Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 CrAccepted-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹10.0 Cr Quoted ₹10.1 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹10.3 Cr+₹24.3 L (2.41%)Rejected-AOC 279 A 22 SONIPAT ROAD ROHTAK 124001 HARYANA | ROHTAK | ROHTAK | HARYANA | 124001 | ₹10.3 Cr+₹24.3 L (2.41%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹10.9 Cr+₹80.5 L (7.99%)Rejected-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | ₹10.9 Cr+₹80.5 L (7.99%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹11.1 Cr+₹1.0 Cr (10.0%)Rejected-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹11.1 Cr+₹1.0 Cr (10.0%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹11.6 Cr+₹1.6 Cr (15.4%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹11.6 Cr+₹1.6 Cr (15.4%) | L5 | Rejected-AOC Rejected |
Tender Value
₹10.4 Cr
EMD Value
₹20.8 L
Closing Date
26 Jul 2024, 4:00 pmClosed
TARUN Garg
Rohtak PHED No. 2
PROVIDING STORM WATER SEWER and DISPOSAL
2024_HRY_387522_1
2024F3B58C67 5135 41B9 8336 0505D57AF882577PUH
Open Tender
Civil Works
Works
270 days
Meham
2 documents required · 2 mandatory
₹20,000
₹20.8 L
Yes
12 Nov 2024
5 Jul 2024
26 Jul 2024
5 Jul 2024
26 Jul 2024
5 Jul 2024
Amount
Supply and installation of mechanical bar screens suitable for for 35.00 MLD flow complete in all respect
STEEL BRIDGE: Design and construction of Structural steel bridge in built up sections, trusses and framed work, cutting, hoisting, fixing in position and applying a priming and final coat of approved steel primer / paint including design and construction of bridge foundation , thrust block and all other components complete in all respect for crossing the canal for laying the 900 mm i/d DI pipe line.
NON CLOG SEWAGE PUMP: Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentiond as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 6800 LPM x 25 m
NON CLOG SEWAGE PUMP: Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentiond as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 9200 LPM x 30 m
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd (95 Sqmm size)
Providing and fixing CI Gear Operated Sluice Gate 500 X 500 mm clear opening with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter
Providing and fixing CI Gear Operated Sluice Gate 750 X 750 mm clear opening with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter.
NS Item - HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG) a). VCB, 11KV, 630Amp, 50KA. b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays. e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above. f). Master trip relay -2 no’s. g). Indicator type Annunciator panel with buzzer. h). Digital Volt Meter- 0-11 KV. i). Digital Amp Meter- 0-100 Amp. j). RYB/ Trip/Closing/Spring charged indicator lamp. k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay. l) TNC Switch for Operation. m)Multifunction Meter EM6400NG. n)TCS Relay for Safety.
LT PANEL FOR IPS-2 Supply Indoor Type 0.415KV ACB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 0.415kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (3 IC plus 10 OG) 1). ACB, 0.415KV, 800Amp, 50KA. – 03 Nos 2) MCCB, 415V,250A,50KA- 10 Nos ( 1 nos outgoing for APFC Panel) 3). Control panel- Cubicle type control panel suitable for floor mounting made out of 2 mm CR sheet duly powder coated and with following relays. 4) THERMAL OVER LOAD RELAY 5) AUXILARY CONTACTOR 185a(2 NO plus 2 NC) COIL -220V – 08 6) AUXILARY CONTACTOR 185A (2 NO plus 2 NC) COIL -220V - 08 7) AUXILARY CONTACTOR 140A (2 NO plus 2 NC) COIL -220V – 08 8) TIMER 9) ELCB(96 × 96 mm) 10) AIR COOLED AUTO TRANSFORMER STARTER - 08 a)Frequency of Open. : 6 starts/hour (evenly spaced) or as per specification b) Starting time : Suitable for 12sec starting or as per specs c) Taps : 50% / 65% / 80% or as per standard d) Thermal cut-off : in-built 11)RYB Indication Light as per outgoing 12)ON/OFF/Trip Indication Light as per outgoing 13)Spring Charge Healthy Indication as per outgoing 14)Trip Circuit Healthy Indication as per outgoing 15)Push Button Test Accept and Reset as per outgoing 16)Breaker Control Switch as per outgoing 17)L/R Switch as per outgoing 18)Emergency Push Button as per outgoing 19)10-Annunciator as per outgoing 20)Pin Plug 21)Toggle Switch 22)Hooter 23)Door Switch as per outgoing 24)Space Heater with Thermostat 25)Control MCB as per outgoing 26)LED as per outgoing
LT ALUMINUM POWER CABLE: Power cable A2XFY MC-3, Stranded compacted aluminum conductor, XLPE insulated, PVC inner sheathed, Galvanised Steel Flat strip armoured and PVC sheathed confirming to IS 7098-1,IS-3961, IS 8130-1984, IS-3975, 1999, IS-4759, IS-5831, IS-10418, IS-10810 is suitable for AC single phase or three phase (earthed or unearthed) systems with rated voltage up to and including 1100 V. This cable is also suitable for DC systems with rated voltage up to and including 1500 V to earth. (240 sqmm X 3.5 core)
LT PANEL DESCRIPTION (IPS -1) Supply Indoor Type 0.415KV ACB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 0.415kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (3 IC plus 5 OG) 1). ACB, 0.415KV, 800Amp, 50KA. – 03 Nos 2) MCCB, 415V,160A,50KA- 5 Nos ( 1 nos outgoing for APFC Panel) 3). Control panel- Cubicle type control panel suitable for floor mounting made out of 2 mm CR sheet duly powder coated and with following relays. 4) THERMAL OVER LOAD RELAY 5) AUXILARY CONTACTOR 140A(2 NO plus 2 NC) COIL -220V – 03 6) AUXILARY CONTACTOR 140A (2 NO plus 2 NC) COIL -220V - 03 7) AUXILARY CONTACTOR 95A (2 NO plus 2 NC) COIL -220V – 03 8) TIMER 9) ELCB(96 × 96 mm) 10) AIR COOLED AUTO TRANSFORMER STARTER - 03 a)Frequency of Open. : 6 starts/hour (evenly spaced) or as per specification b) Starting time : Suitable for 12sec starting or as per specs c) Taps : 50% / 65% / 80% or as per standard d) Thermal cut-off : in-built 11)RYB Indication Light as per outgoing 12)ON/OFF/Trip Indication Light as per outgoing 13)Spring Charge Healthy Indication as per outgoing 14)Trip Circuit Healthy Indication as per outgoing 15)Push Button Test Accept and Reset as per outgoing 16)Breaker Control Switch as per outgoing 17)L/R Switch as per outgoing 18)Emergency Push Button as per outgoing 19)10-Annunciator as per outgoing 20)Pin Plug 21)Toggle Switch 22)Hooter 23)Door Switch as per outgoing 24)Space Heater with Thermostat 25)Control MCB as per outgoing 26)LED as per outgoing
LT COPPER CABLE FOR LT PANEL TO PUMP(IPS-1) 50sqmm * 3C * 1 Run, 1100 V Grade Multi Strand flexible annealed copper conductor, PVC Insulated and sheathed Multi - core flexible cables. Plain annealed high conductivity flexible copper conductor as per Class 5 of IS 8130/2013, latest, PVC TYPE D as per IS 5831/1984, Latest, Extruded PVC Type ST3 as per IS 5831/1984, Latest, IS 8130/2013, IS 5831/1984, IS 694/2010, etc. with latest up to date updates, As per IEC 60332-1-2.
LT COPPER CABLE FOR LT PANEL TO PUMP(IPS-2) 50 sqmm * 3C * 2 Run, 1100 V Grade Multi Strand flexible annealed copper conductor, PVC Insulated and sheathed Multi - core flexible cables. Plain annealed high conductivity flexible copper conductor as per Class 5 of IS 8130/2013, latest, PVC TYPE D as per IS 5831/1984, Latest, Extruded PVC Type ST3 as per IS 5831/1984, Latest, IS 8130/2013, IS 5831/1984, IS 694/2010, etc. with latest up to date updates, As per IEC 60332-1-2.
-Providing and installation of HT ALUMINUM POWER CABLE 6.35KV/11KV Voltage grade, 3-core Stranded, compact circular shaped Aluminum Conductor of H4 grade, Water Tree free XLPE Insulated, PVC sheathed, GI round wirearmoured, Longitudinal and radial watertight power cables, confirming to IS: 7098(Part-II), IEC-60502-2 1998, IS5819, IS-3961, IS-8130, IS-3975, IS-4759, IS-5831 and as per the technical specifications herewith attach IS code..( 1x185 sqmm ( HT meter to HT panel, HT panel To transformer) IPS-2
-LT ALUMINUM POWER CABLE: Power cable A2XFY MC-3, Stranded compacted aluminum conductor, XLPE insulated, PVC inner sheathed, Galvanised Steel Flat strip armoured and PVC sheathed confirming to IS 7098-1,IS3961, IS 8130-1984, IS-3975, 1999, IS-4759, IS-5831, IS10418, IS-10810 is suitable for AC single phase or three phase (earthed or unearthed) systems with rated voltage up to and including 1100 V. This cable is also suitable for DC systems with rated voltage up to and including 1500 V to earth. (2x 240 sqmm X 3.5 core) (Transformer to LT Panel) IPS-2
AUTOMATIC POWER FACTOR CONTROL PANEL (APFC) – 110 KVAR
POWER FACTOR CONTROL PANEL (APFC) – 410 KVAR
Providing and installation of HT ALUMINUM POWER CABLE 6.35KV/11KV Voltage grade, 3-core Stranded, compact circular shaped Aluminum Conductor of H4 grade, Water Tree free XLPE Insulated, PVC sheathed, GI round wirearmoured, Longitudinal and radial watertight power cables, confirming to IS: 7098(Part-II), IEC-60502-2 1998, IS-5819, IS-3961, IS-8130, IS-3975, IS-4759, IS-5831 and as per the technical specifications herewith attach IS code..( HT 2x95 sqm HT Panel to transformer)( HT metere to HT Panel, HT Panel to transformer ) IPS-1
Operation and Maintenance for complete scope of work covered under this contract as per OandM schedule for a period of 5 year after successful completion of 12 month`s defect liability period and 3 Months trial run complete in all respect as per approved NIT. The amount will be charged to the A/Mtc. estimate. Defect liability period (Operation only)
Operation and maintenance during 1st year
Operation and Maintenance during 2nd year.
Operation and Maintenance during 3rd year.
Operation and Maintenance during 4th year.
Operation and Maintenance during 5th year.
Bidder Name
Amount
Kulbir Singh Contractor (GSTN-06ATZPS6352H1ZW) BID ID -1120537
Rajesh Kadiyan Contractor(GSTN-NA)--1127735
kapil engineering company(GSTN-NA)--1127647
Himmat Singh Contractor(GSTN-NA)--1127783
Rathee Construction Company(GSTN-NA)--1127749
MAHA LAXMI CONSTRUCTION COMPANY(GSTN-NA)--1127698
M/S SHREE BALAJI BUILDERS(GSTN-NA)--1127718
kapil engineering company
Himmat Singh Contractor
Kulbir Singh Contractor
M/S SHREE BALAJI BUILDERS
MAHA LAXMI CONSTRUCTION COMPANY
Rathee Construction Company
kapil engineering company
M/S SHREE BALAJI BUILDERS
MAHA LAXMI CONSTRUCTION COMPANY
Kulbir Singh Contractor
Rajesh Kadiyan Contractor
Rathee Construction Company
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_463666.xls
BOQ Document • 0.32 MB
147655980.pdf
Tender Document • 0.96 MB
1D4BN2Z88783.pdf
Tender Document • 14.20 MB
OT0088783.pdf
Tender Document • 7.59 MB
147655985.html
Tender Document • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .