Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹21.0 L+₹1.1 L (5.33%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹22.4 L+₹2.4 L (12.0%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Being other than lowest bidder | |
| 4 | L4₹25.4 L+₹5.5 L (27.4%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L4 | Rejected-Finance Being other than lowest bidder | |
| 5 | L5₹25.9 L+₹5.9 L (29.7%)Rejected-Finance SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | L5 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jun 2022, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT OF FILTERS V BELTS AND REPLACEMENT OF OTHER MINOR PARTS OF DG SETS AT OLD CORPS AND NEW CORPS SECTOR AREA UNDER AGE EM II OF GE 865 EWS AT LEH
2022_MES_525015_1
865/EWS(NIT-48)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹80,000
Yes
9 Jul 2022
20 May 2022
20 Jun 2022
20 May 2022
18 Jun 2022
4 Jun 2022
Amount
S&F in replacement of flexible fuel pipe with banjo bolt and washer at both side suitable for following capacity DG sets make: Kirloskar/ Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Hose for Air cleaner Suction with complete accessories for following capacity DG Make : Kirloskar/ Cummins/ Greaves Set all as specified and directed by Engineer-in-Charge.
S&F in replacement of Crank wheels for for following capacities of DG Sets make: Kirloskar/ Cummins/Greaves all as specified and directed by Engr-in-Charge
S&F in replacement of Control relays and connected control wirings with AC/DC cables of size for DG Sets digital control monitoring panel of following capacities of DG Sets with complete accessories all as specified and directed by Engineer-in-Charge.-
S&F in replacement of Digital RPM Meter Hours meter with complete accessories for 500 KVA to 750 KVA DG Set make: Kirloskar/ Cummins/Greaves all as specified and directed by Engr-in-Charge
M & L for changing /toping up of engine oil 20W40 for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed. Make:-Veedol/Valvoline/Castrol/Servo.
M & L for changing /toping up of engine oil 15W40 for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed. Make:-Veedol/Valvoline/Castrol/Servo.
Supply & toping up of anti freezing, inhabitor Corrosion (Coolant ) liquid for DG set at various capacity and locations complete all as specified and directed. Make : Indian Oil Corporation/ Valvoline/ Mahindra/ Servo
M&L for disconnecting the U/s alternator Capacity 750KVA 3Phase any make & type from engine, transporting to civil workshop dismantling it for repairing and rewinding by taking out burnt armature winding aligning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves , varnising cotton taping etc, reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engi-in-Charge . Note: Rate are included for replacement of minor parts to make alternator serviceable.
M&L for disconnecting the U/s alternator Capacity 500KVA 3Phase any make & type from engine, transporting to civil workshop dismantling it for repairing and rewinding by taking out burnt armature winding aligning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves , varnising cotton taping etc, reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engi-in-Charge . Note: Rate are included for replacement of minor parts to make alternator serviceable.
M&L for disconnecting the U/s alternator Capacity 280KVA 3Phase any make & type from engine, transporting to civil workshop dismantling it for repairing and rewinding by taking out burnt armature winding aligning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves , varnising cotton taping etc, reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engi-in-Charge . Note: Rate are included for replacement of minor parts to make alternator serviceable.
M&L for disconnecting the U/s alternator Capacity 140KVA 3Phase any make & type from engine, transporting to civil workshop dismantling it for repairing and rewinding by taking out burnt armature winding aligning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves , varnising cotton taping etc, reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engi-in-Charge . Note: Rate are included for replacement of minor parts to make alternator serviceable.
M&L for disconnecting the U/s alternator Capacity 63/62.5KVA 3Phase of approved make & type from engine, transporting to civil workshop dismantling it for repairing and rewinding by taking out burnt armature winding aligning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves , varnising cotton taping etc, reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engi-in-Charge . Note: Rate are included for replacement of minor parts to make alternator serviceable.
S&F in Replacement of thermostate valve for following dg set make Kirloskar /Cummins/Greaves complete all as specified and directed By Engr_in-Charge
750KVA DG set
500 KVA DG Set
280KVA DG Set
160/140KVA DG Set
63/62.5KVA DG Set
S&F in Replacement of Automatic Voltage Regulator (AVR) for following dg set make Kirloskar /Cummins/Greaves complete all as specified and directed By Engr_in-Charge
750KVA DG set
500 KVA DG Set
280KVA DG Set
160/140KVA DG Set
63/62.5KVA DG Set
Repair and servicing cleaning of silensor/exhaust manifold for following dg sets make Kirloskar /Cummins/Greaves all as specified and directred by Engineer-in-Charge.
750KVA DG set
500 KVA DG Set
280KVA DG Set
160/140KVA DG Set
63/62.5KVA DG Set
S&F in Replacement of battery terminal for DG Sets complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Battery lead 2mtr long Red & Black 20mm dis Copper wire with thimble complete as directed by Engineer -in-Charge.
S&F in Replacement battery distilled water for the DG sets complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement battery Batteries Electrolyte for the DG sets complete all as specified and directed by Engineer-in-Charge.
Supply only cotton waste for daily use for cleaning the DG sets complete all as specified and directed by Engineer-in-Charge.
M&L for painting of DG Set for following capacity make kirloskar/cummins/greaves scraping of old Paint and proper cleaning and painting of one coat redoxide and two coat of enamel paint existing colour complete all as specified and directed by Engineer-in-Charge.
500KVA DG Set
280KVA DG Set
160/140KVA DG Set
S&F in replacement of old unsv Off load change over switch of capacity 1000Amps capacity suitable for four pole all as specified and directed by Engineer-in-Charge. Make: Havells/Hager/L&T
Supply and fixing in replacement off load changeover switch 850 Amps, 4 pole in sheet metal enclosure, side /front handle operated, cat No IHCFFE0630 Make-Havells or equivalent of L&T/Legrand complete all as secified and directed
Supply and fixing in replacement off load changeover switch 630 Amps, 4 pole in sheet metal enclosure, side /front handle operated, cat No IHCFFE0630 Make-Havells or equivalent of L&T/Legrand complete all as secified and directed
Supply and fixing in replacement off load changeover switch 400 Amps, 4 pole in sheet metal enclosure, side /front handle operated, cat No IHCFFE0630 Make-Havells or equivalent of L&T/Legrand complete all as secified and directed
Supply and fixing in replacement off load changeover switch 200 Amps, 4 pole in sheet metal enclosure, side /front handle operated, cat No IHCFFE0630 Make-Havells or equivalent of L&T/Legrand complete all as secified and directed
Supply and replacement of old unserviceable Battery 12V 180AH with complete all as specified and directed by Engr-In-Charge
Supply and replacement of old unserviceable Battery 12V 150AH with complete all as specified and directed by Engr-In-Charge
-BLANK-
Supply, Laying, in replacement of underground cable ISI marked PVC insulated heavy duty electric cable armoured and PVC sheated heady duty 1100 volts grade with aluminium conductor multistranded including cable connectng lugs , glands, jointing material ete, laid in trenches, floor, ducts and fixing on pole, wall complete of size 630 Sqmm 3.5 Core complete all as specified and directed. Make- Gloster/Havells/ Polycab/ Finolex.
Supply, Laying, in replacement of underground cable ISI marked PVC insulated heavy duty electric cable armoured and PVC sheated heady duty 1100 volts grade with aluminium conductor multistranded including cable connectng lugs , glands, jointing material ete, laid in trenches, floor, ducts and fixing on pole, wall complete of size 630 Sqmm 3.5 Core complete all as specified and directed. Make- Gloster/Havells/ Polycab/ Finolex. 400 Sqmm 3.5 Core. Make- Gloster/Paragon/Havells.
Supply, Laying, in replacement of underground cable ISI marked PVC insulated heavy duty electric cable armoured and PVC sheated heady duty 1100 volts grade with aluminium conductor multistranded including cable connectng lugs , glands, jointing material ete, laid in trenches, floor, ducts and fixing on pole, wall complete of size 300 Sqmm 3.5 Core. Make- Gloster/Paragon/Havells.
Supply, Laying, in replacement of underground cable ISI marked PVC insulated heavy duty electric cable armoured and PVC sheated heady duty 1100 volts grade with aluminium conductor multistranded including cable connectng lugs , glands, jointing material ete, laid in trenches, floor, ducts and fixing on pole, wall complete of size 240 Sqmm 3.5 Core. Make- Gloster/Paragon/Havells
S & F in replacement MCCBs 415 Volt 4 pole C Frame Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 200 Amps complete all as specified and directed by Engineer-in-Charge. Make:Havells/ Legrand/Hager/L&T
S & F in replacement MCCBs 415 Volt 4 pole C Frame Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 250 Amps complete all as specified and directed by Engineer-in-Charge. Make:Havells/ Legrand/Hager/L&T
S & F in replacement MCCBs 415 Volt 4 pole C Frame Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 400 Amps complete all as specified and directed by Engineer-in-Charge. Make:Havells/ Legrand/Hager/L&T
S & F in replacement MCCBs 415 Volt 4 pole C Frame Adjustable thermal & adjustable Magnetic Setting with breaking capacity 50KA 630 Amps complete all as specified and directed by Engineer-in-Charge. Make:Havells/ Legrand/Hager/L&T
Note : Make of spare parts to be replaced under this work and mentioned in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of DG sets and other equipments.
HEENA CONSTRUCTION CO
national engineering
M/S NANCY ENTERPRISES
PADMA ENTERPRISES
R B TRADERS
EESSI
Horizon Construction Company
M/S TRADE LINK
M/S ASHRAF CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .