Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.8 L+₹2.2 L (6.40%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹36.5 L+₹2.8 L (8.32%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.2 L+₹4.5 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹45.0 L+₹11.4 L (33.8%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | LAKSHMI ASSOCIATES L3 | S.R.Enterprises L2 | M/S TRADE LINKERS L1 | SHREE BHAGWATI ENTERPRISES L4 | DIVYA ASSOCIATES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed.
Note:- Punned thickness of sand shall be measured and paid. | 213 | CUM | 111 ₹23,643 Lowest | 150 ₹31,950 | 350 ₹74,550 | 125 ₹26,625 | 400 ₹85,200 |
| 2.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. | 582 | CUM | 101 ₹58,782 | 100 ₹58,200 Lowest | 100 ₹58,200 Lowest | 108 ₹62,856 | 100 ₹58,200 Lowest |
| 3.00 | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.0 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan in soft/loose soil etc complete all as specified and directed | 0.7 | CUM | 300 ₹210 | 200 ₹140 | 300 ₹210 | 116 ₹81.2 Lowest | 300 ₹210 |
| 4.00 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed | 300 | CUM | 21 ₹6,300 Lowest | 30 ₹9,000 | 50 ₹15,000 | 54 ₹16,200 | 30 ₹9,000 |
| 5.00 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. | 282 | CUM | 21 ₹5,922 Lowest | 30 ₹8,460 | 40 ₹11,280 | 54 ₹15,228 | 40 ₹11,280 |
| 6.00 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | 3 | CUM | 3,000 ₹9,000 | 2,000 ₹6,000 Lowest | 4,000 ₹12,000 | 2,850 ₹8,550 | 2,500 ₹7,500 |
| 7.00 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges or pedestal / coping of pole including necessary form work complete all as specified and directed. | 6 | CUM | 3,333 ₹19,998 | 2,100 ₹12,600 Lowest | 3,000 ₹18,000 | 3,400 ₹20,400 | 4,000 ₹24,000 |
| 8.00 | M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed. | 15 | PER 1000 NOS | 3,900 ₹58,500 | 3,500 ₹52,500 | 2,000 ₹30,000 Lowest | 3,100 ₹46,500 | 5,000 ₹75,000 |
| 9.00 | M&L for drilling hole under road / any type of floor for laying of pipe upto 150mm dia complete all as specified and directed. | 50 | RM | 300 ₹15,000 | 100 ₹5,000 Lowest | 200 ₹10,000 | 100 ₹5,000 Lowest | 300 ₹15,000 |
| 10.00 | Supply and fix galvanised tube light grade with all fitting of size 50 mm bore for passing through cable under the floor, along the wall or along the pole /walls and ceilings or laid in floors complete all as specified and directed. | 30 | RM | 300 ₹9,000 | 170 ₹5,100 Lowest | 300 ₹9,000 | 210 ₹6,300 | 380 ₹11,400 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
18 Oct 2025, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINTENANCE OF STREET LIGHTS, LT OH/UG CIRCUIT, SWITCH GEAR, PANEL, BOARDS, MCCBS AND OTHER CONNECTED ACCESSORIES AT ZONE-III AREA UNDER GE (S) JAIPUR AT MIL STN JAIPUR
2025_MES_731896_1
GE(S)/J-38P/2025-26 8422/E8
Open Tender
Civil Works
Item Rate
270 days
GE (S) Jaipur
Class D and category b(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹94,000
Yes
15 Dec 2025
20 Sept 2025
25 Oct 2025
20 Sept 2025
18 Oct 2025
4 Oct 2025
Amount
M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.0 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan in soft/loose soil etc complete all as specified and directed
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges or pedestal / coping of pole including necessary form work complete all as specified and directed.
M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.
M&L for drilling hole under road / any type of floor for laying of pipe upto 150mm dia complete all as specified and directed.
Supply and fix galvanised tube light grade with all fitting of size 50 mm bore for passing through cable under the floor, along the wall or along the pole /walls and ceilings or laid in floors complete all as specified and directed.
Supply and fix galvanised tube light grade with all fitting of size 80 mm bore for passing through cable under the floor, along the wall or along the pole /walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair galvanised tube of 40 mm bore, light grade with all fitting complete all as specified and directed.
M&L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
M&L shackle type, porcelain, vitreous, brown, white or green insulator 1100 volts grade of maximum 90 mm dia and 75 mm height including galvanised MS strap of 31 mm x 3 mm size, 12 mm dia insulator bolts, washers and nuts, complete, conforming to IS complete all as specified and directed.
S&F in repair MCCB 4 pole, 160 Amps, 36 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
S&F in repair MCCB 4 pole, 200 Amps, 36 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
S&F in repair MCCB 4 pole, 250 Amps, 36 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
S&F in repair MCCB 4 pole, 400 Amps, 36 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
S&F in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Note : The quoted rate include the cost of assembling of the complete fitting and its testing before and after mounting or erection etc. for proper functioning.
Supply and fixing in repair LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Note : The quoted rate include the cost of assembling of the complete fitting and its testing before and after mounting or erection etc. for proper functioning.
Dismantling concrete poles including PCC foundation / struts, any size complete all as specified and directed.
S&F in repair MCCB 4 pole, 63 Amps, 16 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
M&L for disconnecting and taking down unserviceable street light / flood light fittings and accessories of any size / type / make from high mast pole / electric pole / building, safely and re-fixing after minor repair like LED driver, cleaning, tightening of loose component etc and servicing in serviceable condition including provision of cable for connection complete all as specified and directed. Note : Spare parts like LED drivers etc. are measure and paid seperately under respective items.
S&F in repair heavy duty PVC insulated copper conductor of size 2.5 Sqmm 03 core, ISI marked, 1100 Volts grade drawn through steel pole from junction box to street light fitting complete all as specified and directed.
M&L for LED driver with surge protection as per existing make or compitable for existing 45 to 60 watt LED light complete all as specified and directed.
M&L for LED driver with surge protection as per existing make or compitable for existing 60 to 80 watt LED light complete all as specified and directed.
M&L for LED driver with surge protection as per existing make or compitable for existing 80 to 100 watt LED light complete all as specified and directed.
M&L for LED driver with surge protection as per existing make or compitable for existing 100 to 150 watt LED light complete all as specified and directed.
M&L for disconnecting and taking down unserviceable timer switch assembly and accessories of any size / type / make from pole / electric panel / building, safely and re-fixing after minor repair like photo sensor, connector etc. cleaning, tightening of loose component etc and servicing in serviceable condition complete all as specified and directed. Note : Spare parts like photo sensor / connector etc. are measure and paid seperately under respective items.
M&L for connector / contactor 40 Amp 3 Pole as per existing make for street light timer complete all as specified and directed.
M&L for photo sensor for light sensing as per existing make for street light timer complete all as specified and directed.
M&L for cutting the existing cable from loop and making end terminal with aluminium lugs and cable glands (set of two) for LT UG cable of size 06 to 16 sqmm 2 core complete all as specified and directed.
M&L for cutting the existing cable from loop and making end terminal with aluminium lugs and cable glands (set of four) for LT UG cable of size 10 to 25 sqmm 4 core complete all as specified and directed.
M&L for preparation of old painted surface of street tubular poles of 09 metre height including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint to a height from 1.5 m above ground level to top of pole and making alternate strips / layers (30 cm wide) with synthetic enamel paint upto the 1.5 meter height from ground level of colour as decided by Engineer-in-Charge and including writing the pole number in white letters on black background and cleaning / cutting the grass / bushes at a radius of 02 meter surrounding the pole complete all as specified and directed.
M&L for trimming of tree branches in vicinity of electric poles and removing exc. 50m from pole and depositing where directed by Engg-in-Charge. Note : Measurement and payment shall be made by measuring span between two adjacent poles as One Job.
M&L in repair for Nature switch for automatic ON/OFF of street light by sensing natural light of 3 phase 12KW load, for switching ON less than 30 Lux, for switching OFF more than 10 Lux, auto high voltage sense and trip, auto low voltage sense and trip, 50-60Hz, IP-66 protection class 2, MCB 32-40 Amp with copper wiring by minimum of 10 Sqmm complete all as specified and directed.
M&L in repair for Nature switch for automatic ON/OFF of street light by sensing natural light of 3 phase 08KW load, for switching ON less than 30 Lux, for switching OFF more than 10 Lux, auto high voltage sense and trip, auto low voltage sense and trip, 50-60Hz, IP-66 protection class 2, MCB 32-40 Amp with copper wiring by minimum of 10 Sqmm complete all as specified and directed.
M&L for cable jointing kit for 1100V grade cable for heat shrink type straight joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10 sqmm to 35 sqmm complete all as specified and directed. Note : The quoted rate include the cost of necessary earth work if required.
M&L for cable jointing kit for 1100V grade cable for heat shrink type straight joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm to 70 sqmm complete all as specified and directed. Note : The quoted rate include the cost of necessary earth work if required.
M&L for cable jointing kit for 1100V grade cable for heat shrink type straight joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95 sqmm to 150 sqmm complete all as specified and directed. Note : The quoted rate include the cost of necessary earth work if required.
M&L for cable jointing kit for 1100V grade cable for heat shrink type straight joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed. Note : The quoted rate include the cost of necessary earth work if required.
M&L for stringing only existing ACSR (aluminium conductor steel reinforced) of any size/span on existing poles, insulators using proper tensioners and binding with aluminium binding / Clamps complete all as specified and directed. Note : (i) Each length of single conductor measured separately. (i) Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
S&F Bus bar electrolytic grade aluminium of 25×6 mm, mounted on insulators including drilling holes, disconnection & reconnection of cables from existing panel complete all as specified and directed.
S&F Bus bar electrolytic grade copper of 25×4 mm, mounted on insulators including drilling holes, disconnection & reconnection of cables from existing panel complete all as specified and directed.
S&F in repair LED indicating lamp (set of three lamps, RYB), 240 volts AC including necessary wiring complete all as specified and directed.
S&F in repair Red/Yellow/Green/Blue luminous push button complete all as specified and directed.
S&F on-load change over switch, 4 pole, 415 volt, 100 Amp suitable for existing panel including taking down the unserviceable change over switch, disconnecting and reconnecting all electrical connections, modification / fabrication if any required complete all as specified and directed.
S&F on-load change over switch, 4 pole, 415 volt, 200 Amp suitable for existing panel including taking down the unserviceable change over switch, disconnecting and reconnecting all electrical connections, modification / fabrication if any required complete all as specified and directed.
S&F on-load change over switch, 4 pole, 415 volt, 400 Amp suitable for existing panel including taking down the unserviceable change over switch, disconnecting and reconnecting all electrical connections, modification / fabrication if any required complete all as specified and directed.
M&L for cutting / removing damaged hinge (set of two) of any size and welding / fabricating new hinges with best quality in the existing panel including making good of existing surface complete all as specified and directed.
M&L for painting of LT feeder panel with two coats of synthetic enamel paint over a coat of primer and cleaning dust outside / Inside before applying paint. Note : Second coat should be applied after a gap of 24 hours. The colour of paint will be decided by Engineer-in-Charge.
Surface dressing / cleaning of vegetation at vaious locaions near by LT panels, 2 pole stucture, 4 pole structure and substation including trimming of tree branches, bushes, creepers etc. complete all as specified and directed. Note : The frequency of surface dressing shall not be less than 2 months.
M&L for preparation of old surfaces of earth pit / foundation of LT panel / Transformer, over 10cm in width or girth and apply two coat of cement base paint complete all as specified and directed. Note : The colour of paint shall be decided by Engineer-in-Charage.
M&L in repair for broken earth pit and earth pit chamber of LT panels / Transformers with proper brick masonry work & plaster in CM 1:4 including two coat of cement base paint as per site requirement complete all as specified and directed. Note : The colour of paint shall be decided by Engineer-in-Charage.
M&L for pre cast concrete earth pit cover of LT panels / Transformers of suitable size as per site requirement complete all as specified and directed.
M&L for maintenance of earthing resistance of earth pit below 03 Ohm of LT panels / Transformers by pouring 25Kg coal powder & salt together as per site requirement complete all as specified and directed.
Taking down old existing Panel and Supply, installing, commissioning and testing factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type IP 65, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber. The panel shall be dust and vermin proof, made of 3.15mm thick CRCA MS sheet, 75mm x 40 mm medium grade MS Channel frame work, duly powder coated finish having front and rear openable hinged double door shutters with aprons and cable allay for cable entry, locking arrangement and PCC work in foundation including the following provisions :- (a) MCCB 250 Amps, 4 pole, 25 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection 50 Hz, 415 volts grade - 01 Nos. (b) On-load change over switch 250 Amp, 4 pole, 415 volt - 01 No. (c) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp, 4 pole, not less than 30 cm long mounted on insulators for incoming supply- 01 No.
Taking down old panel and supply, installation, commissioning and testing of LT feeder Panel, 415 Volts, 50 Hz , 3-phase, CPRI approved, factory assembled, outdoor type, weather and vermin proof (Protection Class IP-65) 3.15 mm (for external) and 2 mm (for internal) thick CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel grey paint (first quality) over a coat of red oxide primer complete mounted on angle iron leg of size 40mm x 40mm x 5 mm and 45 cm high above GL and 15 cm embedded in ground with and including PCC work in foundation comprising of the following :- (a) Copper Bus bar: - Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, (b) Incoming: - (i) MCCB 4 pole, 415 Volts, 50 Hz AC grade, 320 Amps, 36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. (ii) Digital Load Manager multi-functional Energy Meter having facility to measure - true RMS value, kWH, neutral current for quadrant energy, max demand of kW, kVA, kVAR & Amp, CT operated 415 volts, 50 Hz AC supply including CTs. -01 set. (iii) Indicating lamps (R,Y,B) - 01 set of three Continue....(at Serial Item No. 63.01)
Continue....(from Serial Item No. 63.00) (c) Outgoing (i) MCCB 4 pole, 415 Volts, 50 Hz AC grade, 200 Amps, 36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. (ii) MCCB 4 pole, 415 Volts, 50 Hz AC grade, 160 Amps, 27 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. (iii) MCCB 4 pole, 415 Volts, 50 Hz AC grade, 63 Amps, 16 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. (iv) On-load change over switch 250 Amp, 4 pole, 415 volt, 36KA - 01 No. Note: - (i) All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (iii) Panels shall be placed above 0.45 metre from ground level (iv) Outgoing Cables shall be fed with solid busbar connectors.
Repair of APFC (Automatic Power Factor Correction) panel of capacity 25 to 150 kVAR (kilovolt-amperes reactive) by replacing of unserviceable part including replacement of wiring with copper conductor cable with lugs etc, calibration of relays, digital meters complete all as specified and directed. Note : Unserviceable spare parts will be measured & paid separately under respective items of BOQ.
Supply only power capacitor of 5 KVAR, cylindrical type, suitable for existing APFC panel complete including removal of old unserviceable capacitor complete all as specified and directed.
Supply only power capacitor of 10 KVAR, cylindrical type, suitable for existing APFC panel complete including removal of old unserviceable capacitor complete all as specified and directed.
Supply only power capacitor of 20 KVAR, cylindrical type, suitable for existing APFC panel complete including removal of old unserviceable capacitor complete all as specified and directed.
Supply only power capacitor of 25 KVAR, cylindrical type, suitable for existing APFC panel complete including removal of old unserviceable capacitor complete all as specified and directed.
M&L for finding electrical fault in underground cable using fault locating machine as per site requirement for LT cables of any type/size complete all as specified and directed.
M&L for shifting of LT panel of any size, from one location to another location (in Zone-III area) including replacement of old luxs on any type/size of cable, disconnecting and making all electric connection and including PCC foundation of 1:3:6 type C1 using 20 mm graded stone aggregate as per site requirement and testing complete all as specified and directed.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core complete all as specified and directed. Note : Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note : Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core complete all as specified and directed. Note - Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core complete all as specified and directed. Note - Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
S&F steel tubular swaged pole 410 SP 31 (9 meters long) complete with cast iron base plate, finial, taper plug, nuts, bolts and washers all as specified including painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing complete embedded portion will be painted with two coat of black bituminous paint complete all as specified and directed. Note : Excavation, earthwork & PCC in foundation and coping shall be measured and paid seperately.
S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections (untested quality) including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply, stringing and fixing of aluminium conductor steel reinforced (ACSR ) including binding and with suitable size of binding wire , connectors, clamps etc. complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Dismantling of ACSR or AAC conductors complete all as specified and directed.
S&F in repair MCCB 4 pole, 125 Amps, 16 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
S&F in repair MCCB 4 pole, 100 Amps, 16 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
M&L in repair for earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:3:6) type B-1 using 20mm graded stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm bore GI Pipe medium grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. Note :- 1. PCC Chammer shall be constructed atleast 2.5 metre away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner. 2. GI wire and protection pipe upto 7.5 meter from the earth plate electrode is deemed to be included in quoted rate. 3. Excavation for earthing to be done manually and Earth resistance below 3 Ohm should be obtained after measurement for every pit.
M&L in repair for earthing with galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below Ground level, connected to GI strip 32x6 mm (up to 7.5 metre) by means of GI nuts, bolts & washers , earth strip protected with & including 40 mm dia light grade GI pipe (up to 7.5 metre) all as shown in electrical plate No 3 of MES Schedule Part I, with & including PCC 1:3:6 type C1 for pit with cover of 50 mm thick RCC 1:1.5:3 type A1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20 mm GI medium grade pipe , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed. Note :- 1. The insulation procedure shall be followed as per instruction of the earth electrode manufacturer. 2. GI pipe of suitable size for protection against mechanical damage of main earth strip from earth electrode to test point up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the quoted rate. GI strip & GI protection pipe beyond 7.5 metre shall be measured & paid separately. 3. If desired earth resistance is not obtained during testing ,the earthing shall be re-done with out any extra cost.
Earth continuity conductor or main earthing lead fixed to wall, on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 mm GI strip complete all as specified and directed.
S&F in repair Junction box, size 260x210x116 mm, thermoplastic polystyrene unbreakable suitable for pole mounted outdoor type IP-65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R,Y,B terminals, including one MCB SP 06 amp 10 kA, all duly fixed on din channel, cable glands for cable entry complete all as specified and directed.
S.R.Enterprises (BID ID -3448704)
LAKSHMI ASSOCIATES (BID ID -3448099)
SHREE BHAGWATI ENTERPRISES (BID ID -3454394)
DIVYA ASSOCIATES (BID ID -3454537)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
8922Tender.pdf
Tender Documents • 0.77 MB
BOQ_819424.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .