GEMC-511687735326006
Awarded to NOVEX HEALTHCARE
₹7.2 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| INTRAVENOUS CANNULA (I. V. CANNULA NO. 20G) | MAKE - SPM MEDICARE & MODEL - ACCUVEIN | - | 150,000 NOS | ₹4.79 | 718,500 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.2 LQualified Make: accuvein
Model: MAKE - SPM MEDICARE & MODEL - ACCUVEIN NOVEX HEALTHCARE SCO 4 1ST FLOOR INDUSTRIAL AREA PHASE 2 CHANDIGARH 160 002 U T CHANDIGARH CHANDIGARH 160002 | CHANDIGARH | CHANDIGARH | 160002 | Make: accuvein
Model: MAKE - SPM MEDICARE & MODEL - ACCUVEIN | L1 | Qualified | |
| 2 | L2₹7.3 L+₹15,000 (2.09%)Qualified Make: accuvein
Model: INTRAVENOUS CANNULA 20G WITH WINGS WITH PORT MAIN ROAD NEW DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: accuvein
Model: INTRAVENOUS CANNULA 20G WITH WINGS WITH PORT | L2 | Qualified | |
| 3 | L3₹7.3 L+₹16,500 (2.30%)Qualified Make: accuvein
Model: ACCU-VEIN 20G KANPUR ROAD LUCKNOW UTTAR PRADESH 226012 INDIA | LUCKNOW | UTTAR PRADESH | 226012 | Make: accuvein
Model: ACCU-VEIN 20G | L3 | Qualified | |
| 4 | L4₹7.5 L+₹30,000 (4.18%)Qualified Make: Polymedicure
Model: Polymed I V Cannula POLYFLON SCO 159 SECTOR 23 POST OFFICE SECTOR 24D CHANDIGARH CHANDIGARH 160023 | CHANDIGARH | CHANDIGARH | 160023 | Make: Polymedicure
Model: Polymed I V Cannula POLYFLON | L4 | Qualified | |
| 5 | L5₹8.0 L+₹76,500 (10.6%)Qualified Make: LA-MED
Model: LAMED HEALTHCARE PVT LTD 1730 5 SHOP NO 17 RAM GALI BHAGIRATH PALACE CHANDNI CHOWK CHANDNI CHOWK CENTRAL DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | Make: LA-MED
Model: LAMED HEALTHCARE PVT LTD | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Jul 2018, 12:00 pmClosed
intravenous cannulas Intravenous Cannulas ( 150000 ) Technical Specifications Specification Specification Name Values Allowed Values Performance Parameters Conforming standards for the I V Canulla IS/ISO 10555-5 IS/ISO 10555-5 Whether IV Canulla is with safety features for preventing needle stick injuries true Flowrate of inside Catheter in ml/min as per IS/ISO 10555-5 65 - Needle Point Finish Long bevel cut Long bevel cut Needle Hub Complying with ISO 594-1 Complying with ISO 594-1 Needle hub fitting with 6% luer Taper true Injection Port With With Wings With With Luer Lock Plug/Cap true Disposable Yes - Radio opaque line feature true true Shelf Life (years) 5 - 1/4 Removable Vent Fitting Yes - Sterile Yes - Non-Toxic and Non- Pyrogenic Yes - Provision for Recalling product yes - Dimensional and Material Parameters Material of Needle Stainless Steel Complying with ISO 9626 - Material of Catheter Polytetrafluoroethylene (PTFE) Polytetrafluoroethylene (PTFE)
Flourinated Ethylene Propylene (FE P)
Polyurethane
NA
Vial on biomaterial Nominal outside Diameter of catheter tube and color coding as per IS/ISO 10555-5 Pink - 20G Pink - 20G Effective Length of Catheter Tube in mm as per IS/ISO 10555-5 - - PACKING PARAMETERS Type of packing blister packing - Packing as per specification and provision of Drug & cosmetic act. yes - All supplies shall have a remaining self life at least five by six (5/6) of the stipulated shelf life at the time of delievery yes - CERTIFICATE AND REPORTS Availability of valid drug licence yes - Drug License no & Date of manufacturers and in case of resller
Drug License no & Date (for sale) of Authorized reseller also to be indicated - - Manufacturers and the Seller must not be under Conviction in terms of provisions of Drug and Cosmetic act yes - Availability of Latest non conviction certificate issued by concerned Drug yes - 2/4 authorities Availability of Certificate for Manufacturing such as GMP under revised Schedule-`M' of Drugs & Cosmetics Act 1940 Or WHO-GMP or COPP for imports. yes - Details of above Mentioned Certificate such as Type of certificate
Number
date and validity - - Availability of any other certification such as CE/FDA/CSA/PQS/ISO etc… true - Details of the above mentioned such as Type of certificate
date and validity
if Yes otherwise indicate NA - - Copies of batch in house Test report to be forwarded with each supply yes - Copies of certificates to be provided to buyer on demand after placement of order yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kul Bhushan 160031
Government Medical College & Hospital Sector 32
Chandigarh
160031 150000 40 Required No ePBG Required No
282153
GEM/2018/B/40053
GeM Contract
intravenous cannulas
GeM Contract
40 days
Chandigarh; Chandigarh
PRODUCT
Awarded to NOVEX HEALTHCARE
₹7.2 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| INTRAVENOUS CANNULA (I. V. CANNULA NO. 20G) | MAKE - SPM MEDICARE & MODEL - ACCUVEIN | - | 150,000 NOS | ₹4.79 | 718,500 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| intravenous cannulas Intravenous Cannulas ( 150000 ) Technical Specifications Specification Specification Name Values Allowed Values Performance Parameters Conforming standards for the I V Canulla IS/ISO 10555-5 IS/ISO 10555-5 Whether IV Canulla is with safety features for preventing needle stick injuries true Flowrate of inside Catheter in ml/min as per IS/ISO 10555-5 65 - Needle Point Finish Long bevel cut Long bevel cut Needle Hub Complying with ISO 594-1 Complying with ISO 594-1 Needle hub fitting with 6% luer Taper true Injection Port With With Wings With With Luer Lock Plug/Cap true Disposable Yes - Radio opaque line feature true true Shelf Life (years) 5 - 1/4 Removable Vent Fitting Yes - Sterile Yes - Non-Toxic and Non- Pyrogenic Yes - Provision for Recalling product yes - Dimensional and Material Parameters Material of Needle Stainless Steel Complying with ISO 9626 - Material of Catheter Polytetrafluoroethylene (PTFE) Polytetrafluoroethylene (PTFE) | - | - | - |
| Flourinated Ethylene Propylene (FE P) | - | - | - |
| Polyurethane | - | - | - |
| NA | - | - | - |
| Vial on biomaterial Nominal outside Diameter of catheter tube and color coding as per IS/ISO 10555-5 Pink - 20G Pink - 20G Effective Length of Catheter Tube in mm as per IS/ISO 10555-5 - - PACKING PARAMETERS Type of packing blister packing - Packing as per specification and provision of Drug & cosmetic act. yes - All supplies shall have a remaining self life at least five by six (5/6) of the stipulated shelf life at the time of delievery yes - CERTIFICATE AND REPORTS Availability of valid drug licence yes - Drug License no & Date of manufacturers and in case of resller | - | - | - |
| Drug License no & Date (for sale) of Authorized reseller also to be indicated - - Manufacturers and the Seller must not be under Conviction in terms of provisions of Drug and Cosmetic act yes - Availability of Latest non conviction certificate issued by concerned Drug yes - 2/4 authorities Availability of Certificate for Manufacturing such as GMP under revised Schedule-`M' of Drugs & Cosmetics Act 1940 Or WHO-GMP or COPP for imports. yes - Details of above Mentioned Certificate such as Type of certificate | - | - | - |
| Number | - | - | - |
| date and validity - - Availability of any other certification such as CE/FDA/CSA/PQS/ISO etc… true - Details of the above mentioned such as Type of certificate | - | - | - |
| date and validity | - | - | - |
| if Yes otherwise indicate NA - - Copies of batch in house Test report to be forwarded with each supply yes - Copies of certificates to be provided to buyer on demand after placement of order yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kul Bhushan 160031 | - | - | - |
| Government Medical College & Hospital Sector 32 | - | - | - |
| Chandigarh | - | - | - |
| 160031 150000 40 Required No ePBG Required No | - | - | - |
Exempted
10 Jul 2018
3 Jul 2018
contract_GEMC-511687735326006.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_282153.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .