| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.8 LAccepted-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | 1 | Accepted-AOC LOWEST RATE | |
| 2 | 2₹36.2 L+₹3.4 L (10.3%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹37.6 L+₹4.7 L (14.4%)Rejected-Finance 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹37.8 L+₹4.9 L (15.0%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹38.1 L+₹5.3 L (16.1%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38.9 L
EMD Value
₹77,820
Closing Date
8 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT - 110010
PROVN OF DRAIN WITH GRADIENT AND SLOPE AND OTHER B/R AND E/M WORK IN 1 AFDC AT AF STN PALAM UNDER GE(AF) PALAM DELHI CANTT-10
2023_MES_579833_2
GENP-70/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹77,820
Yes
20 Apr 2023
8 Feb 2023
9 Mar 2023
8 Feb 2023
8 Mar 2023
23 Feb 2023
Amount
B/R WORK Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for foundtion or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil.
Returning filling in including sprading levelling watering and well ramming in layers not exceedng 25cm thick complete.
Removal of excavated material/soil to a distance exc 100 m and not exc 150 m and depositing where directed at a level n exc 1.50m above the starting point.
M & L for cement concrete type C-2, 1:3:6 (Using 40mm graded stone aggregate) as in foundations, filling and mass concrete.
M&L for brick work with sub class 'B' bricks in cement morter 1:4 straigth or curved on plain exc 6m mean radius complete.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, bed plates, wall through and the like including weathering slightly rounded or chamfered angles and threading and necessary form work.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4 including finished even and fair surface without using extra cement.
S&F for SFRC drain cover size1000mm x 500mm x 70mm thick laid over existing drain complete all as specified and as directed by Engr-in-Charge.
M&L for reinforced cement concrete M-25 (design mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surface complete.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished flat surface complete.
M&L for 300mm bore reinforced concrete pipes, class NP-2, laid and jointed complete with collars .
Excavation in post holes (or similar holes) not exc. 0.50 Cum each in soft/loose soil and getting out returning filling in and removing surplus spoil to a distance not exc. 50.00 m and make good the surfaces, complete all as specified and as directed.
M&L for rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410 -W (GdeE- 250) quality including all necessary welding, bending etc complete all as specified and as directed.
M&L for rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410 -W (GdeE- 250) quality including all necessary welding, bending complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, filling and mass concrete, fixing posts complete.
S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil.
M&L for hardcore of broken stone of boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L for 100mm thick cement concrete, type D-2, 1:4:8 using 40mm graded stone agreegate as in hardstanding complete.
M&L for 50 mm thick cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) as in floors etc including finishing surface even and fair withort using extra cement.
M&L for factory made machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment laid over 25mm thick sand layer complete.
M&L for factory made machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment laid over 25mm thick sand layer complete.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection and paving with surface finished even and smooth without using extra cement and making 10mm wide groove at every 1.50m and at junction & filled with bitumen mastic all as specified.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290.Gde-E-165.
M&L for preparation of newly steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete.
M&L for preparation of old decorated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F for 1.25 mm thick mild steel, plain, black sheet in wall cladding, steel gates & similar work, cut to size, holes punched including rounded headed screws, clout nails or reverts & fixed to steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc. as required
M&L for providing cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, mass concrete and filiings .
Form work to side of concrete in foundation, footing base, base of columns, side and soffits of plinth beam and simillar work complete all as specified and directed.
M&L M&L for reinforced cement concrete M-25 (design mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
Form work to side of columns and simillar work complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) as in columns and pillars etc complete.
Form work to side of sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, and simillar work complete all as specified.
M&L for reinforced cement concrete M-25 (design mix) as in beams, cantilevers, ressummers, lintels over 1.5m span complete all as specified and directed.
S&Ffor mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No.36 above but 8 to 10 mm dia TMT bar as in stirrups, spacers and binders.
M&L for brick work with sub class B old size burnt bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement morter 1:6 including finished even and smooth surface without using extra cement on wall upto 4th storey bldg and necessary scaffolding complete.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4 including finished even and fair surface without using extra cement upto 4th storey bldg and necessary scaffolding including water proofing compound .(Note: WPC shall be measured and paid separately)
Supply only Liquid water proofing compound of approved quality.
M&L for prepration of newly plastered surface and finishing walls with premium Acrylic Smooth Exterior paint with Silicone additives of required shade with two coats applied @ 1.43 ltr/ 10 Sqm (Make wall mista of berger paint or its equivalent in Asian paint, Nerolac etc having three years of performance warranty) over priming coat of exterior primer applied @ 2.20 kg/10 sqm all as specified and directed.
M&L for granite (of any type) slab 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 15 mm thick screed bed 1:4 as in in floor /wall etc all as specified and directed by Engr-in-charge
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete article complete.
Dismantling of structural steel work of any description and in any position.
Dismantling of stone slab and tiles of any description including cement mortar bedding and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Taking down cement plasterm of any description on brick or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc upto 4th storey bldg and necessary scaffolding including rubbish off the premises complete.
E/M PORTION M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type cast iron or pressed steel terminal box for mounting of modular switches, sockets, fan regulator etc with modular white cover plate with frame for suitable module as per site requirements and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth for One light point controlled by one, one way,SP, 5 Amps switch complete.
All as per item No 48 above but for One socket outlet 5 pin, 5 Amps on the independent board complete.
All as per item No 48 above but for One socket outlet 5 pin, 5 Amps on the same board complete.
S&F for switch piano flush type 5 Amps, single pole one way complete.
Supply and fixing for socket out let 3 pin 5 Amps, flush type complete.
Supply and fixing for ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete.
S & F for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' series complete all as specified and directed.
S & F for LED gate light fitting 25W, IP 65 complete with driver, internal wiring and connection with suitable size copper conductor wire complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 6 Sqmm 2 core in service connections complete.
Supply and fixing for rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reduces, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in wall by cutting and chasing and making good the disturbed surface of wall.
JAIPAL AND BROTHERS
Choudhary Enterprises
DEV CONSTRUCTION
M/S VERMA BUILDER
Kunal Construction Co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .