Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.9 LAdmitted-Finance | -28.00% | ₹16.9 L | L1 | Admitted-Finance |
| 2 | L2₹18.1 LAdmitted-Finance | -22.99% | ₹18.1 L | L2 | Admitted-Finance |
Tender Value
₹23.5 L
EMD Value
₹47,040
Closing Date
5 Mar 2026, 5:00 pmClosed
SE TW ajmer
Room No. 216, 2nd Floor, Vidyut Bhawan, Panchsheel Nagar, Makarwali Road, Ajmer- 305004
Construction of 33/11 KV GSS alongwith associated 33 and 11 KV lines works under Ghatol Sub-Division of Banswara circle Ajmer Discom on Labour Rate Basis
2026_AVVNL_539133_1
AJD /SE(TW)/TN-460/Lot-1
Open Tender
Electrical Works
135 days
Office of Superintending Engineer TW Vidyut Bhawa
as per specification
3 documents required · 3 mandatory
₹2,950
Sr. Accounts Officer (EA and Cash)
₹47,040
17 Mar 2026
16 Feb 2026
6 Mar 2026
16 Feb 2026
5 Mar 2026
16 Feb 2026
16 Feb 2026 - 27 Feb 2026
Construction of 33/11KV GSS
Levelling of ground
Levelling of ground up to 30 cm.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)
Levelling of ground above 30 cm.to 90 CM.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)
Trimming of tree branches/plants and preparing route approchases for proposed line.
Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
9 Mtr/ 1.2mx0.6mx1.50 m deep
(C)Stay set/Depth of pit
Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms .Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.
Hard/dense soil
Hard soil mixed with boulders
Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken) in foundation plinth excluding the cost of shuttering using 1 cement : 5 sand : 10 aggregate mix. Note : 1. The rates are all lead of cement, lime, ballast, sand, surkhi and grit etc. at site of work. 2. For all concrete work coarse sand shall be used no extra will be paid . 3. Concrete mix prepared by power driven mechanical mixer shall be used . 4. Under exceptional coditions, where mechanical mixer and vibrator are not used (with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator. 5. Thickness of the cement concrete should not exceeed 100 mm.
Plaster on new surface on walls in cement, sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick. Note : 1. The rates for complete work including racking of joints, curing, grinding, mixing and finishing T&P and scaffolding material and cost of material with all lead and lift. 2. The rates cover protection of all place and things, requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.
Cement concrete flooring grade 1:2:4 (1-cement :2- coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc. complete. Note : 1. The rates for all items inculde all form of work, laying, curing and finishing etc. The rates are for complete work at site, inclusive of all leads. 2. The rates cover the preparation and cleaing of all places
25 mm thick with 12.5 mm thick nominal size aggregate.
75 mm thick with 20 mm thick nominal size aggregate.
Masonry for foundation and plinth
Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.
Brick masonry for foundation and plinth in Cement sand mortar 1:6 ( 1 Cement : 6 Sand ) including labour charges.
Safe carriage of PCC poles including loading / un-loading
a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
c) 9 Mtr.long 200 Kg. PCC pole
within 10 Kms.-
Above 10 Km. & upto 30 Km. add for each Km. or part thereof
Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or partthereof.
Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or part thereof.
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms or part thereof.
Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site(b) 25 & 40 KVA
Within 10 Kms.
Above 10 Kms. & upto 30 Kms Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or part thereof.
Safe Carriage of 33/11 KV Power Transformer (b) Above 1.6 MVA & Upto 3.15 MVA
Within 10 Kms
Above 10 Kms & upto 30 Kms . Add for each Km or partthereof
Above 30 Kms & upto 50 Kms . Add for each Km or partthereof
Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores
Within 10 KMs.
Above 10 Kms. and upto 30 Kms.Add per each km,or part thereof
Above 30 Kms. and upto 50 Kms.Add per each km,or part thereof
Safe loading of power/ distribution transformer.
Above 1.6 MVA & upto 3.15 MVA
Safe unloading of power/distribution transformers
Above 1.6 MVA & upto 3.15 MVA
Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
PCC Poles 9 Mtr. Long (400 Kg)/200 Kg
PCC Poles 9 Mtr. Long(200Kg.)
Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
PCC Poles 9 Mtr. Long(400 Kg.)/11Mtr.long
Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
6"x5/8" with 7/10 SWG stay wire
Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.
Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.
Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.
Fixing of 33kv pin insulator with pins.
Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates. (B)G.O. switch . without earthing blade.
33kv G.O.switch
11kv G.O.switch
Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
33kv Horn Gap fuse set.
11kv Horn Gap fuse set.
Installation of lightening arrestors on erected structure /support (set of 3 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates, (A)sub-station type
33 KV L.A. set ( 1set=3 Nos)
11 KV L.A. set ( 1set=3 Nos)
Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,
25 and 40 KVA
Fixing of danger plates on supports/structure
Fixing of PG clamp of Weasel /Rabbit Conductor
Fixing of PG clamp of Dog /Racoon Conductor
Assembly,installation & commisioning of 11 KV Roaster switchs on erected structures with stting for accurate operation including fixing of allied accessories completed in all respect with post insulators and jumpering on both ends for connection with systm.The nuts & bolts will be supplied by contractor for which payment will be made as per prevailing Dicom store issue rates.
Three no. Earthing of 11/0.4 KV distribution transformer /sub-station with M.S.Rod 20mm dia each 3 meter long and driving them into earth by mechanical means at a distance as per approved design & drawing & specification.The work includes flattening of top ends of M.S.rod drilling a hole of 9/16" dia.at flattened top and tightening of M.S.flat 50x6mm/25x3 mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with M.S.rods top end hole.The flat will also be welded with M.S.rod.The end will be connected to equipments as under in sequence.
Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:
Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width
Hard Soil
Ordinary rock ( where blasting is not required.)
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.
Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.
Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:
Where drilling is required
Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.
Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.
Earthing of new 33/11 KV S/S with bentonite compound (including material ) involving following activities. (8.5.1 TO 8.5.6 COVERED)
Pipe Earthing for Power Transformer at 33/11KV S/S :- Supply and erection of earthing electrode shall consist of G.I. Pipe 100 mm, of 3 Mtr. Length. The electrode shall be buried as far as practicable 3 Meters below ground level. Wherever possible earth electrodes shall be located as near the water tap, water drain or near down take pipe. Earth electrodes shall not be installed in proximity to a metal fance. It shall be kept clear of the bulidings foundations and in no case it shall be nearer than 2 Mtr. from the outer face of the wall. The electrode shall be surrounded with layer of charcoal dust and salt mixture through out the length. The 100 mm G.I. pipe shall be provided with holes of 12 mm Dia drilled at 75mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a G.I. threaded cap for watering the earth through a pipe. A clamp with pati of 12" of M.S. Flat of size 50x6 mm shall be fixed (Bolted) on the top age of the pipe which in turn shall be connected Neutral/Body of the Power Transformer through M.S. Flat size 50x6 mm. The G.I. cap over the G.I. Pipe shall be housed in a masonry chamber, approximately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC Inspection cover resting over a RCC frame, embedded in masonry.
Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station.The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6.The charges for muffing will be paid extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates. (B) IN RURAL AREA
PCC Poles 9 Mtr. Long
Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.
ACSR Panther
ACSR DOG/RABBIT
Supply, stacking & spreading of stone boulders 40 mm. Mono size.(Less voids 17%)
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.
33 KV VCB/SF-6 Breaker
11 KV VCB (Outdoor )
Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (The CT/PT set will be tested by Discom).
33 KV CT(1 set of 3 Nos.) OR PT Set
11 KV CT(1 set of 3 Nos.) OR PT Set
Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.
12x2.5 Sq.mm.
Installation of metering points on 11 KV Out going feeder at 33/11 KV S/S.(a to g)
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)
On new surface
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)
On new works with two coats.
Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling as per design and drawing.
Other steel items
Drilling of holes in MS Channel / Angle /Flat
15/16" dia holes(23.81 mm dia.)
Transportation of CT/PT set (all size) including loading and unloading from Nigam store to site
(a) Within 10 Kms.
(b) Above 10 Km upto 30 Km. Add for each Km. or part there off
Supply of MS nuts & bolts
Supply of PG Calmps
33 KV Line work Annexure -B
Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.
Trimming of tree branches/plants and preparing route approchases for proposed line.
Excavation of pit in Hard soil
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
9 Mtr/ 1.2mx0.6mx1.50 m deep
(B) Lattice Tower /Size of pit
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
(C)Stay set/Depth of pit
Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
9 Mtr/ 1.2mx0.6mx1.50 m deep
(B) Lattice Tower /Size of pit
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
(C)Stay set/Depth of pit
Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
9 Mtr/ 1.2mx0.6mx1.50 m deep
(B) Lattice Tower /Size of pit
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
(C)Stay set/Depth of pit
Safe carriage of PCC poles including loading / un-loading
a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or partthereof.
Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or part thereof.
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms or part thereof.
Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
Lattice Structure
Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
8"x3/4" with 7/8 SWG stay wire
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.
Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
(B) IN RURAL AREA
ACSR DOG
Fixing of 33kv pin insulator with pins.
Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
(A).In Rural Area
G.I.Earth wire 6 SWG
G.I.Earth wire 8 SWG
Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.
Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
33kv G.O.switch
Supply of MS nuts & bolts
Transportation and Fixing MS nuts & bolts
Supply of PG Calmps
Fixing of PG clamp of Dog /Racoon Conductor
Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling as per design and drawing.
Other steel items
Drilling of holes in MS Channel / Angle /Flat
15/16" dia holes(23.81 mm dia.)
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)
On new surface
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)
On new works with two coats.
11 KV Line work Annexure -C
Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.
Trimming of tree branches/plants and preparing route approchases for proposed line.
Excavation of pit in Hard soil
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
9 Mtr/ 1.2mx0.6mx1.50 m deep
(B) Lattice Tower /Size of pit
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
(C)Stay set/Depth of pit
Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
9 Mtr/ 1.2mx0.6mx1.50 m deep
(B) Lattice Tower /Size of pit
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
(C)Stay set/Depth of pit
Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
9 Mtr/ 1.2mx0.6mx1.50 m deep
(B) Lattice Tower /Size of pit
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
(C)Stay set/Depth of pit
Safe carriage of PCC poles including loading / un-loading
c) 9 Mtr.long 200 Kg. PCC pole
within 10 Kms.-
Above 10 Km. & upto 30 Km. add for each Km. or part thereof
Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or partthereof.
Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms. or part thereof.
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
Within 10 Kms.
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
Above 30 Kms. Add for each Kms or part thereof.
Fixing of 11 KV pin insulator with pins.
Fixing of 11kv B&S /T&C type disc insulator of 11kv lines (each unit consiting of 2nos.disc.& 1set of H/W ) on terminal point including fixing of hardware and strips.
Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing.
Other steel items
Drilling of holes in MS Channel / Angle /Flat
15/16" dia holes(23.81 mm dia.)
Supply of MS nuts & bolts
Transportation and Fixing MS nuts & bolts
Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
Lattice Structure
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.
Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
(B) IN RURAL AREA
PCC Poles 9 Mtr. Long(200Kg.)
Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
PCC Poles 9 Mtr. Long(200 Kg.)
Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
6"x5/8" with 7/10 SWG stay wire
Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
(B) IN RURAL AREA
ACSR DOG
ACSR RABBIT
ACSR WEASEL
INSULATED RABBIT HT/LT
Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)
On new surface
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)
On new works with two coats.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.23 MB
TechnicalSpecificationTN460.pdf
Tender Documents • 1.22 MB
BOQ_961308.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid