Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-Finance | ₹6.2 Cr | L1 | Accepted-Finance Qualified for Award of Contract |
| 2 | L2₹7.4 Cr+₹1.2 Cr (18.6%)Rejected-Finance | ₹7.4 Cr+₹1.2 Cr (18.6%) | L2 | Rejected-Finance Not Qualified for Award of Contract |
| 3 | L3₹7.6 Cr+₹1.4 Cr (22.2%)Rejected-Finance | ₹7.6 Cr+₹1.4 Cr (22.2%) | L3 | Rejected-Finance Not Qualified for Award of Contract |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical 201 202 LALA 1 LANDMARK MG ROAD HYDERABAD HYDERABAD | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SKY ENGINEERING INTERIORS L3 | Touchstone Infrastructure and Solutions Private Limited L2 | Aarthi Constructions L1 |
|---|---|---|---|---|---|---|
| 1.00Interior | ||||||
| 1.00Partitions | ||||||
| 1.00Drywall solid partition system | ||||||
| 1.00 | 97.0mm thick Gypwall Habito partition consist of Metal framework having maximum reachable height of 3600mm satisfying L/240 criterion at 200Pa, possessing fire rating of 60mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 43dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.425W/m²K & Heavy duty rating as per BS 5234 part. Partition comprises of single layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes single layer of 12.5mm thick ®Habito conforming to IS 2095 Part 1:2011 / EN 520: 2004 - Type A,D,R,I,HB having flexural strength – {Longitudinal > 1010N & transverse > 550N} on both side of framing. ™ Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm ™ C-Stud with lip of 6.5mm and H-cutout on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 610mm c/c in 72x32x32x0.5mm ™ Floor Channel & 72x32x32x0.5mm ™ Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with ® Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail**, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm ™ Noggin Channel to be fitted at the horizontal joints of board. ®Habito board strip is placed between ceiling channel and soffit when fire rating is more than 30mins ® Boards to be Screw fixed with ®Habito Screw of 25mm with 30nos per m2 at 300mm at centre and 150mm at periphery. 50mm Glass wool of density 20kg/m3 shall be placed in Metal framework with the help of holding Clip. Edges & joints to be finished with ® Pro-Fill JC conforming to ASTM C475 & ®Paper tape. Periphery & cut-outs of the partition to be treated with suitable Fire & Acoustic Sealant. All the performance test are carried out at NABL accredited/ government approved lab. | 259 | sqm | 12,77,906 ₹15,07,929.08 | 12,78,165 ₹15,08,234.7 | 8,97,953 ₹10,59,584.54 Lowest |
| 1.00Rate to include provisions to be made for fixing writing boards and soft board fabrics on to it. Rate to include on coat of altek patty and two coats of acrylic emulsion paint finish all complete. Rate to also include 50mm high aluminium skirting from JEB or Bottomline. | ||||||
| 1.01Rate to include cutouts with necessary support frames for services such as HVAC ducting, return air, and fresh air. No additional cost to be claimed for the same | ||||||
| 1.01Wall lining with Habito beside block wall for better thermal insulation and acoustic performance | ||||||
| 1.01 | 62.5mm(Min.) thick Wall lining with C-stud partition which includes single layer of tapered edge 12.5mm thick ®Habito conforming to IS 2095 Part 1:2011 / EN 520:2004 - Type A,D,R,I,HB having flexural strength – {Longitudinal > 1010N & transverse > 550N} of size 1219x2438mm mm
screw fixed to C-stud which is placed adjacent to brick/RCC wall. 48x0.5mm ™ C-stud {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610mm c/c in 50x0.5mm ™ {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961} floor and ceiling channel. Floor & Ceiling channel is anchored to the floor & True ceiling using ® Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti Nail anchor fasteners at 600mm c/c in centreline manner. A ™ Noggin channel {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of outer boards. Single layer of ® boards to be screw fixed with ® drywall screws of 25mm at minimum spacing of 300mm at centre and 150mm at periphery. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with ® Pro-Fill Jointing compound Air Dry (Conforms to ASTM C475), ® Joint Paper tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Acoustic sealant. All other detailing and specifications to be followed as per approved drawing of . | 65 | sqm | 1,62,045 ₹1,91,213.1 | 1,56,455 ₹1,84,616.9 | 1,19,145 ₹1,40,591.1 Lowest |
| 1.01Vertical drop partitions till lintel level - From 2.7m to 3.8m level, bottom of true roof slab. | ||||||
| 1.01 | Supply and fixing vertical drop partitions from slab bottom at 3.8m level till lintel of item no's 5 & 6 The vertical drop to be made up of 50 x 25 mm aluminium section framework at every 600mm c/c and to be strengthened appropriately with anchorfastners to the slab soffit and the civil walls at the ends. Note that the vertical drops are to be sturdy enough to hold the TG glass partition with aluminium framework. The vertical drop frame to be panelled with 2x12.5mm gypsum board on both sides of the framework. All joints and gaps to be sealed with silicon sealant to make the partition air tight. | 98 | sqm | 3,97,390 ₹4,68,920.2 | 3,60,640 ₹4,25,555.2 | 3,54,270 ₹4,18,038.6 Lowest |
Tender Value
Refer Docs
EMD Value
₹12.5 L
Closing Date
13 Jan 2026, 3:00 pmClosed
The Head (Project Purchase) The Head (Project P
The Head (Project Purchase) ICSR, IITM, Chennai-36
TOTAL TURNKEY INTERIOR FIT OUT WORKS IN THE EIGHTH FLOOR (B- BLOCK) IITMRP
2025_IITM_259168_1
ED/8106/223/INTERIORFIT
Open Tender
Miscellaneous Works
Works
21 days
Eighth Floor (B- Block) At Research Park, IIT M
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹12.5 L
Yes
Please refer to the tender document
18 Feb 2026
16 Dec 2025
14 Jan 2026
16 Dec 2025
13 Jan 2026
23 Dec 2025
22 Dec 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Interior | - | - | - | - |
| - | Partitions | - | - | - | - |
| - | Drywall solid partition system | - | - | - | - |
| - | 97.0mm thick Gypwall Habito partition consist of Metal framework having maximum reachable height of 3600mm satisfying L/240 criterion at 200Pa, possessing fire rating of 60mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 43dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.425W/m²K & Heavy duty rating as per BS 5234 part. Partition comprises of single layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes single layer of 12.5mm thick ®Habito conforming to IS 2095 Part 1:2011 / EN 520: 2004 - Type A,D,R,I,HB having flexural strength – {Longitudinal > 1010N & transverse > 550N} on both side of framing. ™ Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm ™ C-Stud with lip of 6.5mm and H-cutout on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 610mm c/c in 72x32x32x0.5mm ™ Floor Channel & 72x32x32x0.5mm ™ Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with ® Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail**, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm ™ Noggin Channel to be fitted at the horizontal joints of board. ®Habito board strip is placed between ceiling channel and soffit when fire rating is more than 30mins ® Boards to be Screw fixed with ®Habito Screw of 25mm with 30nos per m2 at 300mm at centre and 150mm at periphery. 50mm Glass wool of density 20kg/m3 shall be placed in Metal framework with the help of holding Clip. Edges & joints to be finished with ® Pro-Fill JC conforming to ASTM C475 & ®Paper tape. Periphery & cut-outs of the partition to be treated with suitable Fire & Acoustic Sealant. All the performance test are carried out at NABL accredited/ government approved lab. | 259 | sqm | - | - |
| - | Rate to include provisions to be made for fixing writing boards and soft board fabrics on to it. Rate to include on coat of altek patty and two coats of acrylic emulsion paint finish all complete. Rate to also include 50mm high aluminium skirting from JEB or Bottomline. | - | - | - | - |
| - | Rate to include cutouts with necessary support frames for services such as HVAC ducting, return air, and fresh air. No additional cost to be claimed for the same | - | - | - | - |
| - | Wall lining with Habito beside block wall for better thermal insulation and acoustic performance | - | - | - | - |
| - | 62.5mm(Min.) thick Wall lining with C-stud partition which includes single layer of tapered edge 12.5mm thick ®Habito conforming to IS 2095 Part 1:2011 / EN 520:2004 - Type A,D,R,I,HB having flexural strength – {Longitudinal > 1010N & transverse > 550N} of size 1219x2438mm mm
screw fixed to C-stud which is placed adjacent to brick/RCC wall. 48x0.5mm ™ C-stud {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610mm c/c in 50x0.5mm ™ {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961} floor and ceiling channel. Floor & Ceiling channel is anchored to the floor & True ceiling using ® Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti Nail anchor fasteners at 600mm c/c in centreline manner. A ™ Noggin channel {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of outer boards. Single layer of ® boards to be screw fixed with ® drywall screws of 25mm at minimum spacing of 300mm at centre and 150mm at periphery. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with ® Pro-Fill Jointing compound Air Dry (Conforms to ASTM C475), ® Joint Paper tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Acoustic sealant. All other detailing and specifications to be followed as per approved drawing of . | 65 | sqm | - | - |
| - | Vertical drop partitions till lintel level - From 2.7m to 3.8m level, bottom of true roof slab. | - | - | - | - |
| - | Supply and fixing vertical drop partitions from slab bottom at 3.8m level till lintel of item no's 5 & 6 The vertical drop to be made up of 50 x 25 mm aluminium section framework at every 600mm c/c and to be strengthened appropriately with anchorfastners to the slab soffit and the civil walls at the ends. Note that the vertical drops are to be sturdy enough to hold the TG glass partition with aluminium framework. The vertical drop frame to be panelled with 2x12.5mm gypsum board on both sides of the framework. All joints and gaps to be sealed with silicon sealant to make the partition air tight. | 98 | sqm | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 25.95 MB
tenderdcm.pdf
Tender Documents • 25.91 MB
BOQ_299424.xls
BOQ • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .