Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.6 L+₹4.6 L (19.9%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹29.9 L+₹7.0 L (30.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹31.0 L+₹8.0 L (34.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹35.2 L+₹12.2 L (53.1%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-AOC L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Aug 2023, 6:00 pmClosed
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Repair replacement of external water supply system, U/S CI/DI/GI distribution pipe lines RO plants including connected accessories at RMS Dholpur
2023_MES_603992_2
8262/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹70,000
Yes
22 Sept 2023
25 Jul 2023
16 Aug 2023
25 Jul 2023
14 Aug 2023
1 Aug 2023
26 Jul 2023 - 28 Jul 2023
Amount
M&L for attending complaint for water leakage complaint in under ground flange end CI/DI/GI pipe from size 80mm to 150mm including including necessary excavation in mud, in any type of soil by manual or using special T &P etc. De-watering from the trenches by using pump sets, rectification of leakages, dismantling and removing U/S joints of rubber gasket or fibre board gaskets for spigot and socket pipe and replace jointing with new fibre or rubber gasket of the following size complete all as specified and directed.
80mm dia
100mm dia
150mm dia
Notes for Sl item No 1 (a) The contractor will be alloted complaints at MES complaint cell on as requirement basis on all working days and sufficient tradesman /plumber/ resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scatteredRMS Dholpur. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M/JE E/M Dholpur and the same shall be submitted to Dholpur MES store yard on daily basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares including fittings as required at site to be replaced and shall be measured and paid separately under respective items.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying pipeline & cable, and getting out in soft disintegrated rock/any type of soil complete all specified and directed.
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all specified and directed.
Removing excavated soil at a distance not exc 50 m and deposited where directed complete all specified and directed.
M&L for PCC 1:3:6 type C-1(using 20 mm graded stone aggregate) work for pedestal pillars, foundations, coping and other misc supports to external water supply installations including form work including demolition of existing PCC of any type etc complete all specified and directed by Engineer in Charge.
M&L walling of squared rubble uncoursed, stone masonry well bonded, bedded and solidly hearted built in cement mortar 1:4 for pipeline pedestal supports including dismantling of existing mesonary complete all as specified and directed by Engr-in-Charge.
Supply and fixing of GI water tubing IS-1239 marked, medium grade including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviciable pipe of the following sizes :- Note :-Excavation earth work will be measured and paid saperatly under respective item of BOQ.
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80 mm bore
100 mm bore
M &L in replacement of GI flanged pipe of 80mm dia medium grade IS-1239 marked complete with rubber gasket nuts, bolts and washers lowering in open well/bore well complete all specified and directed. (Make : Jindal/ Prakash surya/ Tata). Note :- Each pipe is in the 3m length as required at site.
M&L for jointing and testing of all kind of DI (Ductile Iron) pipe, round flanged end on both sides of 100 mm dia , K-9 complete with rubber gasket nuts, bolts and washers inside OPC coated, white painted inside and black painted on out side complete all as specified and as directed. (Make : Jindal/ Electro Steel/ Tata).
Supply and fixing in replacement of sluice valves of cast iron body with forged brass spindle, class PN 1.6 and cast iron wheel head, both ends flanged, IS-1486 marked complete with neoprene rubber gasket joints, nuts, bolts (high tensile), and washers etc complete all as specified and directed (Make : Upadhyay/ Kejriwal iron and steel works/ Kirlosker/Bir/L&T) of following size:-
150mm bore flanged end.
100mm bore flanged end.
Supply and fixing in replacement of non return valve, flanged ends PN 1.0 ISI marked of 100mm bore complete all specified and directed. (Make : Upadhyay/ Kejriwal Iron and steel work/ Kirloskar/ Bir/L&T).
Supply and fixing in replacement of cast iron Air Release Valve flanged type, PN-1.0 suitable of size 100mm raising main with complete parts incl wheel etc, flanged type complete all specified and directed. Make-Upadhyay/Kejriwal iron
Supply and fixing of high density poly ethylene (HDPE) pipe of pressure rating 6 kgf/cm2 fixed complete to wall ,ceiling ,floor or in trenches including all fittings all as specified and as directed by engineer-in-charge for the following sizes:-
50mm dia
25mm dia
Supply and fixing the following PP-R gate valves( brass insert) as per requirement including removing old unserviceable ones complete all specified and directed. Make : SFMC/ SUPREME or Equivalent Make.
PP-R valve 50 mm outer dia .
PP-R valve 25 mm outer dia .
PP-R valve 20 mm outer dia .
S&F in replacement gun metal gate valve with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, ISI marked of following sizes complete all specified and directed.
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
S&F in replacement ball valves/float valve, high pressure with polyethelene float and flynut complete screwed for iron pipes of following sizes complete all specified and directed. :-
20mm dia
25mm dia
S&F in repair of MS nuts, bolts , washer & MS flat, machine cut, hexagonal 5cm to 10cm long, dia meter of neck 16 to 20mm or existing size as per site requirement and complete.
S & F in repairs of MS clamp /saddle piece made out of MS flat iron suitable to make ferrule and clamping for branch connections complete with GI socket welded it on one FI strip suitably positioned at the centre of pipe complete with MS nuts, bolts, washers (02 Nos) and rubber packing for complete for following sizes of pipe:
100mm bore.
80mm bore.
M&L for Cutting anxious green growth / vegetation growth from root for cleaning out the area around OH tank / pump house No----1, 2 & 3 at Gundrai and kesharbagh substation , Kesarbagh sump house and at ground level by cutting up root, un- wanted plants / bushes and removal the same to a distance not less than 50 mtr complete all specified and directed by engineer -in -charge , Note: (i) Cost of Cutting T&P, transporting / disposal / dumping away from the site as per the laid down procedure of waste management system deemed to be included in quted rate. (ii) Entire site shall not be given for one time. Area for cleaning shall be given to the contractor on requirement basis as per the site conditions and growth rate of bushes and grass etc. The area shall be divided into several parts and shall be directed to the contractor when cleaning is required at site.
Cutting existing water supply pipe line with the help of electric cutting tools or manually for repairing such as jointing, blockage removal, cleaning of particular joint etc and making good after repairing (of size 50mm to 150mm) complete all specified and directed..
Dismantling of defective sluice valve for repairs such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc complete all as specified and directed of following sizes:-
80 mm bore.
100 mm bore.
150mm bore.
Drilling and tapping CI/GI water mains (in position) for branch connection of the internal dia of the following size complete all specified and directed:-
15mm dia
20mmdia
Cutting existing water supply pipe line for alterations and addition in length and screwing/threading or lengthening the screw on pipe form connection and refixing etc for the following size complete all specified and directed:
15mm dia
20mm dia
Labour only for servicing of industrial RO Plant installed at academic complex including back washing, cleansing the filter medium, resetting all TDS upto the recommended level by PHED, checking all valves, servicing the turbo jet motor for raw water, checking and tighting all mounting brackets, nuts. Bolts etc. removing fungus by cleaning of raw water and filtered water storage tank complete all specified and directed by Engineer-in-Charge. Note: (i) Technician should be hired from reputed company of the RO plant. No extra allowance shall be be given to the technician. Conveyance to the technician shall be of ararnged by the contractor only. No vehicle shall be provided for the conveyance of the technician by MES. (ii) Spare parts /fittings fixtures, if required to replace shall be measured and paid seperately under respective item of BOQ.
Supply only of the following spare parts of RO plant of capacity 200LPH installed at academic complex :-
Primary sediment cartridge Filter
Secondary sediment cartridge Filter
RO membrane as per the existing make and model suitable for 200LPH capacity
Rewinding of raw water motor and servicing of pumpassembly of capacity 2HP
PCB control panel with LED display and mounting accessories and testing etc
M&L for PVC circular tank (cylidrical and placed vertical) in replacement of RO plant raw water and filtered water storage of capacity 1000 ltrs, white colour including making hole for pipe connection with washers and nipple of suitable size complete all as specified and directed by Engr-in-Charge.
Supplying and laying of CPVC pipes SDR-11 & plain CPVC SDR-11 fittings in tenches complete all as specified and as directed.
All as per item No 27 here in before but of outer dia size 25mm
All as per item No. 27 here in before but of outer dia size 50mm
S&F of the following accessories of CPVC pipes and RO plant and other installations associated with external water supply:
Water level sensor device with sensing cable twin core copper flexible upto 10mtr length x 2 run from PCB control panel to PVC tanks
Brass elbow 20mm outer dia
Reducer brass elbow 3/4 x 1/2'' (20mm x15mm) outer dia
Brass Tee 20mm outer dia
Male brass threaded adapter 20mm outer dia
Male brass threaded adapter 25mm outer dia
Male brass threaded adapter 40mm outer dia
Female brass threaded adapter 20mm outer dia
Female brass threaded adapter 25mm outer dia
Female brass threaded adapter 40mm outer dia
PVC high density back wash handle assembly as per existing size in carbon chamber in replacement of old one.
Steel nuts and bolts with wasgers of existing size and type
M&L in replacement of provision of brick masonry valve pit chamber of 3mm thick MS sheet and angle iron frame of 40x40mm including black bituminous paint and 1200x1200x1000mm size (internal dimensions) including necessary excavation and earth work and frame with cover complete all as specified and directed.
Collecting water sample in sutiable bottle for testing of bio and chemical each test as per ISO 10500 for the following location complete all as specified and directed.
Pump house
Academic block
Hostel area
Gundrai well
Residential block
Tulsi Enterprises
RAJEEV CONSTRUCTION
Rajesh Mishra
Vijay Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .