient Machine ; Gearless, without Machine Room.
Speed : 1.0 Mtr. /Sec.
Floor Served : G + 6
Landing : 7 (Seven) lands ; All on same sides
Total Rise : 25.2 Mtr. (approx) (Bidder should follow the CGA drawing/ Visit the site, as applicable)
Operation : Microprocessor based simplex full collective with or without attenedent.
Signals : Digital Car postion indicator, car travels direction indicator in car and at all landing with call registration indicator. COP & LOP must have stainless steel face plate silver brushed with surface mounted button with braille. Button : All buttons on car & landing shall be luminous & encoded with braille on/off switch for Lift, fan, light, toggle switch or key switch for automatic/attendent mode of operation. Display type : Monochrome/ Colour LCD / Segmented LCD/ Scroll. Operation Push Buttom for lift maintenance & service should be on top of the car.
Travelling Accuracy: ± 5mm (Micro Levelling Arrangement)
Car Inside : 1300 mm (W) X 2400 mm (D) × 2200 mm (H)
Car Entrance : Clear Opening 1200mm (W) X 2000mm (H) protected with car door.
Car Encloser: Stainless Steel Sheet (20SWG) with hair line finish with hand rail.
Car Ceiling & Lighting : Stainless Steel with hair line finish with LED Lighting & Fan.
Car Ventilation : Axial fan with anodised aluminium / SS grill.
Car Flooring : Decorative Granite Flooring (As per direction of EIC and according to departmental order.)
Car Door : Stainless Steel Centre Opening (COPD) / Telescopic Opening (TSPD) automatic door provided with V3F controlled door drive system.
Landing Door: Stainless Steel Centre Opening (COPD) / Telescopic Opening (TSPD) automatic door provided with V3F controlled door drive system with fire rating of 120 min.
Door Opening: Automatic Power operated door with full length photocell assembly curtain sensor.
PROTECTIVE DEVICES & OTHER ACCESSORIES :-
ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of power failure / single phasing/others.
Overload Protection:Fully loaded with overload protection. On overloading condition the lift car will not start with door remaining open and give audio & display indication.
Emergency Lighting In Car: Battery operated emergency lighting in the lift car.
Intercom System: Battery operated Intercom System in Lift Car, Machine Room & Control Room.
Emergency Alarm: Battery Operated alarm bell system in Lift Car & Control Room.
Fireman switch : Fireman switch placed at ground floor.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the lift.
Car Parking at top floor at idle condition.
Main Wire Rope/ Belt : As per manufacturer's standard conforming to IS.
Auto fan Cut-Off
DIMENSION OF SHAFT & POWER SUPPLY :-
Available Shaft Dimension: 2350 mm (W) X 2950 mm (D)
Pit Depth: 1600mm ( Bidder should visit the site)
Overhead: 4600mm ( Bidder should visit the site)
Electric power supply: AC 415V, 3Phase, 50Hz terminated in machine room as per IS.
External Monitoring system through MOD BUS RS485
MINOR MASONARY WORK :-
If the gap between the door frame and wall structure is up to ± 50 mm then the cost should include the required minor masonary works needed to plug the gap, if necessary, as per direction of EIC.
Terms and Condition:
i) The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
ii) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
iii) If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 3 (Three) Years
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
SCHINDLER INDIA PRIVATE LIMITED (BID ID -6206892)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .