Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹12.8 L+₹1.1 L (9.61%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹17.0 L+₹5.3 L (45.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
29 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt Pin-144005
Please refer tender documents
2021_MES_426958_1
CA NO. CWE/JAL/K-85/2020-21 8320/85/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class E Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer Kapurthala
₹42,000
Yes
15 May 2021
1 Mar 2021
31 Mar 2021
1 Mar 2021
29 Mar 2021
15 Mar 2021
60 days
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep and getting out in soft/loose soil complete all as specified.
M&L for demolition of brick work built in cement mortar including all quoins arches, pillars etc including dressed stone work and precast concrete articles complete all as specified and as directed
M&L for demolition of cement concrete (un-reinforced) in ground floor and pavings not exceeding 15 cm thick above or below ground level complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed
Dismantling wall and ceiling boards any thickness, including cover fillets complete all as specified and as directed
Dismantling, mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of asbestos cement (Corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and as directed.
Taking down cement or cement lime plaster of any description on brock or stone walls, etc incl raking out joints hacking for keys srubbing down with water etc complete all as specified and as directed.
Taking down chowkats or frames with Shutters ( without taking off the shutter from the frame ) of area n.exc 1.50 Sqm each and removing from site complete all as specified and as directed.
Returning ,filling in including spreading, levelling,watering and ramming in layers n. exc 25 cm thick each complete all as specified and directed by Engr-in-Charge.
Removal of surplus soil to a distance n.exc 50 m & depositing where directed at a level n. exc1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub Class'B' bricks straight or curved on plan to any radius using old size bricks and built in CM 1:6, complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick cement plastering in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified.
M&L for 15 mm thick cement plastering in cement mortar (1:4) of brick work or concrete surfaces with using water proofing compound finished even & smooth without using extra cement complete all as specified.
M&L for 5 mm thick rendering in cement mortar in 1:3 on ceiling surface and concrete surfaces complete all as specified and as directed
M&L for applying 3mm thick wall care putty on wall complete all as specified and as directed.
Material & labour for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical, for rough finished concrete surfaces complete all as specified and directed by the Engr-in-Charge.
M&L for form work to soffits of suspended slab on flat surface of such as roof slab n. exc 200mm thick (horizontal or sloping ) with rough finished concrete surface complete all as specified
M&L for formwork to flat surface of sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for formwork to sides of pillars, columns and stanchions as rough finished concrete surfaces complete all as specified and directed.
M & L for PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation complete all as specified and directed by Engr-in-Charge.
M & L for TMT bars 10 mmm dia and over dia cut to length bent to shape required including cranking, bending and binding with and including MS wire (annealed) n. less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No. 22 above but 6mm to 8mm dia. complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded aggregate as in foundations, including raft footings, foundation beams, bases for columns, etc.complete all as specified
M&L for RCC M-25 (design mix) using 20 mm graded aggregate aggregate as in columns, pillars, piers, posts and struts etc complete all as specified
M&L for RCC M-25 (design mix) using 20 mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified
M&L for RCC M-25 (design mix) using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified
M&L for 605mmX605mm size anodised aluminium snap grid frame work for false ceiling with aluminium angle 25X25X1.5mm thick and Tee 25X35mmX1.5mm thick and using 2mm GI wire adjustable as suspender in required length complete all as specified and as directed.
M&L for gypsum waterproof board 12mm thick in ceiling fixed with screw and surface finishes by applying two coats of oil bound distemper over a coat of primer complete all as specified as per manufacturer instructions.
Supply & fixed sliding/opening anodised aluminum door/window shutters including frame,and made out of hollow extruded alumimum sections as mentioned below. Each door having 02 Nos D type handles, 02 Nos aluminium tower bolts 200 mm size, hydraulic door spring. Shutter to be partly glazed with 5mm thick, plain or tinted glass and partly panelled with 12 mm thick prelaminated particle board fixed with glazing clips, rubber beading / gasket, anodized aluminum beading, screws including bothside openable in door bottom hydraulic double action machine complete all as per specified and directed. Chowkat / frame 101.60 x 44.45 x 1.60 mm thick, shutter top and bottom rail : 114.30 x 44.45 x 1.55 mm thick, Shutter middle rail 83.50 x 44.45 x 1.55mm, Shutter verticle style : 85 x 44.45 x 1.55 mm thick. complete all as specified and as directed.
S&F floor door stopper aluminium alloy body and tongue 140mm anodised with hard drawn steel spring etc complete all as specified and as directed by engineer-in-charge.
S&F as in repairs galvanized mild steel wire cloth 0.56mm dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staple complete all as specified and as directed by engineer-in-charge.
S&F 3mm thick sheet glass ordinary quality glazing with oil putty in square n.exc 0 .5sqm in each pane complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet padestal pattern( white ) includng trap health faucet ,seat cover, fixing bolts, flushing cistern, toilet paper holder vitreous china box type and flush pipe complete all as directed.
S&F in repairs vitreous china urinals, flat back of size 465mmX355mmX 265mm, white with grating and union for discharge pipe including connecting to waste pipe complete all as specified and directed.
Supply & fix in repairs wash hand basin vitreous china coloured, flat back, size 550 x 400 mm with a set of CI brackets, brass chromium plated waste fittings and PVC waste pipe 32 mm bore, including chinaware pedestal for waste pipe, connection to water tubing, PVC connection 15mm dia with brass check nuts incl CP 15mm pillar tap complete all as specified.
S&F in repair 15 mm bore dia bib tap fancy type chromium plated (long or short body) cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for union and concealed complete all as specified and as directed by engineer-in-charge.
S & F harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
S&F in repair 15 mm bore stop valve fancy type chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for union with long shank and cup (concealed type) screwed both ends for iron pipe etc complete all as specified and as directed by engineer-in-charge.
S&F in repair 15 mm bore brass CP WHB mixer for hot and cold water screwed down for iron pipe etc complete all as specified and as directed by engineer-in-charge.
S&F in repair towel rail 600mm long of PTMT incl CP brass screws and wooden/plastic cleats (Minimum weight 190 gms) complete all as specified.
M&L for preparing new surfaces of ceilings and applying two coats of oil bound distemper over a coat of primer complete all as specified
M&L for preparing surfaces of new walls and applying two coats of oil bound distemper over a coat of primer complete all as specified.
S&F PVC SWR pipe 110 mm dia fixed to walls, single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed.
S&F in repairs 100 dia PTMT grating doom (min wt 25 gms) complete all as specified.
S&F in repairs 110 mm dia stack clamp made out of 25x4mm flat iron etc complete all as specified
M&L for vitrified ceramic dark shade tiles 10mm thick (square/rectangular ) polished, area of each tiles exceeding 0.42 sqm not exceeding 1.0 sqm in floor etc ,set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over and including 20 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic colour tiles of size 300mmx200mm x 7mm thick on vertical surfaces such as in skirting, dado etc over and including 10 mm thick backing coat in CM 1:4, complete all as specified and directed.
M&L for 25mm thick cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate as in levelling course complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in filling and mass concrete complete all as specified and directed.
M & L for 100mm thick cement concrete type D–2 (1:4:8) using 40mm graded stone aggregates as in sub base of floor complete as specified and directed by Engineer -in -Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in–Charge. Note: Punned down thickness shall be measured
M & L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement and with pigment complete all as specified and directed by Engr - in - Charge.
M & L for cement concrete 1:2:4 type B–1 using 20mm graded stone aggregates as in copings, finishing side to path, including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer - in - Charge .
M&L for 20-25 mm thick machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, over and including 20 mm thic screed or bedding layer in CM 1:4 complete all as specified and directed by Engineer - in - Charge .
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer - in - Charge
M&L for preparation of old decorated brick/concrete plastered or unplastered surfaces of walls including pillars, cornices etc booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, graeacy spots etc incl removal of existing treatment and applying a coat of exterior emulsion paint (Apex) on external surface of wall over and including one coat of cement base primer complete all as specified.
M&Lfor preparing surfaces of new walls and applying two coats of exterior emulsion paint (Apex) over a coat of primer complete all as specified
Dismantling brick tile or terracing tile single layer on roof complete all as specified and as directed by engineer-in-charge.
Demolition of mud in roofs any thickness including plastering and leeping (weather full thickness removed or part there of) complete all as specified and as directed by engineer-in-charge.
M&L for 50mm average consolidated thickness PCC 1:3:6 type C2 with using 40mm graded stone aggregate as in padding on flat roofs etc complete all as specified and directed.
Supply only Integral water proofing compound conforming to IS-2645complete all as specified and as directed by engineer-in-charge.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm over and including a coat of primer 0.4ltr/sqm including cleaning surfaces complete all as specified and as directed by engineer-in-charge.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick, reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application complete all as specified and as directed by engineer-in-charge.
M&L for 40mm thick brick tiles laid on 15 mm thick cement mortar bed ( 1:6) with WPC and joints grouted flush in cement mortar (1:6) mixed with 5% of crude oil by weight of cement and pointed in CM (1:3) complete all as specified and as directed by engineer-in-charge.
All as per item No. 66 above but except brick tiles complete all as specified and as directed by engineer-in-charge
M & L for flush pointing to bricks laid flat or brick tiles in pavings in CM 1:3 complete all as specified and as directed by engineer-in-charge.
M&L for providing, cement concrete type B2 (1:2:4) (using 20 mm graded stone aggregate), as in roof kerbs or mud stops, rounded or chamfered on edges parapets copings, bed plates, etc complete all as specified and as directed by engineer-in-charge
M&L for cutting grooves of size 75mm wide and 65mm deep in brick parapet wall for inserting APP membrane and making good the disturbed portion in CM (1:3) complete all as specified and as directed by engineer-in-charge
S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with J type hooks complete all as specified and as directed by engineer-in-charge
S&F transparent/figured Sheet glass 6.3mm thick exc 0.5 Sqm in each pane including fixing with door or windowetc complete all as specified and as directed by engineer-in-charge
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staple complete all as specified and as directed by engineer-in-charge.
Taking down carefully existing point wiring of any type (i.e. wooden surface conduit casing capping or concealed conduit) complete for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, sockets, lights fitting, regulator, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Material & labour for concealed point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated and unsheathed cable 1100 volts multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit not less than 20mm dia bore medium grade (ISI marked) and accessories like bends, tees, junction boxes etc, fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS, copper multistranded cable as earth wire including sunken pressed steel terminal boxes and bakelite white/ coloured top sheet cover 3.0 mm thick , for One light point / fan point controlled by one way switch complete all as specified and directed.
All as per srl item No 75 here-in-before but 3 pin switch socket outlet, 5 Amps on independent board complete all as specified and as directed
All as per srl item No 75 here-in-before but for 3 pin socket outlet, 5 Amps on same board with other switches complete all as specified and as directed
All as per description of srl item No 75 here in before but using 2.5 sqmm (nominal area) PVC unsheathed cable independent including PVC cable copper conductor with 2.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor and connecting for earth dolly for 5 pin socket out let 15 Amps on independent board. complete all as specified and directed
S&F modular switch 6 amp, 230 volts AC, one way, one module complete all as specified and directed.
S&F modular switch 20 amp, 230 volts AC, one way with indicator, one module complete all as specified and directed.
S&F modular socket 6A, 2/3 pin two module combined complete all as specified and directed.
S&F modular socket 16A, 2/3 pin two module combined complete all as specified and directed.
S&F modular fan regulator stepped type, 120W, 2 module complete all as specified and directed.
S&F white colour plates with frame for modular switch of 3 module complete all as specified and directed.
S&F white colour plates with frame for modular switch of 4 module complete all as specified and directed.
S&F white colour plates with frame for modular switch of 6 module complete all as specified and directed.
S&F white colour plates with frame for modular switch of 8 module complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite 65 x 50 mm three terminal PVC / Polycarbonate isolated body(ISI marked) complete all as specified.
Supply, installation, testing and commissioning of 20 watt 4 ft long LED batten housing made of self ballasted LED batten extruded aluminium with PC diffuser and inbuilt electronic driver system more than 120 degree wide light distribution lumen output should be at least 1800 lumen with a CCT of 6500K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. Make:Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS or equivalent makes as in Appx 'B'
Supply, installation, testing and commissioning of 2" x 2" LED fitting, 36 watt super bright LEDs with highly efficient light smoothing optis to deliver superior illumination and energy saving suitable for surface/recess mounted complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. Make:Polycab Cat Part No PETAL2X2PLR36WLED840S or equivalent makes as in Appx 'B'
S&F lamp holders, with PVC insulated body fixed plastic laminated sheet cover shape 3mm thick suitable for batten fitting including 01 No. of LED 1 x 15 Watt, 230 Volts suitable for 230 volt AC complete all as specified and directed.
Supply and fixing of ceiling fan 1200mm sweep completed with capacitor and down rod including flexible twin core copper (23/0.0076) with provision of ceiling rose connector to fan complete all as specified and directed.
M&L for MCB SP with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts and 6 to 32 amps current rating 'B' series, 10 KA complete all as specified and directed.
M&L for MCB SPN with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts and 6 to 32 amps current rating 'B' series, 10 KA complete all as specified and directed.
M&L for MCB TPN with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for three phase circuit of 415 volts and 63 amps,10 KA complete all as specified and directed.
Supply and fixing sub main wiring with two single core PVC insulated cable with copper conductor stranded and sheathed of size 2.5 sqmm, two runs in and including PVC concealed conduct medium grade of size not less than 25mm dia including PVC accessories complete incl cutting and chasing and making good etc incl one run of 2.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed.
S&F double door distribution board class IP-43 with 200 amp rated copper bus bar 240 V, 8 way single pole and neutral link , suitable for mounting incoming and outgoing MCBs double pole/single pole complete all as specified and directed. Note: Incoming and outgoing MCB SP/DP will be measured and paid separately
S&F double door distribution board class IP-43 with 200 amp rated copper bus bar 240 V, 4 way triple pole and neutral link , suitable for mounting incoming and outgoing MCBs double pole/single pole complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to galvanised strip lead 32 x 6 mm earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) type C1 using 20mm graded stone aggregate and 40mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed. .
AAY KAY Constructions
SUNRISE CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .