| 1 | L1₹22.9 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹28.7 L+₹5.1 L (21.5%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
20 Oct 2022, 6:00 pmClosed
Major A R Thakkar
GE (P) Dappar
Special Repair to wiring in Bldg No 83 84 100 at Mil Stn Dappar under GE (P) Dappar
2022_MES_553488_2
GE (P) DPR-21/2022-23
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹95,000
Yes
16 Dec 2022
4 Oct 2022
22 Oct 2022
4 Oct 2022
20 Oct 2022
4 Oct 2022
4 Oct 2022 - 4 Oct 2022
Amount
Taking down carefully Copper/aluminium point wiring on wooden batten /pvc conduit /Pvc casing and capping (light/Socket/Power) complete including (Fittings such as switches, ceiling roses, pendants, regulators, sockets electric energy meters, light fittings, etc to be measured separately) removing materials to store and making good distrubed surfaces of walls. Floors etc to match with the existing including disconnection of ceiling/exhaust fan connection, complete all as specifed and directed by Engr-in charge.
Taking out existing sub main wiring of any description and size including earth wire incld wooden battens/ conduits/quities from stone/brick masonry walls, roofs, floors, MCB/MCCB distribution board etc. all as directed by Engr-In- Charge.
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic ISI marked PVC conduit of not less than 20 mm dia, thickness 1.8 mm, concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes, etc. concealed in walls suitable for mounting modular switches, sockets, etc and including FRLSH PVC insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:- Note:- Switches , sockets, ceiling rose, regulators, etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting conduit, SUNKEN BOXES, ETC. and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
(a) One light / fan / Bell point controlled by one switch
(b) all as per above but in Casing caping, with bend and elbow etc
(c) One light point controlled by two way switch
(d) One 5 pin socket outlet independent 5 Amps
(e) One socket outlet 5 Amps on the same board with other switches.
(f) One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and 2.5 sqmm copper cables as earth wire.
M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4.0 sqmm (line conductor) & 1x4.0 sq mm (earth conductor), 1100 V grade drawing in & including heavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
All as per above but in existing PVC conduit with single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x1.5sqmm and 1 x 1.5 sqmm.
M&L of FRLS PVC insulated & PVC sheathed industrial round multicore flexible copper conductor cable, 1100 volts to be drawn in non-metallic PVC Cable trunking (PVC cable trunking will be measured & paid seperately under relevant item of this schedule) of size 3x4.0 sqmm fixed on wall complete all as specified and directed. Note : (i). Cost of suitable size copper cable lugs is deemed to be included in the quoted rate only. (ii). Cost of cutting chases in wall for flush fitting of conduits/cable trunk and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
All as per above but FRLS PVC insulated unsheathed multistranded copper conductor cable of size 3x2.5 sqmm.
All as per above but FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4x4.0 sqmm.
All as per above but FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4x6.0 sqmm.
All as per above but FRLS PVC insulated unsheathed multistranded copper conductor cable of size 2x1.5 sqmm.
M&L for fixing of fire retradant, smooth fixished, thermally stable, Casing-Casing type PVC Cable trunking including all necessary acccessories to be fixed on wall of size 100x100mm strictly adhering to IS-14927 Part 2 standards and all as directed by Engr-in-charge of Make Pressfit Cat Part No. 113061 or equivalent in Finolex/Modi. Note: (i) Quoted rate is deemed to be inclusive of all suitable size PVC trunking accessaries like elbow, couplng, Tee, Juncton box etc. The accessories must be of same Make as that of PVC cable trunking. (ii) Cost of all type of minor jobs for fixing of PVC cable trunking is deemed to be included in the quoted rate.
S&F Modular switch 1 way 6 A, 1 module type single pole 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand (Myrius)
S&F Modular switch 2 way 6 A, 1 module type single pole 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular socket 6Amps 2/3 pin combined 2 module 240 Volts complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular socket 6/16Amps 2/3 pin combined 2 module 240 Volts complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular switch 16Amps 2/3 pin combined 2 module 240 Volts complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Bell push 6 Amps 1 module 240 volts complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Fan step regulator, 120 w-2 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F White cover plate with frame 2 module 240 volts complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F White cover plate with frame 4 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F White cover plate with frame 6 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F White cover plate with frame 8 module 240 volts andcomplete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F White cover plate with frame 12 module 240 volts andcomplete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Metal Box 2 module and complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Metal Box 4 module and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Metal Box 6 module and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Metal Box 8 module and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
S&F Modular Metal Box 12 module and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius)
Supply and fixing in replacenment Modular Angle holder Cat Pat No. 39935 of Anchor or Equivalent in M/s Havells/SSK with insulated body with back plate for LED lamps all as specified and directed by the Engr-in-charge.
Supply and fixing in replacement LED lamp 9 watt, retrofit all as specified and directed by Engr-in-charge. MAKE : CROMPTON /HAVELLS/Philips
S&F in replacement LED tube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge. MAKE : CROMPTON /HAVELLS/Philips
Supply and fixing in replacement ceiling rose bakelite, 63.5mm 3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-charge.
S&F for wall flush mounting Sheet metal enclosure MCCB TPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 415V, 6 way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. Make : Legrand/ABB/Schenider. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
S&F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge.
S&F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA, 'C' series 240 V ISI marked complete all as specified and directed by Engr-in-charge. MAKE : Legrand/ABB/Schenider
S&F for wall flush mounting of Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. Make : Legrand/ABB/Schenider. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
All as per Item No. 43 above but Sheet metal enclosure MCB SPN distribution board but 4 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed.
All as per Item No. 43 above but Sheet metal enclosure MCB SPN distribution board but 12 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed.
All as per Item No. 43 above but Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 16 Way with shrouded neutral bar
All as per Item No. 43 above but Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 18 Way with shrouded neutral bar
All as per Item No. 43 above but Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 20 Way with shrouded neutral bar
All as per Item No. 43 above but Sheet metal enclosure MCB TPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 4 Way, Double door with shrouded neutral bar
Supply and fixing MCB SPN 32-63 Amps,10 KA 'C' series 240 V ISI marked complete all as specified and directed by Engr-in-charge. Make: Legrand/ABB/Schenider
Supply and fixing in replacement MCB TPN 63 Amps, 10 KA 'C' series 415 V ISI marked complete all as specified and directed by Engr-in-charge. MAKE - Legrand/ABB/Schenider
Supply and fixing in replacement MCB TPN 40 Amps, 10 KA 'C' series 415 V ISI marked complete all as specified and directed by Engr-in-charge. MAKE - Legrand/ABB/Schenider
Supply and fixing in replacement mirror light fitting LED 10W, 230 V, 2ft all as per Crompton Make Cat No. - LCL-14-CDL or equivalent in Philips/Wipro complete all as specified and directed by Engr-in-charge.
M&L for Taking down ceiling fan and connected cables removing it to safe place and Re-Fixing ceiling fan and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed by Engr-in-charge.
M&L in replacement bell Ding Dong AC, 230 V single pole all as specified.
M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.0 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary suitable dia. and 1.0 mtr long bracket made out of GI pipe with clamp, nuts and bolts for mouting complete all as specified. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
Supply and fix PIR Occupancy Sensor wall Mount 3-wire, 180-210 degree, switch board snap fitting, adjustable detection distance from 3 to 10m including suitable size modular metal box, modular PVC frame etc in 2 Module with suitable metal box all as specified and directed by engr-in charge.
Supply and fix in replacement 3 module Modular flush mounting type AC Box with 20A SP MCB, including unbreakable Heavy Duty with ISI Plug top all as per Havells Make Cat Part No DHDDCDP025202003 or equivelant in Anchor/Schneider/Legrand complete all as specified and as directed by Engr-in-Charge
Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 16 sqmm x 2.0 core to be fixed on wall all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (b). The cost of saddling of cable to wall using appropriate size of MS clamps, etc. alongwith suitable size and type of aluminium lugs is deemed to be included in the quoted rate.
Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 70 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (b). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.
Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge.
Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm.
S&F Light fitting pre wired 28 watts LED 2X2 recess mounting luminaire ceiling light fitting complete with driver and all accessories directly on ceiling/wall including connection with 1.5 sq mm PVC insulated copper wire, complete all as specified. Make: Havells Cat no. PLUTONE02X2PLR28WLED840S or equivalent in WIPRO/PHILIPS
Supply & Fix in replacement only Rigid non meatalic PVC conduit heavy duty 25mm dia ISI marked with all accessories and fittings on surface of wall, ceiling and making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge.
HARISH SALES CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .