Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.6 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 1 | Accepted-AOC Being other than L-1 | |
| 2 | 2₹27.5 L+₹2.2 L (8.80%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹27.6 L+₹2.3 L (9.03%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹28.8 L+₹3.5 L (13.8%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹29.6 L+₹4.3 L (17.1%)Rejected-Finance 103 1ST FLOOR PAYAL RIDDHI CHS PLOT NO 51 SECTOR 27 KHARGHAR RAIGAD MAHARASHTRA 410210 | RAIGAD | MAHARASHTRA | 410210 | 5 | Rejected-Finance Being other than L-1 |
| Sl No | Description | Qty | Unit | GUPTA ENGINEERING WORKS L4 | M/s SCHOLASTIC ENTERPRISES L1 | Balaji Associate L7 | H.S.Kochhar n Sons L8 | Manu Enterprises L5 | MUKTA AND COMPANY L2 | FUTURE Inc. L9 | DHARMA ENGINEERS AND CONTRACTOR L3 | M/s Sumer Associates L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing old unserviceable LT Panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical in door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 2 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer ACB/MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job.) The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm. All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly mounted on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :-Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS | 4 | Each Job | 1,68,000 ₹6,72,000 | 1,50,000 ₹6,00,000 | 2,08,000 ₹8,32,000 | 2,25,000 ₹9,00,000 | 1,74,000 ₹6,96,000 | 1,40,000 ₹5,60,000 Lowest | 2,50,000 ₹10,00,000 | 1,50,000 ₹6,00,000 | 1,65,000 ₹6,60,000 |
| 1.01INCOMING MCCB a) 320 Amp 4 pole MCCB 50 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection and rotary handle Ics= 100% Icu-01 Nos. OUTGOING MCCB a) 200 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos. b) 100 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos. c) 125 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos d) Space for spare MCCB - 02 No. Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 No.. c) LED Indicating lamps RYB set of three -01 Sets Note: (a) Cable entry should be incoming/ out going from separate cable gallery. (b) All incoming/outgoing MCCBs shall be provided with suitable size of copper connection plates. (c) All incoming/outgoing MCCBs shall be provided with suitable spreader links – 04 Nos. (d) Provision of gland hole, brass glands and heat shrinkable end joints of all incoming and out going cables all as directed. (e) All incoming/outgoing MCCBs should be marking label/end plate/end clams/ suitable size of terminal block stud/screw less type etc. (f) Main bus bar/ link bus bar should be full covered including back side | ||||||||||||
| 2.00 | Taking down existing old unserviceable LT Panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical in door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 2 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer ACB/MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job.) The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm. All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly mounted on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :-. Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS | 2 | Each Job | 1,36,249 ₹2,72,498 | 1,35,000 ₹2,70,000 | 1,75,000 ₹3,50,000 | 2,00,000 ₹4,00,000 | 1,44,000 ₹2,88,000 | 1,15,000 ₹2,30,000 Lowest | 2,25,000 ₹4,50,000 | 1,15,000 ₹2,30,000 Lowest | 1,38,000 ₹2,76,000 |
| 2.01INCOMING MCCB a) 250 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection and rotary handle Ics= 100% Icu-01 Nos. OUTGOING MCCB a) 100 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos. b) 63 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 03 Nos. c) Space for spare MCCB . Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 No.. c) LED Indicating lamps RYB set of three -01 Sets Note: (a) Cable entry should be incoming/ out going from separate cable gallery. (b) All incoming/outgoing MCCBs shall be provided with suitable size of copper connection plates. (c) All incoming/outgoing MCCBs shall be provided with suitable spreader links – 04 Nos. (d) Provision of gland hole, brass glands and heat shrinkable end joints of all incoming and out going cables all as directed. (e) All incoming/outgoing MCCBs should be marking label/end plate/end clams/ suitable size of terminal block stud/screw less type etc. (f) Main bus bar/ link bus bar should be full covered including back side | ||||||||||||
| 3.00 | Excavating in trenches no exc 1.5m wide and not exc 1.5m in depth for foundation etc or for laying for cables etc not exc 10 sqm on plan and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed. | 470 | Cum | 130 ₹61,100 | 100 ₹47,000 | 99 ₹46,530 | 80 ₹37,600 Lowest | 100 ₹47,000 | 100 ₹47,000 | 200 ₹94,000 | 200 ₹94,000 | 90 ₹42,300 |
| 4.00 | Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in any type of soil complete all as specified and directed. | 420 | Cum | 50 ₹21,000 | 70 ₹29,400 | 40 ₹16,800 | 70 ₹29,400 | 30 ₹12,600 | 30 ₹12,600 | 50 ₹21,000 | 25 ₹10,500 Lowest | 30 ₹12,600 |
| 5.00 | Removing surplus excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. | 50 | Cum | 50 ₹2,500 | 80 ₹4,000 | 55 ₹2,750 | 80 ₹4,000 | 30 ₹1,500 | 30 ₹1,500 | 50 ₹2,500 | 25 ₹1,250 Lowest | 30 ₹1,500 |
| 6.00 | M & L for drilling suitable dia horizontal bore holes for insertion/ laying of 50 to 350 mm bore GI/HDPE tubing of any description below/ under road surface/ floors etc with using mechanical or manual devices as required at site complete all as specified and directed. | 30 | RM | 300 ₹9,000 | 300 ₹9,000 | 250 ₹7,500 Lowest | 300 ₹9,000 | 350 ₹10,500 | 300 ₹9,000 | 300 ₹9,000 | 300 ₹9,000 | 250 ₹7,500 Lowest |
| 7.00 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 160 mm outer dia and 135 mm inner dia complete all as directed. | 440 | RM | 225 ₹99,000 | 200 ₹88,000 | 135 ₹59,400 Lowest | 150 ₹66,000 | 200 ₹88,000 | 220 ₹96,800 | 300 ₹1,32,000 | 245 ₹1,07,800 | 260 ₹1,14,400 |
| 8.00 | All as per item No-7 above but 75mm outer dia and 63 mm inner dia | 1,270 | RM | 80 ₹1,01,600 | 60 ₹76,200 Lowest | 88 ₹1,11,760 | 80 ₹1,01,600 | 90 ₹1,14,300 | 80 ₹1,01,600 | 90 ₹1,14,300 | 75 ₹95,250 | 90 ₹1,14,300 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Sept 2025, 6:00 pmClosed
GE AF Adm Area Agra
GE (AF) Adm Area Agra UP 282008
REPAIR, MAINT, REPLACEMENT OF LT PANELS, SWITCH GEARS AND OTHER ALLIED WORKS IN DOMESTIC AREA UNDER GE (AF) ADM AREA AGRA
2025_MES_729465_1
8000-2291/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Adm Area Agra
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE AF Adm Area Agra
₹80,000
Yes
24 Oct 2025
4 Sept 2025
2 Oct 2025
4 Sept 2025
30 Sept 2025
18 Sept 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .