| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.2 L+₹94,385 (9.22%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance other than L1 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
25 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
DAY TO DAY E/M MAINTENANCE SERVICE TO DOMESTIC AREA AT AIRFORCE STATION THANJAVUR
2022_MES_510426_1
8857/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANJAVUR
AS PER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹28,000
Yes
18 May 2022
25 Feb 2022
26 Mar 2022
25 Feb 2022
25 Mar 2022
11 Mar 2022
60 days
Amount
Taking down carefully old aluminium/copper point wiring for one light, socket or power etc including all fitings such as switches, sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall ceiling complete all as specified.
Point wiring complete with 1.5 Sq mm PVC insulated cable with copper conductor 1100 Volts grade, multistranded in and including PVC conduit and condiut accessories of 20 mm dia concealed on walls, roof etc with and including provn of 1.6mm thick MS terminal boxes concealed/surface in walls with 3 mm thick laminated hylam sheet top cover for fixing switches, switch sockets outlets etc including provn of 1.5 Sqmm multistranded copper conductor cable PVC insulated unsheathed as earth continuinity cable for one light point controlled by one switch complete all as specified.
All as per item No 2 mentioned here-in-before but for One fan point controlled by one switch and regulator complete all as specified.
All as per item No 2 mentioned here-in-before but for One socket outlet 3 pin 5 amps on same board complete all as specified.
All as per item No 2 mentioned here-in-before but for One socket outlet 3 pin 5 amps on independent board complete all as specified.
All as per item No 2 mentioned here-in-before but for One bell point controlled by one switch complete all as specified.
All as per item No.2 above but with 4 sq mm cable for one 3 pin 15 amps switch socket outlet on independent board with 4 sq mm cable for earth wire drawn through and including 20mm dia PVC conduit and accessories all as specified and directed
Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor including PVC rigid non metallic 25 mm PVC casing caping (double Lock) including PVC polycarbonate / PVC/rectangular block/box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross sectional area PVC insulated unsheathed single core multistranded copper conductr cable as earth continuity conductor connected to one light point controlled by one switch complete all as specified.
All as per item No 8 mentioned here-in-before but for one ceiling fan / Exhaust fan point, controlled by one way switches 5/6 Amps complete all as specified.
All as per item No 8 mentioned here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the independent board complete all as specified.
All as per item No 8 mentioned here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the same board with other switches complete all as specified.
All as per item No 8 mentioned here-in-before but for one bell/buzzer point controlled by one bell push button on independent board complete all as specified.
All as per item No 8 here-in-before but for point wiring with 4 Sq mm (nominal cross sectional area) single core stranded copper conductor for one switch socket out let point, 15/16 amps on the independent board complete all as specified.
Fixing only old serviceable tube light fittings of any type complete all as specified. Note : Old serviceable light fittings shall be obtained from taking down of ser item No 1 here-in-before.
Lamp holder, insulated body, with back plate suitable for battern fittings/pendent fittings white/ivory finish complete all as specified.
Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified.
Fixing only Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified. Note : Old serviceable switch shall be obtained from taking down of ser item No 1 here-in-before.
Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified.
Ding dong bell, AC, Single pole, 220/240 Volts, white/ivory finish, surface type complete all as specified.
Switch socket combination, 2 and 3 Pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type white/ ivory finish complete all as specified.
Switch socket combination, 2 in 1, 6 pin, 5/6 amps and 15/16 amps multipurpose, white/ivory finish, flush non shutter, non inter locking type complete all as specified.
Switch, modular type, 1 module, one way, 6 Amp complete all as specified.
Switch, modular type, 1 module, one way, 16 Amp complete all as specified.
Switch, modular type, 1 module, two way, 6 Amp complete all as specified.
Bell push, modular type, 1 module, one way, 6 Amp complete all as specified.
Socket 2/3 pin , modular type, 2module, 6Amp complete all as specified.
Socket 2/3 pin , modular type, 2module, 16Amp complete all as specified.
Fan regulator step type, modular 120 watt, 2 module complete all as specified.
Modular white cover with frame 1 module complete all as specified.
Modular white cover with frame 3 module complete all as specified.
Modular white cover with frame 4 module complete all as specified.
Modular white cover with frame 6 module complete all as specified.
Modular white cover with frame 8 module complete all as specified.
Metal flush box, modular type, 1/2 module complete all as specified. .
Metal flush box, modular type, 3 module complete all as specified.
Metal flush box, modular type, 4 module complete all as specified.
Metal flush box, modular type, 6 module complete all as specified.
Metal flush box, modular type, 8 module complete all as specified.
Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, SPN with 200 amps rated bus bar, IP-20 protection suitable for fixing MC's/lsolators including taking down old DB with MCB complete all as specified.
Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, SPN with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators after and including taking down old DB with MCB complete all as specified.
Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, SPN with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB,s/lsolators after and including taking down old DB with MCB complete all as specified.
Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, TPN with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB's / lsolator’s after and including taking down old DB with MCB complete all as specified.
Ceiling rose, surface Bakelite, large type, 220/240 volts, three terminals, white/ivory finish complete all as specified.
Fan regulator electronic type suitable for 300 Watt (heavy duty) type 250 V, AC for ceiling fan complete all as specified.
Sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified.
Sub main wiring with 2 run of 6 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified.
Supply and fixing in replacement of wall mounted LED Batten 20 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified.
Supply and fixing in replacement of wall mounted LED Batten 10 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified.
Supply and fixing in replacement 2 x 2, 42 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete all as specified.
Supply and fixing in replacement 1 x 1, 15 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete all as specified.
Supply and fixing in replacement 36 Watt LED ceiling light fitting 4 x 1 feet suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete all as specified.
Supplying and fixing in replacement of 10W, IP66 environmental friendly, ultra modren energy saving surface mounted decorative hexagonal bulk head back lit LED luminaries comprising of high brightness LEDs and making necessary connections complete all as specified.
MCB, Triple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified.
MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified.
MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified.
MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified.
LED Bulbs of 15 Watt, B-22 base Cap complete all as specified.
LED Bulbs of 9 Watt, B-22 base Cap complete all as specified.
Dimantling and taking out ceiling fan 230 volts 1200/1400mm sweep any make cutting the old burnt winding, rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating Varnish, lathe work, replacement of 2.25/3.15 MFD capacitor, replacement of MS split clamp 02 nos with rubber reel and painting after completion of rewinding process complete all as specified.
Dismantling and taking out carefully ceiling fan of any size and capacity, supply and fixing in replacement of ball bearing of size 6200 to 6204 suitable for ceiling fan 1200/1400mm sweep with out disturbing to winding complete all as specified.
Dimantling and taking out Exhaust fan 230 volts 200 to 450mm sweep any make cutting the old burnt winding, rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating varnish, lathe work, replacement of capacitor, replacement of gun metal bushes and painting after completion of rewinding process complete all as specified.
Supply and fixing in replacement heating element any size, shape of capacity 1.5/2 KW 230 volt AC supply for electric storage type water heater complete all as specified.
Supply and fix in replacement inner MS water storage tank suitable for 15 ltr storage type water heater complete all as specified.
Supply and fix in replacement inner MS water storage tank suitable for 25 ltr storage type water heater complete all as specified.
Supply and fix in replacement inner MS water storage tank suitable for 50 ltr storage type water heater complete all as specified.
Supply and fix in replacement thermostat of capacity suitable for 1.5/2 KW 230 volt AC supply for electric storage type water heaters any size/shape complete all as specified.
Supply and fixing in replacement inlet outlet assembly any size/shape/Nos of holes suitable for 15 to 50 ltr electric storage type water heaters complete all as specified.
Supply and fix in replacement single pole and neutral enclosure with two pin and earth plug and socket complete with single pole MCB 32 amps capacity complete all as specified.
Supply and fix in replacement fan capacitor 3.15 MFD complete all as specified.
Supply and fix in replacement electronic driver suitable for LED ceiling lights 36/18 watt complete all as specified.
Supply and fix in replacement MCCB 100 amps 3 pole 415 volts 50 HZ AC Supply ICU=ICS=100% 16 KA complete all as specified.
Labour only for taking out of any DB's of any make for attending NO light /Earth leakage complaints from technical area and disconnecting the wires/cables from terminal blocks and connection to feeder and cutting/removing the damaged worn out conductor/wires portion and reconnecting the cable to terminal box after servicing and making serviceable condition, testing complete all as specified. Note:material used for making serviceable condition will be measured seperately.
Note For Day to Day maintenance:- (i) The contractor will be alloted complaint on daily basis and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 hrs from the time of reporting.Any delay beyond above mentioned time limit penalty at the rate of Rs.100 per complaint per day shall be levied (ii) A detailed log of complaints with completion/non completion remarks from users & MES will be maintained by the contractor and same will be updated on daily basis in consultation with Engineer In Charge or JE detailed by him duly signed. (iii) The contractor will make suitable arrangement for emergent complaints and will notify auth rep/Engr In Charge about extraordinary circumstances for probable non completion or delay in rectification of complaints beyond stated time limit set for disposal complaint in case of any dispute the decision of accepting officer shall be final and binding. (iv) The quoted rate deemed to be incluisive of transportation and other expenses required for the resourse deployment at the complaint site at Airforce station thanjavur. (v) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically by Engineer In Charge to streamline complaints disposal system (vi) No light/earth leakage complaints has to be attended immediately and feed back to be get from user and intimated to Engineer In Charge or JE detailed by him duly signed.
BKR Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .