Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.3 LAccepted-AOC | ₹9.3 L | 1 | Accepted-AOC AOC |
| 2 | 2₹10.2 L+₹90,050 (9.66%)Rejected-Finance HOUSE NO 1310 SECTOR 4 URBAN ESTATE GURUGRAM 122001 | GURUGRAM | HARYANA | 122001 | ₹10.2 L+₹90,050 (9.66%) | 2 | Rejected-Finance 2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹8.0 L
EMD Value
₹15,920
Closing Date
4 Feb 2022, 5:00 pmClosed
Vishal Garg
Sector-34
Repairing Servicing Overhauling and commissioning of 200KVA and 315 KVA Transformer in ward 4 Dhundahera and Sector 21 and ward 18 under limit of Municipal Corporation Gurugram.
2022_HRY_205334_1
EE-EEELCT/MCG/2022/3295
Open Tender
Electrical Works
Works
90 days
Repairing Servicing Overhauling and commissioning
Repairing Servicing Overhauling and commissioning of 200KVA and 315 KVA Transformer in ward 4 Dhundahera and Sector 21 and ward 18 under limit of Municipal Corporation Gurugram.
2 documents required · 2 mandatory
₹1,000
₹15,920
1 Jul 2025
25 Jan 2022
5 Feb 2022
25 Jan 2022
4 Feb 2022
25 Jan 2022
Amount
Repairing Servicing Overhauling and commissioning of 200KVA and 315 KVA Transformer in ward 4 Dhundahera and Sector 21 and ward 18 under limit of Municipal Corporation Gurugram.
Painting charge after short blasting from inside & outside of the transformer 315KVA tank having hot oil resistant paint including radiator tubes & conservative tanks & other accessories with suitable primer and two coats of paint on transformer before cleaning of tank with complete all respect.
Magnetic type oil level gage with low level alarm contact complete as per original design of the transformer.
Dehydration and filtration of dirty transformer oil for transformer with dehydration filter machine.
Repair and testing including over hauling of 11kv LT Coil and LT Rod 200 KVA Transformer replacement of its defective coil/rod.
Bushing of required size & design to be used on the primary side of the transformer
Transformer 315KVA tank repairing charge for electrical welding complete all respect.
Transformer 200 KVA tank repairing charge for electrical welding complete all respect.
S/E of XLPE (E)11 KV LT 240 Sq. mm 3 Core PVC aluminum conductor un-armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make- Polycab, Havells, RR, Grandly
Supply and topping of 200 KVA & 315 KVA transformer Silicone Transformer Oil - High Dielectric Strength Fluid in conservator tank and including replacement of dirty silica gel in transformers.
Buy back of old dismantle material (HT & LT coil, Rod, CT & PT, Old HT/LT cable, bushing, valve, gasket etc) with complete all respect.
Painting charge after short blasting from inside & outside of the transformer200KVA tank having hot oil resistant paint including radiator tubes & conservative tanks & other accessories with suitable primer and two coats of paint on transformer before cleaning of tank with complete all respect.
Bushings of required size /design to be used on the secondary side of the transformer
Oil Drain valve, Filter valve and Dial type thermometer of appropriate design with max. Temp. Indicator complete with re-setting device and alarm contactor for transformer 315 KVA etc. with complete all respect
Oil Drain valve, Filter valve and Dial type thermometer of appropriate design with max. Temp. Indicator complete with re-setting device and alarm contactor for transformer 200 KVA etc. with complete all respect
Gas cutting of lit of sealed type transformer of required specification and size as per design of the transformer with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work
Repair and testing including over hauling of 11kv HT Coil and HT Rod for 315 KVA Transformer replacement of its defective coil/rod.
Repair and testing including over hauling of 11kv HT Coil and HT Rod 200 KVA Transformer replacement of its defective coil/rod.
Repair and testing including over hauling of 11kv LT Coil and LT Rod 315 KVA Transformer replacement of its defective coil/rod.
HT tapex type cable boxes of required specification and size as per design of the transformer
Loading and unloading of transformer at both side, hiring of crane, and transportation charges to and fro, Supervision and commissioning charges
Repairing of 11 kv high tension CT & PT meter panel with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work.
S/E of XLPE (E)11 KV HT 95sqmm 3 core aluminum PVC conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make- Polycab,Havells,RR, Grandly
Tapping connections, insulation on tap leads, brazing by silver brazing rod, dressing of tap leads with insulation paper, Star/ Star connection by new EC grade Copper on HV & LV side.
Bharat Pumps and Projects
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .